  • Manufacturer: Honeywell

  • Product No.: 51201748-210

  • Country of origin:United States

  • Product Type: Resistor Load Kit

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 14.0 x 14.0 x 7.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 51201748-210 is a specialized resistor load kit engineered for integration within Honeywell industrial automation and distributed control systems. This hardware component provides precise electrical loading characteristics required for specific peripheral power supply circuits and signal conditioning loops within cabinet assemblies.

Designed to mount within standard industrial control enclosures, the 51201748-210 maintains stability under continuous electrical operational loads. Its physical architecture supports secure termination wiring, ensuring uninterrupted circuit continuity in process control environments.

Features

  • Engineered specifically for Honeywell distributed control system peripheral power architectures
  • Provides stable resistive loading for circuit testing and signal balancing
  • Compact footprint designed for high-density cabinet layouts
  • Heavy-duty terminal connections for secure wire termination

Applications

  • Peripheral power supply load balancing in Honeywell DCS cabinets
  • Test and calibration procedures for industrial control power distribution
  • Signal conditioning circuit termination
  • Legacy system hardware maintenance and replacement

Technical Specifications

Parameter Specification
Brand Honeywell
Model / Part Number 51201748-210
Product Type Resistor Load Kit
System Compatibility Honeywell DCS Infrastructure
Net Weight 0.4 kg
Dimensions 14.0 x 14.0 x 7.0 cm
Country of Origin United States

FAQ

What is the primary function of the Honeywell 51201748-210?

The Honeywell 51201748-210 is a resistor load kit utilized within industrial control system enclosures to provide specific electrical loading for power supply or signal circuits.

What system architecture is the 51201748-210 designed for?

It is designed for integration within Honeywell distributed control system (DCS) peripheral hardware architectures.

How is the 51201748-210 mounted in a control cabinet?

The module is designed for mechanical installation within standard industrial control enclosures utilizing secure terminal and mounting interfaces.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.