1 of 3

GE Mark V DS215SLCCG1AZZ01A LAN Communications Board

GE Mark V DS215SLCCG1AZZ01A LAN Communications Board

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: DS215SLCCG1AZZ01A

  • Country of origin:United States

  • Product Type: LAN Communications Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 18 cm L x 13 cm W x 3 cm H

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The DS215SLCCG1AZZ01A (DS215SLCCG1AZZ01A) is a high-performance network orchestration card engineered for General Electric's Mark V turbine control and heavy industrial drive platforms. Operating under the functional acronym SLCC, this localized processing board coordinates complex local area network (LAN) telemetry, providing an integrated interface plane for large-scale industrial machinery. Crucial infrastructure facilities—including petroleum refining operations, combined-cycle power generation stations, and massive marine compression installations—depend on the DS215SLCCG1AZZ01A (DS215SLCCG1AZZ01A) to sustain uninterrupted communication loops between the main drive controller and peripheral monitoring equipment. Housing both isolated and non-isolated pathways, the module manages synchronous node transitions across dual-protocol networks. This strict data segregation mitigates inductive line noise, ensures high-integrity network synchronization, and prevents catastrophic communications loss that leads to unprogrammed system trips and plant downtime.

Architectural Subsystems & Revision Breakdown

The component architecture and identification scheme of the DS215SLCCG1AZZ01A network card dictate its communication capacity and hardware integration boundaries.

  • Dual-Protocol Control Engine: Centered around an integrated LAN Control Processor (LCP) designated at the U1 position. This processing node governs high-speed data transfers across both DLAN and ARCNET network infrastructures.

  • Socketed Memory Allocation: Employs two independent, field-replaceable EPROM memory chips positioned at slots U6 and U7 to host the LCP operating system files, paired with dedicated high-speed RAM to facilitate real-time drive logic exchanges.

  • Multi-Point Interface Headers: Houses five distinct high-density interconnect sockets: 2PL for centralized power feed distribution, 3PL for direct drive control card interface, 10PL for terminal board lines, ARCPL for specialized network signal routing, and KPPL for handheld keypad interface utilities.

  • Functional Suffix Decoding: The definitive trailing alphanumeric string reveals the assembly build parameters: functional part family SLCC, standard conformal PCB coating code G1, baseline hardware revision A, functional engineering update level Z, artwork layout modification index Z, and system variation subclass identifier 01A.

Technical Specifications

System Index Structural Performance Metric
Model Identity DS215SLCCG1AZZ01A
Brand Manufacturer General Electric (GE)
Control System Line Speedtronic Mark V / Drive Excitation Systems
Module Classification Local Area Network (LAN) Communications Card
Functional Acronym SLCC Assembly Group
Core Process Node Dedicated U1 LAN Control Processor (LCP)
Embedded Data Protocols Distributed Local Area Network (DLAN) and ARCNET
Firmware Storage Architecture Dual Replaceable EPROMs (Positions U6 and U7)
PCB Protective Shell Standard Conformal Coating Class G1
Physical Dimensions 18 cm L x 13 cm W x 3 cm H
Hardware Shipping Weight 0.65 kg (1 lb, 7 oz)
Environmental Operating Window 0 to 50 deg C Ambient Temperature
Manufacturing Origin United States (USA)

System Integration & Diagnostics FAQs

What specific field function does jumper JP19 perform on the DS215SLCCG1AZZ01A circuit board?

Jumper JP19 serves as the physical hardware routing link that bridges the onboard timing crystal oscillator directly to the primary LAN Control Processor. Modifying this jumper during standard maintenance alters the microprocessor clock synchronization and will immediately disable network communications.

How can field teams update the baseline operating system files hosted on an active SLCC card?

The core processing software rules are embedded into physical, socketed EPROM chips positioned at U6 and U7. Updating firmware parameters or replacing corrupted operating system partitions requires substituting these physical microchips with factory-programmed units rather than running digital flash download utilities over the communication bus.

What is the significance of the dual isolated and non-isolated circuits integrated onto the board?

The card mixes isolated circuits for external DLAN and ARCNET line drops with non-isolated logic circuits for close-coupled communication with the main drive control module. The isolated paths use galvanic protection components to ensure that external lightning strikes, high-voltage shorts, or electrical field transitions along the network highway cannot pass into the core drive computer bus.


Engineering & Installation Guide

  • Electrostatic Discharge Mitigation Guidelines:

    The DS215SLCCG1AZZ01A contains high-density CMOS processors and volatile register paths highly vulnerable to static electricity. Keep the replacement card sealed inside its protective conductive bag until immediately before insertion. Technicians must connect a grounded static control wrist strap to the unpainted steel structural rail of the enclosure panel before handling the board, and grip the module strictly by its structural fiberglass outer edge to avoid skin contact with surface solder tracks.

  • Hardware Jumper Preservation and Customization Boundaries:

    The module incorporates manual JP Berg-type block links along with factory wire jumpers (WJ) clustered primarily along the lower left quadrant of the PCB substrate. The vast majority of these customizable components are hard-set or permanently tuned at the factory. Do not shift, bypass, or relocate any manual jumper pins from their baseline documentation positions, as incorrect configurations will corrupt system diagnostics, trigger hardware configuration mismatches, or cause system initialization failure.

  • Interconnect Cable Alignment and Retention:

    When connecting ribbon lines across ports 2PL, 3PL, 10PL, ARCPL, and KPPL, inspect the connector hoods for bent pins before engagement. Align the keys correctly to avoid reverse pin matching. Ensure that the integrated plastic locking ears click fully into place. Loose ribbon cable sockets under continuous machine deck vibrations create high contact resistance, causing intermittent signal degradation and network packet dropouts.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...