Mitsubishi Electric

Mitsubishi Electric FX3GE-40MT/ES MELSEC FX3G Series Programmable Controller

SKU FX3GE-40MT/ES

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX3GE-40MT/ES

  • Country of origin:United States

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 800g

  • Dimensions: 175 mm x 90 mm x 86 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Managing complex industrial tasks with localized automation is streamlined using the Mitsubishi Electric FX3GE-40MT/ES programmable logic controller. This compact, all-in-one base unit integrates high-performance microprocessing with built-in digital inputs, transistor outputs, analog processing, and dual communication interfaces. Engineered as an extension of the reliable MELSEC FX3G architecture, this controller features embedded Ethernet and USB ports, eliminating the need for external expansion cards in space-constrained control panels.

Features

  • High-Speed Processing: Incorporates dual-layer architecture supporting standard program capacity up to 32,000 steps.
  • Built-In Ethernet: Standard RJ45 port supporting 10BASE-T/100BASE-TX for seamless SCADA, HMI, and network integration.
  • Integrated Analog I/O: Factory-configured with 2 channels of analog input and 1 channel of analog output.
  • Positioning Capabilities: High-speed counter inputs up to 60 kHz and positioning pulse outputs up to 100 kHz.
  • Flexible Expansion: Scalable layout utilizing FX3 series expansion boards and special function blocks.

Applications

  • Packaging and automated sealing systems.
  • Local water treatment plants and pumping stations.
  • Conveyor networks and automated materials handling.
  • HVAC monitoring and remote telemetry systems.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model / Article Number FX3GE-40MT/ES
Series MELSEC FX3GE
Rated Power Supply 100 to 240 V AC (+10% / -15%), 50/60 Hz
Total Integrated I/O Points 40 points
Digital Inputs 24 Inputs (24V DC, Sink/Source selected by terminal)
Digital Outputs 16 Outputs (Transistor, Sink)
Integrated Analog Inputs 2 Channels (0-10V DC / 4-20mA)
Integrated Analog Outputs 1 Channel (0-10V DC / 4-20mA)
Communication Ports Ethernet (RJ45), USB (Mini-B), RS-422
Memory Capacity 32,000 steps internal EEPROM program memory
Operating Temperature Range 0 to 55 degC (32 to 131 Fahrenheit)
Net Weight 0.8 kg
Dimensions (W x H x D) 175 mm x 90 mm x 86 mm

Connections and Interfaces

Terminal Label Function / Assignment
L / N 100-240 V AC Main Power Supply input
24V / 0V Auxiliary 24V DC sensor power output supply
S/S Sink/Source selector terminal for digital inputs
X000 - X027 24V DC Digital Inputs (high-speed counters on first channels)
Y000 - Y017 Transistor Sink Outputs (pulse output functionality on Y000-Y002)
V1+, I1+, VI1-, V2+, I2+, VI2- Analog Inputs (Channel 1 and Channel 2 voltage/current terminals)
V3+, I3+, VI3- Analog Output (Channel 3 voltage/current terminals)

Empirical Engineering Insights

Alternative Models & Compatibility

The FX3GE-40MT/ES offers a direct physical upgrade path for older FX1N-40MT-D and standard FX3G-40MT/ES micro-controllers. Existing FX3G ladder code is fully backward compatible. However, to access the built-in Ethernet parameters and configure analog channels directly without from/to instructions, software development must be completed in GX Works2 (version 1.98 or later).

Application Pitfalls & Engineering Notes

This controller features standard Transistor Sink outputs (indicated by the MT suffix). Connecting field loads wired as sink logic to an improper polarity source will destroy the internal optocouplers. Ensure that external auxiliary power supplies are properly bonded. Thermal dissipation issues can manifest inside sealed control cabinets if the unit is installed horizontally; strictly adhere to vertical wall-mount layouts allowing a minimum clearance of 50mm above and below the chassis for natural convection airflow.

Commissioning & Wiring Tips

To prevent electrical noise interference on the integrated analog channels, always separate the 0-10V / 4-20mA routing from high-current AC power cables. Run shielded twisted-pair (STP) wiring for analog loops and terminate the shield ground strictly at the PLC end to block localized ground loop currents from destabilizing sensor values.

Installation Guidelines

CRITICAL WARNING:

Isolate all main power sources prior to conducting installation, mounting, or termination work. Failure to de-energize external circuits can cause severe electrical shock, hardware failure, or unexpected movement of connected actuators.

1

Mount the controller onto a standard 35mm DIN rail or secure it to a flat backplate using integrated M4 mounting screw points.

2

Connect the main 100-240 V AC supply source to the terminal block, ensuring correct protective grounding (PE) alignment.

3

Wire input lines with the selected active polarity (Sink or Source orientation configured through the S/S terminal).

4

Connect program transmission via Ethernet or USB, launch GX Works2, and run diagnostic procedures to verify hardware registers.

FAQ

What is the out-of-the-box IP address for the FX3GE-40MT/ES?

This module does not ship with a default assigned IP address. To establish Ethernet communication, you must assign an IP, subnet, and default gateway parameters using GX Works2 software via a physical USB connection first.

Can the integrated analog inputs directly measure 4-20mA loops?

Yes, both onboard analog input channels can measure 4-20mA current signals. Configuration is performed in the system register parameters in GX Works2 alongside appropriate terminal-level connections.

Does the PLC require a back-up battery to retain memory over power losses?

No. The main programming sequence is saved directly to internal, non-volatile EEPROM memory. However, to preserve dynamic registers or system state relays, an optional FX3U-32BL battery can be fitted.

Can I expand this base controller with additional hardware blocks?

Yes, the controller supports direct connection to standard FX3U and FX3G expansion modules, adapter boards, and special function blocks to scale up input, output, or communication limits.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.