For high-density process data acquisition in industrial environments, the CJ1W-AD081-V1 serves as a reliable multi-channel analog input unit within the Sysmac CJ-series PLC platform. This module supports up to eight analog input channels on a single slot, making it highly efficient for cabinets with limited footprint. It interfaces directly with CJ1, CJ2, and compatible CPU racks via the system bus, facilitating rapid data transfers and streamlined diagnostic monitoring.
Each channel can be independently configured for different input signal types, allowing engineers to mix voltage and current signals on the same physical module. Key processing functions integrated directly into the hardware include scaling, peak hold, mean value processing, and input wire-disconnection detection, which reduces the computational load on the main CPU.
| Omron |
| CJ1W-AD081-V1 |
| CJ Series (CJ1, CJ2) |
| Analog Input Unit (Special I/O Unit) |
| 8 points |
| 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V |
| 4 to 20 mA |
| 1 MOhm minimum |
| 250 Ohm rated resistance |
| 1/4000 (standard mode), 1/8000 (high-resolution mode) |
| 250 microseconds/point max. |
| Voltage: +/-0.2% of F.S. | Current: +/-0.4% of F.S. |
| Photocoupler isolation between input terminals and PLC internal bus (no isolation between individual input channels) |
| 18-point terminal block (detachable) |
| 420 mA max. at 5 VDC (supplied via backplane) |
| 31 mm x 90 mm x 89 mm (W x H x D) |
| 150 g (excluding shipping packaging) |
| 0 to 55 degC |
The unit features an 18-point detachable terminal block. Users can pre-wire the block before attaching it to the module. Terminal mappings should follow standard instrumentation wiring layouts:
| Terminal Pair | Signal Designation | Description |
|---|---|---|
| A1 / B1 | V IN 1 / I IN 1 | Input 1 Voltage (+) / Input 1 Current (+) |
| A2 / B2 | COM 1 | Input 1 Common (-) |
| A3 / B3 | V IN 2 / I IN 2 | Input 2 Voltage (+) / Input 2 Current (+) |
| A4 / B4 | COM 2 | Input 2 Common (-) |
| A5 / B5 | V IN 3 / I IN 3 | Input 3 Voltage (+) / Input 3 Current (+) |
| A6 / B6 | COM 3 | Input 3 Common (-) |
| A7 / B7 | V IN 4 / I IN 4 | Input 4 Voltage (+) / Input 4 Current (+) |
| A8 / B8 | COM 4 | Input 4 Common (-) |
| A9 / B9 | NC / SLD | No Connection / Shield Ground Terminal |
Note: Terminals A10 through B18 follow a repeating functional layout for Inputs 5 through 8. When using current inputs, short-circuit the voltage input (V IN) and current input (I IN) terminals for that channel.
Global Express Shipping
Returns & Warranty

For high-density process data acquisition in industrial environments, the CJ1W-AD081-V1 serves as a reliable multi-channel analog input unit within the Sysmac CJ-series PLC platform. This module supports up to eight analog input channels on a single slot, making it highly efficient for cabinets with limited footprint. It interfaces directly with CJ1, CJ2, and compatible CPU racks via the system bus, facilitating rapid data transfers and streamlined diagnostic monitoring.
Each channel can be independently configured for different input signal types, allowing engineers to mix voltage and current signals on the same physical module. Key processing functions integrated directly into the hardware include scaling, peak hold, mean value processing, and input wire-disconnection detection, which reduces the computational load on the main CPU.
| Omron |
| CJ1W-AD081-V1 |
| CJ Series (CJ1, CJ2) |
| Analog Input Unit (Special I/O Unit) |
| 8 points |
| 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V |
| 4 to 20 mA |
| 1 MOhm minimum |
| 250 Ohm rated resistance |
| 1/4000 (standard mode), 1/8000 (high-resolution mode) |
| 250 microseconds/point max. |
| Voltage: +/-0.2% of F.S. | Current: +/-0.4% of F.S. |
| Photocoupler isolation between input terminals and PLC internal bus (no isolation between individual input channels) |
| 18-point terminal block (detachable) |
| 420 mA max. at 5 VDC (supplied via backplane) |
| 31 mm x 90 mm x 89 mm (W x H x D) |
| 150 g (excluding shipping packaging) |
| 0 to 55 degC |
The unit features an 18-point detachable terminal block. Users can pre-wire the block before attaching it to the module. Terminal mappings should follow standard instrumentation wiring layouts:
| Terminal Pair | Signal Designation | Description |
|---|---|---|
| A1 / B1 | V IN 1 / I IN 1 | Input 1 Voltage (+) / Input 1 Current (+) |
| A2 / B2 | COM 1 | Input 1 Common (-) |
| A3 / B3 | V IN 2 / I IN 2 | Input 2 Voltage (+) / Input 2 Current (+) |
| A4 / B4 | COM 2 | Input 2 Common (-) |
| A5 / B5 | V IN 3 / I IN 3 | Input 3 Voltage (+) / Input 3 Current (+) |
| A6 / B6 | COM 3 | Input 3 Common (-) |
| A7 / B7 | V IN 4 / I IN 4 | Input 4 Voltage (+) / Input 4 Current (+) |
| A8 / B8 | COM 4 | Input 4 Common (-) |
| A9 / B9 | NC / SLD | No Connection / Shield Ground Terminal |
Note: Terminals A10 through B18 follow a repeating functional layout for Inputs 5 through 8. When using current inputs, short-circuit the voltage input (V IN) and current input (I IN) terminals for that channel.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|