Foxboro

P0931RM Foxboro I/A Series Redundant System Termination Cable

SKU P0931RM

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Foxboro

  • Product No.: P0931RM

  • Country of origin:France

  • Product Type: Redundant System Termination Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 360g

  • Dimensions: 18cm x 18cm x 5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The P0931RM (P0931RM) is a high-integrity Type 1 Termination Cable specifically engineered for the Foxboro I/A Series FBM216b HART® Communication Redundant Input SubsystemThis cable provides the critical physical link between the FBM216b Redundant Adapter (P0924DT) and the Compression-type Termination Assembly (P0924JH)Designed for high-availability environments such as oil refineriespower utility plants, and chemical processing, the P0931RM ensures that individually isolated HART input signals are transmitted without loss or interferenceBy utilizing premium Polyurethane materials, this cable maintains system uptime in mission-critical loops where signal failure is not an option.

Technical Configuration

As a Type 1 system cable, the P0931RM is defined by its specific electrical properties and physical construction tailored for redundant HART signal processing:

  • Redundancy Architecture: The cable connects to the Redundant Adapter, which combines signals from two adjacent FBM216b modules (Master and Tracker) into a single 25-pin output to the field.

     

  • Physical Interface: It features a 37-pin D-subminiature connector at the FBM Baseplate end and a 25-pin D-subminiature connector at the Termination Assembly end.

     

  • Material Composition: Constructed with a Polyurethane outer jacket and semi-rigid PVC primary conductor insulation, providing superior durability against industrial wear.

     

  • Standardized Length: This specific model (P0931RM) is the designated part number for the 2.0 meter (6.6 feet) version within the Type 1 cable family.

Technical Specifications

Attribute Specification Details
Model

 

P0931RM


Brand

 

Foxboro (Invensys/Schneider Electric)


Cable Type

Type 1 Termination Cable


Length

2.0 m (6.6 ft)


Connector A

37-pin D-subminiature (Baseplate End)


Connector B

25-pin D-subminiature (TA End)


Jacket Material

Polyurethane (P/PVC)


Operating Temp

-20 to +80 deg C (-4 to +176 deg F)


Subsystem Use

FBM216b Redundant Input Interface


Technical FAQs

Can the P0931RM cable be used with non-redundant FBMs?No, the P0931RM is a Type 1 cable specifically validated for use with the FBM216b redundant adapter configuration. For non-redundant 100 Series or 200 Series modules, different cable types are required to match the pin-out of standard baseplates.

What is the difference between P0931RM and the LSZH version?The P0931RM uses Polyurethane (P/PVC) with a temperature limit of +80 deg CThe LSZH version (P0928AC) is "Low Smoke Zero Halogen," designed for safety-critical areas where toxic smoke must be avoided during a fire, and supports up to +105 deg C.

Does this cable support HART digital communication?Yes. The cable is designed to carry the 4 to 20 mA analog signal with the digital HART FSK signal superimposed, maintaining the integrity of bi-directional digital communications with field devices.


Engineering & Installation Guide

  • Strain Relief: When connecting the 37-pin D-sub end to the redundant adapter, ensure the mounting lugs are tightened to prevent vibration-induced signal intermittent.

  • Bending Radius: Maintain a minimum bending radius of at least 10 times the cable diameter. Avoid sharp 90-degree bends near the connectors to prevent internal conductor fatigue.

  • Routing: Although the Polyurethane jacket is rugged, keep the P0931RM separate from high-voltage AC power lines within the cabinet to minimize EMI (Electromagnetic Interference) on the 4-20mA HART loops.

Engineering Advantages

The P0931RM is part of a UL/UL-C listed and ATEX Zone 2 certified subsystemIts construction is suitable for Class G3 (Harsh) environments, providing 15-bit resolution accuracy for HART signals even in corrosive or high-humidity atmospheresThe use of standard D-sub connectors allows for rapid "Plug-and-Play" replacement, which is critical for maintaining the high availability of the FBM216b redundancy pair.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Technical knowledge

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.

Designing Current Shunt Measurements That Stay Accurate

A practical guide to current-shunt measurement covering resistor sizing, high-side and low-side placement, Kelvin sensing, error budgets, thermal effects, protection and commissioning tests.

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.