Omron

Omron NS5-SQ10B-EVV2 NS Series Interactive Display Panel

SKU NS5-SQ10B-EVV2

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron
  • Product No.: NS5-SQ10B-EVV2
  • Origin Japan
  • Product Type: HMI Touchscreens
  • Payment: T/T, Western Union
  • Weight: 1.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

Facilitating advanced machine-to-operator visualization, the Omron NS5-SQ10B-EVV2 terminal is an industrial human-machine interface designed for real-time monitoring and control in automated setups. Engineered to integrate seamlessly with Sysmac automation platforms, this unit provides a highly legible, resistive analog touch display for machine adjustments, alarm tracking, and data log processing. It operates on a standard 24 VDC power input, making it a reliable diagnostic and interface point for industrial control panels.

Features

  • High-contrast 5.7-inch TFT color LCD screen offering clear visibility under typical industrial lighting.
  • Integrated dual RS-232C serial ports for direct connection to PLCs, temperature controllers, and specialized drives.
  • Onboard Ethernet port supporting FINS/TCP communication for high-speed network diagnostics and data transfers.
  • Long-life internal backup battery preserving system memory, clock data, and alarm histories during power cycles.
  • Analog resistive touch technology allowing customized touch targets and precise screen inputs even when operators wear industrial gloves.
  • Robust front panel design rated at IP65F for protection against dust, water spray, and oil mist.

Applications

  • Automated packaging and material handling conveyor lines.
  • Automotive subsystem and assembly line control visualization.
  • Water treatment systems and local environmental processing panels.
  • OEM machine integration and standalone product manufacturing machines.

Technical Specifications

Parameter Value / Specification
Manufacturer Omron
Model Reference NS5-SQ10B-EVV2
Display Type TFT Color LCD
Screen Size 5.7 inches (diagonal)
Resolution 320 x 240 pixels (QVGA)
Input Voltage 24 VDC (acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 W maximum
Battery Backup Life 5 years typical (at 25 degC)
Ambient Operating Temperature 0 to 50 degC
Operating Humidity 35% to 85% RH (non-condensing)
Front Panel Protection IP65F oil-proof / dustproof (when panel-mounted correctly)
Unit Weight 1.0 kg
Shipping Weight (Calculated) 8.0 kg (including bulk packaging)

Connections and Interfaces

Port / Interface Functional Assignment / Purpose
Serial Port A RS-232C, D-Sub 9-pin female (Host Link or 1:N NT Link protocol)
Serial Port B RS-232C, D-Sub 9-pin female (Connection to host PLC, barcode reader, or temp controller)
Ethernet RJ-45 (10Base-T/100Base-TX) for remote programming, monitoring, and multi-PLC communication
USB Host Type A connector for local memory backup, logging, and project transfer via USB flash drives
USB Slave Type B connector dedicated to direct screen design uploads/downloads from CX-Designer

Empirical Engineering Insights

Alternative Models & Compatibility

The "EVV2" designation indicates an integrated Ethernet physical layer and updated system runtime version over standard legacy NS5-SQ10B-V2 units. When upgrading older hardware configurations, ensure that you adjust the target hardware model inside Omron CX-Designer to match the exact "EVV2" profile to prevent compile-time addressing mismatches and compilation failures.

Application Pitfalls & Engineering Notes

To prevent premature display aging and CCFL/LED backlight burnout, configure the automatic Screen Saver function in your project properties to dim or power down the display backlight after 10 to 15 minutes of user inactivity. Also, avoid installing the terminal directly adjacent to heat-dissipating dynamic braking resistors or high-current AC contactors to maintain operational temperatures below the 50 degC ceiling.

Commissioning & Wiring Tips

For highly localized electromagnetic environments, ground the terminal's functional ground (FG) pin to a dedicated grounding point. Sharing an FG circuit with high-inductive loads like solenoids or drive motors introduces common-mode electrical noise, which can result in intermittent touchscreen ghost presses or unexpected communication link timeouts on the RS-232C ports.

Installation Guidelines

CRITICAL WARNING: Completely isolate and de-energize all primary and secondary power sources to the machine or control enclosure before starting mechanical installation or removing wiring terminals. Failure to verify zero-voltage state can cause severe electrical shock, circuit damage, or trans-receiver failure on connected PLC communications lines.
1
Ensure the control panel cutout dimensions conform exactly to the physical sizing parameters required for the 5.7-inch enclosure to prevent flexing of the HMI chassis.
2
Position the mounting gasket smoothly inside the front bezel perimeter to secure a true IP65F environmental seal against oil and water ingress.
3
Insert the hardware panel-mounting brackets into their corresponding slots and tighten them evenly to the specified torque rating, preventing touch panel warping.
4
Attach the terminal's 24 VDC power supply lines, keeping the DC run physically isolated from high-voltage AC cables inside the wire trunking.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the key difference between the standard NS5-SQ10B-V2 and the NS5-SQ10B-EVV2?
The EVV2 model features a built-in Ethernet port directly on the rear of the device, enabling direct FINS/TCP communication without requiring an external serial-to-Ethernet interface board.
What software program is required to program this Omron display panel?
You must use Omron CX-Designer, which is typically bundled as part of the standard CX-One software utility package.
How do you resolve erratic touch responses or false touchscreen touches?
Verify that the HMI functional ground (FG) terminal is securely bonded to a low-impedance ground point. High electromagnetic interference (EMI) from adjacent AC contactors or drives can create capacitive interference on the touchscreen panel if not grounded correctly.
Reviews

NS5-SQ10B-EVV2

Stock & lead time on request

Call
1 of 1

Omron NS5-SQ10B-EVV2 NS Series Interactive Display Panel

Only 7 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NS5-SQ10B-EVV2

  • Country of origin:Japan

  • Product Type: HMI Touchscreens

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Facilitating advanced machine-to-operator visualization, the Omron NS5-SQ10B-EVV2 terminal is an industrial human-machine interface designed for real-time monitoring and control in automated setups. Engineered to integrate seamlessly with Sysmac automation platforms, this unit provides a highly legible, resistive analog touch display for machine adjustments, alarm tracking, and data log processing. It operates on a standard 24 VDC power input, making it a reliable diagnostic and interface point for industrial control panels.

