Honeywell

Honeywell MU-TPIX12 51304084-100 Pulse Input FTA Module

SKU MU-TPIX12 51304084-100

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: MU-TPIX12 51304084-100
  • Product Type: Pulse Input Modules
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.72 kg
  • Dimensions: 30.7cm x 12cm x 6.8cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Honeywell MU-TPIX12 (model 51304084-100) is a high-reliability Pulse Input Field Termination Assembly (FTA) designed for use within Honeywell Experion PKS and related distributed control systems (DCS). This module serves as a critical interface between industrial field instrumentation—such as flow meters, tachometers, and pulse-generating sensors—and the system I/O cards, translating frequency and pulse signals into accurate control data.

Engineered for mission-critical industrial applications, the MU-TPIX12 facilitates efficient signal conditioning and routing. It minimizes electrical noise interference and ensures high-fidelity pulse train transmission. The assembly integrates directly into standard Honeywell cabinet architectures, providing dependable point-to-point connection security for continuous process monitoring and batch measurement applications.

Features

  • Designed specifically for pulse input and frequency measurement field signals
  • Provides secure termination and signal conditioning for high-accuracy meters
  • Compatible with standard Honeywell Experion PKS DCS system architectures
  • Robust industrial construction built to withstand demanding plant environments
  • Standardized connectivity utilizing reliable multi-pin interface cabling

Applications

  • Flow measurement and custody transfer monitoring
  • Turbine speed and rotational velocity acquisition
  • Batch processing and totalization loops
  • Oil and gas production facilities
  • Chemical and petrochemical refining plants

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model MU-TPIX12
Part Number 51304084-100
Product Type Pulse Input FTA (Field Termination Assembly)
System Family Experion PKS DCS / MU-T Series
Input Type Pulse / Frequency signals
Mounting DIN rail or panel mounting via standard Honeywell hardware
Country of Origin USA

Connections / Interfaces

Interface Function
Field Terminations Screw terminals for direct connection of field sensor signal wires
System Cable Connector Multi-pin D-sub connector linking the FTA to the I/O module

Installation Guidelines

  1. Verify the part number and ensure the exact model MU-TPIX12 51304084-100 matches your system design specifications.
  2. De-energize the associated cabinet power and I/O channels before handling wiring or hardware.
  3. Inspect the termination board and connectors for any transport damage or contamination.
  4. Mount the FTA securely to the designated panel or DIN rail within the control cabinet.
  5. Connect field sensor leads to the appropriate screw terminals following standard loop drawings.
  6. Attach the system pre-formed cable between the FTA D-sub connector and the corresponding I/O module.
  7. Restore power and verify signal scaling and pulse reception via the Experion DCS engineering station.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell MU-TPIX12 51304084-100?
The Honeywell MU-TPIX12 51304084-100 functions as a Pulse Input Field Termination Assembly (FTA), routing and conditioning frequency and pulse signals from field devices like flow meters into the DCS I/O infrastructure.
Which control systems are compatible with the MU-TPIX12 51304084-100?
The Honeywell MU-TPIX12 51304084-100 is designed specifically for integration within Honeywell Experion PKS and related distributed control systems utilizing the MU-T series architecture.
What type of signals does this FTA process?
The Honeywell MU-TPIX12 51304084-100 processes pulse and frequency signals typically generated by turbine flow meters, positive displacement meters, and rotational speed sensors.
How does the MU-TPIX12 connect to the control system I/O?
The Honeywell MU-TPIX12 51304084-100 connects field wiring via screw terminals and interfaces to the I/O card using a standard multi-pin system cable connector.
Reviews

MU-TPIX12 51304084-100

Stock & lead time on request

Call
1 of 3

Honeywell MU-TPIX12 51304084-100 Pulse Input FTA Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: MU-TPIX12 51304084-100

  • Product Type: Pulse Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 720g

  • Dimensions: 30.7cm x 12cm x 6.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Honeywell MU-TPIX12 (model 51304084-100) is a high-reliability Pulse Input Field Termination Assembly (FTA) designed for use within Honeywell Experion PKS and related distributed control systems (DCS). This module serves as a critical interface between industrial field instrumentation—such as flow meters, tachometers, and pulse-generating sensors—and the system I/O cards, translating frequency and pulse signals into accurate control data.

Engineered for mission-critical industrial applications, the MU-TPIX12 facilitates efficient signal conditioning and routing. It minimizes electrical noise interference and ensures high-fidelity pulse train transmission. The assembly integrates directly into standard Honeywell cabinet architectures, providing dependable point-to-point connection security for continuous process monitoring and batch measurement applications.

Features

  • Designed specifically for pulse input and frequency measurement field signals
  • Provides secure termination and signal conditioning for high-accuracy meters
  • Compatible with standard Honeywell Experion PKS DCS system architectures
  • Robust industrial construction built to withstand demanding plant environments
  • Standardized connectivity utilizing reliable multi-pin interface cabling

Applications

  • Flow measurement and custody transfer monitoring
  • Turbine speed and rotational velocity acquisition
  • Batch processing and totalization loops
  • Oil and gas production facilities
  • Chemical and petrochemical refining plants

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model MU-TPIX12
Part Number 51304084-100
Product Type Pulse Input FTA (Field Termination Assembly)
System Family Experion PKS DCS / MU-T Series
Input Type Pulse / Frequency signals
Mounting DIN rail or panel mounting via standard Honeywell hardware
Country of Origin USA

Connections / Interfaces

Interface Function
Field Terminations Screw terminals for direct connection of field sensor signal wires
System Cable Connector Multi-pin D-sub connector linking the FTA to the I/O module

Installation Guidelines

  1. Verify the part number and ensure the exact model MU-TPIX12 51304084-100 matches your system design specifications.
  2. De-energize the associated cabinet power and I/O channels before handling wiring or hardware.
  3. Inspect the termination board and connectors for any transport damage or contamination.
  4. Mount the FTA securely to the designated panel or DIN rail within the control cabinet.
  5. Connect field sensor leads to the appropriate screw terminals following standard loop drawings.
  6. Attach the system pre-formed cable between the FTA D-sub connector and the corresponding I/O module.
  7. Restore power and verify signal scaling and pulse reception via the Experion DCS engineering station.
Loading product navigation…

What is the primary function of the Honeywell MU-TPIX12 51304084-100?

The Honeywell MU-TPIX12 51304084-100 functions as a Pulse Input Field Termination Assembly (FTA), routing and conditioning frequency and pulse signals from field devices like flow meters into the DCS I/O infrastructure.

Which control systems are compatible with the MU-TPIX12 51304084-100?

The Honeywell MU-TPIX12 51304084-100 is designed specifically for integration within Honeywell Experion PKS and related distributed control systems utilizing the MU-T series architecture.

What type of signals does this FTA process?

The Honeywell MU-TPIX12 51304084-100 processes pulse and frequency signals typically generated by turbine flow meters, positive displacement meters, and rotational speed sensors.

How does the MU-TPIX12 connect to the control system I/O?

The Honeywell MU-TPIX12 51304084-100 connects field wiring via screw terminals and interfaces to the I/O card using a standard multi-pin system cable connector.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

No detailed specifications found for this SKU.

Technical knowledge

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.