Description
Facilitating seamless serial communication within industrial process safety networks, the FS-DCOM-232/485 serves as a dedicated communication interface module developed by Honeywell. This module establishes a reliable bridge between control processors and peripheral systems, translating signal levels across standard serial interfaces to ensure secure, real-time data flow. Designed for integration within Honeywell safety-related control architectures, the module manages signal physical-layer conversion with high noise immunity and minimal latency.
The unit supports dual-protocol configurations, allowing operators to interface via either RS-232 or high-speed RS-485/422 networks. Power is drawn directly from the system control processor, eliminating the need for external power supplies and simplifying cabinet wiring. Its compact footprint and standardized DIN rail mounting design make it suitable for high-density cabinet layouts in critical infrastructure installations.
Features
- Dual interface compatibility supporting both EIA/TIA-232 and EIA/TIA-485-A physical layers.
- Direct backplane power configuration via the system's Control Processor.
- High-speed serial data transmission with support for multiple coding methods including transparent, FM0, FM1, and Manchester coding.
- Rugged, industrial-grade housing engineered for DIN rail installations.
- Galvanic isolation and signal conditioning for reliable performance in electrically noisy environments.
Applications
- Safety Instrumented Systems (SIS) and Fail-Safe Control (FSC) networks.
- Integration of safety PLCs with distributed control systems (DCS) and SCADA hosts.
- Industrial monitoring networks in oil and gas, petrochemical, and power generation sectors.
- Interface connections to remote terminal units (RTUs), flow computers, and gas chromatographs.
Technical Specifications
| Manufacturer |
Honeywell |
| Part Number / Model |
FS-DCOM-232/485 |
| Module Type |
Communication Interface Module |
| Input Voltage |
5 Vdc (+/-5%) |
| Input Current |
Max 500 mA (supplied by the Control Processor) |
| RS-232 Output Levels |
According to EIA/TIA-232 standards |
| RS-232 Baud Rate |
0 to 250 kBaud |
| RS-485/422 Output Levels |
According to EIA/TIA-485-A standards |
| RS-485/422 Baud Rate |
0 to 2 MBaud (supports transparent, FM0, FM1, or Manchester coding) |
| Mounting Options |
DIN EN rails: TS32 / TS35 x 7.5 |
| Required Rail Length |
117 mm (4.6 in) |
| Module Dimensions (L x W x H) |
110 x 70 x 61 mm |
| Terminal Dimensions (L x W x H) |
6 x 57 x 47 mm |
| Shipping Weight |
2.0 kg |
Installation Guidelines
When installing the module, mount the unit horizontally on a standard TS32 or TS35 x 7.5 DIN rail. Ensure a minimum of 117 mm of continuous rail length is allocated to accommodate the module and its terminal connections. To prevent thermal buildup, maintain adequate ventilation spacing of at least 20 mm above and below the module housing. All serial interface cables must be shielded, with the shield terminated to the local cabinet ground point to prevent electromagnetic interference.
Compliance and Certifications
- CE Mark
- TUV Rheinland Certified for Safety-Related Systems
- UL Listed
- FM Approved