Features

  • High-contrast 5.7-inch TFT color LCD screen offering clear visibility under typical industrial lighting.
  • Integrated dual RS-232C serial ports for direct connection to PLCs, temperature controllers, and specialized drives.
  • Onboard Ethernet port supporting FINS/TCP communication for high-speed network diagnostics and data transfers.
  • Long-life internal backup battery preserving system memory, clock data, and alarm histories during power cycles.
  • Analog resistive touch technology allowing customized touch targets and precise screen inputs even when operators wear industrial gloves.
  • Robust front panel design rated at IP65F for protection against dust, water spray, and oil mist.

Applications

  • Automated packaging and material handling conveyor lines.
  • Automotive subsystem and assembly line control visualization.
  • Water treatment systems and local environmental processing panels.
  • OEM machine integration and standalone product manufacturing machines.

Technical Specifications

Parameter Value / Specification
Manufacturer Omron
Model Reference NS5-SQ10B-EVV2
Display Type TFT Color LCD
Screen Size 5.7 inches (diagonal)
Resolution 320 x 240 pixels (QVGA)
Input Voltage 24 VDC (acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 W maximum
Battery Backup Life 5 years typical (at 25 degC)
Ambient Operating Temperature 0 to 50 degC
Operating Humidity 35% to 85% RH (non-condensing)
Front Panel Protection IP65F oil-proof / dustproof (when panel-mounted correctly)
Unit Weight 1.0 kg
Shipping Weight (Calculated) 8.0 kg (including bulk packaging)

Connections and Interfaces

Port / Interface Functional Assignment / Purpose
Serial Port A RS-232C, D-Sub 9-pin female (Host Link or 1:N NT Link protocol)
Serial Port B RS-232C, D-Sub 9-pin female (Connection to host PLC, barcode reader, or temp controller)
Ethernet RJ-45 (10Base-T/100Base-TX) for remote programming, monitoring, and multi-PLC communication
USB Host Type A connector for local memory backup, logging, and project transfer via USB flash drives
USB Slave Type B connector dedicated to direct screen design uploads/downloads from CX-Designer

Empirical Engineering Insights

Alternative Models & Compatibility

The "EVV2" designation indicates an integrated Ethernet physical layer and updated system runtime version over standard legacy NS5-SQ10B-V2 units. When upgrading older hardware configurations, ensure that you adjust the target hardware model inside Omron CX-Designer to match the exact "EVV2" profile to prevent compile-time addressing mismatches and compilation failures.

Application Pitfalls & Engineering Notes

To prevent premature display aging and CCFL/LED backlight burnout, configure the automatic Screen Saver function in your project properties to dim or power down the display backlight after 10 to 15 minutes of user inactivity. Also, avoid installing the terminal directly adjacent to heat-dissipating dynamic braking resistors or high-current AC contactors to maintain operational temperatures below the 50 degC ceiling.

Commissioning & Wiring Tips

For highly localized electromagnetic environments, ground the terminal's functional ground (FG) pin to a dedicated grounding point. Sharing an FG circuit with high-inductive loads like solenoids or drive motors introduces common-mode electrical noise, which can result in intermittent touchscreen ghost presses or unexpected communication link timeouts on the RS-232C ports.

Installation Guidelines

CRITICAL WARNING: Completely isolate and de-energize all primary and secondary power sources to the machine or control enclosure before starting mechanical installation or removing wiring terminals. Failure to verify zero-voltage state can cause severe electrical shock, circuit damage, or trans-receiver failure on connected PLC communications lines.
1
Ensure the control panel cutout dimensions conform exactly to the physical sizing parameters required for the 5.7-inch enclosure to prevent flexing of the HMI chassis.
2
Position the mounting gasket smoothly inside the front bezel perimeter to secure a true IP65F environmental seal against oil and water ingress.
3
Insert the hardware panel-mounting brackets into their corresponding slots and tighten them evenly to the specified torque rating, preventing touch panel warping.
4
Attach the terminal's 24 VDC power supply lines, keeping the DC run physically isolated from high-voltage AC cables inside the wire trunking.

What is the key difference between the standard NS5-SQ10B-V2 and the NS5-SQ10B-EVV2?

The EVV2 model features a built-in Ethernet port directly on the rear of the device, enabling direct FINS/TCP communication without requiring an external serial-to-Ethernet interface board.

What software program is required to program this Omron display panel?

You must use Omron CX-Designer, which is typically bundled as part of the standard CX-One software utility package.

How do you resolve erratic touch responses or false touchscreen touches?

Verify that the HMI functional ground (FG) terminal is securely bonded to a low-impedance ground point. High electromagnetic interference (EMI) from adjacent AC contactors or drives can create capacitive interference on the touchscreen panel if not grounded correctly.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...