Precision data acquisition in modern machine control requires reliable, high-speed interfaces like the Omron NX-AD2208. This high-performance analog input unit is designed for the Omron NX Series platform, offering two differential channels dedicated to standard 4 to 20 mA analog current loops. Utilizing a high-resolution conversion of 1/30,000 and an ultra-fast conversion time of 10 us per point, it ensures rapid signal processing for demanding real-time industrial applications. The unit features flexible timing with support for both synchronous I/O refreshing and Free-Run refreshing, adapting perfectly to different system architectures via EtherCAT couplers or direct CPU connection.

Features

  • Two differential analog input channels dedicated to 4 to 20 mA signals.
  • Ultra-fast signal processing with a conversion time of 10 us per point.
  • High-resolution performance at 1/30,000 for precise process measurements.
  • Supports switching between synchronous I/O refreshing and Free-Run refreshing.
  • Screwless clamping terminal block with 8 terminals simplifies field wiring and resists vibration.
  • Integrated TS status indicator for immediate diagnostics.
  • Galvanic isolation between the input channels and the NX bus using a power transformer and digital isolator.

Applications

  • Continuous process monitoring (flow, pressure, and level transmitters).
  • High-speed industrial closed-loop feedback systems.
  • Water treatment facilities and chemical dosage monitoring.
  • OEM machinery integration with Sysmac NJ/NX controller networks.

Technical Specifications

ManufacturerModel / Part NumberProduct TypeNumber of InputsInput RangeInput TypeResolutionConversion TimeInput Conversion RangeAbsolute Maximum RatingInput ImpedanceOverall Accuracy (at 25 degC)Overall Accuracy (0 to 55 degC)Refreshing MethodIsolation MethodInsulation ResistanceDielectric StrengthPower Consumption (CPU connected)Power Consumption (Coupler connected)I/O Power Supply MethodExternal TerminalsDimensions (W x H x D)Weight
Omron
NX-AD2208
Analog Input Unit (Current)
2 points
4 to 20 mA
Differential
1/30000
10 us/point
-5% to 105% (full scale)
+/-30 mA
250 Ohms
+/-0.1% (full scale)
+/-0.2% (full scale)
Switching synchronous I/O refreshing and Free-Run refreshing
Between input and NX bus: Power = Transformer, Signal = Digital isolator (no isolation between individual input channels)
20 M Ohm min. between isolated circuits (at 100 VDC)
510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)
1.25 W max.
0.90 W max.
No supply required through terminals
Screwless clamping terminal block (8 terminals)
12 mm x 100 mm x 71 mm
0.07 kg

Installation Guidelines

  • Mounting: Mount the unit directly onto a standard 35 mm DIN rail. Ensure the interlocking side-connector blocks securely lock into adjacent NX modules.
  • Wiring: Use solid wires or stranded wires with ferrules. Push directly into the screwless clamping terminal block without using tools. To release, use a small flat-blade screwdriver on the release button.
  • Shielding: Connect the shielded outer conductor of the analog input cables to a functional ground bar to reduce electro-magnetic noise.
  • Environmental Maintenance: Maintain proper panel ventilation to ensure the operating environment remains within 0 to 55 degC.

FAQ

What is the primary input type for the Omron NX-AD2208?

The NX-AD2208 is an analog input unit configured for 2 differential current input channels supporting 4 to 20 mA signals.

What are the resolution and conversion speed specs for this module?

It features a high resolution of 1/30,000 and a high-speed conversion rate of 10 us per point.

Does the NX-AD2208 require an external I/O power supply?

No, it does not require an external I/O power supply terminal, drawing its operating power directly from the NX bus.

What refreshing methods does this analog unit support?

It supports both switching synchronous I/O refreshing and Free-Run refreshing to match controller cycle configurations.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.