To manage safety-critical field actuators within Honeywell Safety Manager environments, the FC-SDOL-0424 serves as a ruggedized fail-safe digital output module. This industrial component features four monitored output channels designed to drive 24 Vdc loads such as solenoid valves, indicators, and interposing relays up to 1 A per channel. Built-in short-circuit protection and overload detection mechanisms ensure high system availability and safety integrity in demanding industrial process control topologies. Each channel is monitored for line monitoring capabilities, allowing the safety controller to track field-side wiring integrity in real time.

Features

  • Four independent, short-circuit proof solid-state source output channels operating at 24 Vdc.
  • High-integrity diagnostic functions including overload detection and off-state leakage monitoring.
  • Internal fail-safe architecture designed for high-availability Safety Instrumented Systems (SIS).
  • Compact physical footprint conforming to standard Eurocard dimensions (4 HP width, 3U height).
  • Integrated watchdog (WDG) input verification to align output states with controller commands.

Applications

  • Emergency Shutdown Systems (ESD) in petrochemical plants.
  • Fire and Gas (F&G) mitigation control and alarming networks.
  • Burner Management Systems (BMS) in industrial boilers and power generation facilities.
  • Critical process safety interlocks in water treatment and chemical refineries.

Technical Specifications

Manufacturer Honeywell
Part Number/Model FC-SDOL-0424
Module Type Digital Output Module (Fail-safe)
Number of Channels 4
Output Configuration 24 Vdc solid-state source (short-circuit proof)
Maximum Channel Current 1 A
Maximum Total Module Load 3.6 A (dissipation limit)
Maximum Load Inductance 0.5 H
Maximum Load Capacitance 1 uF
Overload Detection Threshold Greater than 10 Ohm
Cold Lamp Resistance Greater than 20 Ohm
Voltage Drop Less than 1.3 V at 1 A
Off-state Leakage Current Less than 0.1 mA
Current Sense Voltage Drop Less than 1 V at 1 A
Watchdog (WDG) Input Current 4 mA
Power Requirements (5 Vdc) 15 mA
Power Requirements (24 Vdc Internal) 50 mA
Power Requirements (24 Vdc External) 15 mA (without output load)
Space Requirements 4 TE, 3 HE (4 HP, 3U rack space)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Insert the module into an allocated slot within a compatible 3U Safety Manager rack, ensuring secure locking and alignment with backplane connectors.
  • Wiring: Field connection paths must use correctly rated wire gauges to handle continuous 1 A loads. Route low-voltage diagnostic lines separated from high-current AC power cables.
  • Cooling: Maintain clearance margins at the top and bottom of the subrack assembly to allow convective airflow, keeping operating temperatures within specifications.

Compliance and Certifications

  • CE
  • TUV (for safety instrumented functions up to SIL 3)
  • UL Listed
  • CSA Certified
  • FM Approved (Class I, Division 2 Hazardous Locations)
Loading product navigation…

What is the maximum output current capacity per channel for the FC-SDOL-0424?

Each of the 4 channels supports a maximum continuous current of 1 A, with a maximum module-wide load limit of 3.6 A due to thermal dissipation parameters.

Does the FC-SDOL-0424 digital output module support short-circuit protection?

Yes, the module is equipped with solid-state source outputs that are fully short-circuit proof and include overload detection thresholds.

Which safety systems is the FC-SDOL-0424 compatible with?

The module is designed for Honeywell Safety Manager systems and is certified by TUV for use in safety instrumented systems (SIS) up to SIL 3.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...