1 of 3

GE Fanuc PACSystems RX3i IC695NIU001 Ethernet Network Interface Unit

GE Fanuc PACSystems RX3i IC695NIU001 Ethernet Network Interface Unit

Only 3 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC695NIU001

  • Country of origin:United States

  • Product Type: Ethernet Network Interface Unit

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 550g

  • Dimensions: 35 mm x 140 mm x 135 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The IC695NIU001 functions as a high-performance Ethernet Network Interface Unit (NIU) within the PACSystems RX3i control platform series. This dual-width communication module is engineered to enable the remote deployment and automatic execution of standard PACSystems RX3i and Series 90-30 I/O modules across a distributed Ethernet network architecture. Once established via user configuration, data exchange operates completely automatically, allowing system control to be driven by any master device capable of handling Ethernet Global Data (EGD) transfers. The IC695NIU001 continuously delivers diagnostic status markers back to the primary controller during every single data exchange, allowing application logic to dynamically monitor link health and issue real-time commands to the remote chassis. It utilizes basic Ethernet modules (such as the IC695ETM001) mounted in an RX3i Universal Backplane to establish network pathways, supporting secure SRTP TCP/IP communications and seamless integration with high-availability redundancy controllers.

Features

  • Coordinates fully automatic, high-speed remote I/O data transfers over network lines via Ethernet Global Data (EGD) services.
  • Provides 20 Kbytes of selectable local logic memory space supporting standard programming languages (excluding C programming).
  • Embeds 10 Mbytes of non-volatile flash user memory for secure local application data and hardware configuration backup.
  • Features an integrated, battery-backed calendar clock to preserve precise system time logs during host chassis power outages.
  • Incorporates two dedicated onboard serial communication ports (one RS-232 COM1 port and one RS-485 COM2 port) for local peripheral or programmer connections.
  • Supports execution of unique COMMREQ commands issued via Ethernet by C application blocks running in a master PACSystems RX7i or RX3i controller.

Applications

  • Distributed Remote I/O Networks: Extending and centralizing remote PACSystems RX3i and Series 90-30 I/O drops across expansive plant locations.
  • High-Speed Process Synchronization: Utilizing Ethernet Global Data highways to manage fast data exchanges in multi-node continuous manufacturing operations.
  • Infrastructure Redundancy Frameworks: Deploying automated fieldbus interfaces alongside redundancy controllers in mission-critical water, power, or oil and gas utilities.

Technical Specifications

Parameter Value
Manufacturer GE Fanuc (GE Intelligent Platforms)
Model Number IC695NIU001
Series PACSystems RX3i
Product Type Ethernet Network Interface Unit
Local Logic Memory 20 Kbytes (C programming not supported)
Non-Volatile Flash Memory 10 Mbytes
Onboard Serial Ports 1 x RS-232 (COM1), 1 x RS-485 (COM2)
Serial Protocols Supported Modbus RTU Slave, SNP Slave, Serial I/O, Message Mode
Data Exchange Capacity Up to 1300 bytes Input / 1300 bytes Output per exchange
Recommended Battery Pack 3-cell Lithium Battery Pack (IC698ACC701)
Compatible Programming Software Machine Edition Logic Developer version 5.51 or later
Backplane Slot Occupation Dual-width module (occupies 2 standard slots)
Weight 0.55 KG
Dimensions (W x H x D) 35 mm x 140 mm x 135 mm

 

Connections/Interfaces

Port Designation Physical Interface and Function
COM1 (Port 1) 9-pin female D-sub connector, RS-232 signaling; supports WinLoader firmware updates and direct programmer linkages
COM2 (Port 2) 15-pin female D-sub connector, RS-485 signaling; accepts RS-485 to RS-232 adapter (IC690ACC901) connections

 

Installation Guidelines

  • Verify that all incoming electrical power to the RX3i Universal Backplane is completely turned off before inserting or removing the network hardware.
  • Position the unit firmly inside a primary Universal Backplane (IC695CHS0xx) slot 0. As a dual-width module, it occupies two physical slots (typically slots 2 and 3). Do not place it in the rightmost slot of the backplane, as this slot lacks a physical securing latch.
  • Upon turning on rack power and completing internal system initialization, ensure that the front-panel NIU OK LED shines steady green, while the NIU SCANNING I/O and EN LEDs remain unlit until active scanning is configured.
  • To maximize the operational shelf life of the external lithium cell, do not attach the backup battery connector until after the module has been plugged in and powered up for the first time.
  • When executing field maintenance or replacing an exhausted battery, always leave rack power turned on; inserting a new battery pack while the system is completely powered down can trigger a startup fault during the next power cycle.

Compliance and Certifications

  • CSA: Certified by the Canadian Standards Association for safe deployment as industrial process control equipment within ordinary, non-hazardous locations.
  • Factory Mutual (FM): Approved as nonincendive equipment intended for use in Class I, Division 2, Groups A, B, C, and D hazardous environments.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Fanuc PACSystems RX3i IC695NIU001 Ethernet Network Interface Unit

How does the network interface unit exchange data with the central controller?

The device exchanges data over an Ethernet network using Ethernet Global Data (EGD) services. It is typically configured with two individual exchanges: one to receive outputs from the master controller and another to send local inputs back.

What is the correct procedure if the device fails to boot after a battery change error?

If the module fails to power up because a new battery was connected while the rack was entirely powered down, disconnect the battery, perform a full power cycle on the chassis, and then reattach the battery while the system is powered on.

Which industrial fieldbus protocols are supported by the onboard serial ports?

The embedded serial channels natively support Modbus RTU Slave, SNP Slave, standard Serial I/O interface configurations, and raw Message Mode communications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...