Schneider Electric

Schneider Altistart 01 ATS01N209LU Soft Starter

SKU ATS01N209LU

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: ATS01N209LU

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 530g

  • Dimensions: 15cm x 17,2cm x 5,5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ATS01N209LU is a compact Soft Starter from the Altistart 01 range, developed by Schneider Electric to provide controlled starting for three-phase asynchronous motors. This unit is rated for a nominal current of 9 A and is designed to operate within a 200–240 V power supply range. It is optimized for motors up to 1.5 kW, offering a simplified solution for reducing mechanical stress on drive systems during the start-up phase.

The ATS01N209LU functions by limiting the starting torque and current surges, which prevents the "jerk" effect often associated with direct-on-line motor starting. Its space-saving, low-profile design makes it an ideal choice for machinery where installation space is restricted, providing a reliable and cost-effective way to extend the service life of motors and connected mechanical components.

Features

  • Smooth starting control to reduce mechanical shock
  • Nominal current rating of 9 A
  • Compatible with 1.5 kW asynchronous motors
  • Wide operational voltage range (200–240 V)
  • Compact, low-profile design for tight installation spaces
  • Easy to integrate into existing industrial control circuits

Applications

  • Small conveyor belts
  • Fans and pumps
  • Packaging machinery
  • Automated gate or door systems
  • Small-scale material handling equipment

Technical Specifications

Category Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 01
Product Type Soft starters
Current Rating 9 A
Operational Voltage 200 - 240 V
Motor Power Rating 1.5 kW
Dimensions 15.00 x 17.20 x 5.50 cm
Weight 0.53 kg
Product Phase Active
Commodity Code 84798997

Installation Guidelines

  • Mounting: Ensure the soft starter is mounted vertically to maintain natural convection cooling through the unit.
  • Clearance: Maintain a minimum clearance of 50 mm above and below the device to prevent heat buildup.
  • Connections: Ensure all power and control terminals are securely tightened to the specified torque settings.
  • Wiring: Use appropriately sized cabling for a 9 A load; separate power cables from control/logic signals to prevent electromagnetic interference (EMI).
  • Environment: Install in a clean, dry location free from conductive dust, corrosive chemicals, or excessive vibrations.

FAQ

What is the primary purpose of the ATS01N209LU?

It is used to provide smooth acceleration for three-phase asynchronous motors, reducing mechanical stress and current surges during start-up.

What is the motor power range for this model?

This soft starter is designed for motors up to 1.5 kW.

What is the supply voltage for this unit?

The ATS01N209LU operates with a 200–240 V power supply.

Is this product still active?

Yes, the ATS01N209LU is currently in the active phase of its product lifecycle.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.