Schneider Electric

Schneider Electric Altistart 22 ATS22D75S6U Soft Starter

SKU ATS22D75S6U

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric
  • Product No.: ATS22D75S6U
  • Origin France
  • Product Type: Soft starters
  • Payment: T/T, Western Union
  • Weight: 8.53 kg
  • Dimensions: 31cm x 36cm x 23cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The ATS22D75S6U is a Schneider Altistart 22 Soft Starter engineered for the controlled starting and stopping of three-phase asynchronous motors. Designed to reduce mechanical stress and electrical surges during motor startup, this soft starter manages a nominal current of 75 A and operates across a wide voltage range of 208V to 600V. It provides power control for motors rated between 20 HP and 60 HP, depending on the application voltage. The ATS22D75S6U features integrated bypass contactors and comprehensive protection functions to safeguard motors and machinery from overload, phase failure, and phase imbalance.

Features

  • Nominal current rating: 75 A
  • Wide operating voltage: 208V to 600V AC
  • Power compatibility: 20 HP to 60 HP
  • Integrated bypass contactor to reduce heat dissipation
  • Comprehensive motor protection features (overload, phase imbalance)
  • Compact design optimized for space-saving panel installation

Applications

  • Centrifugal and axial pumps
  • Ventilation and exhaust fans
  • Compressors
  • Conveyor systems
  • Industrial mixers and agitators

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 22
Product Type Soft Starter
Nominal Current 75 A
Voltage Range 208 - 600V AC
Power Rating 20 - 60 HP
Dimensions 31.00 x 36.00 x 23.00 cm
Weight 8.53 kg
Commodity Code 84798997
Export Control (ECCN) N

Installation Guidelines

  • Mounting: Install the soft starter in a vertical orientation within an enclosure that provides adequate ventilation. Ensure sufficient clearance is maintained above and below the unit to allow for convective cooling.
  • Environmental: Ensure the installation environment is free from dust, moisture, and corrosive gases. Use an enclosure with the appropriate IP rating for the specific application environment.
  • Wiring: Connect the line supply (L1, L2, L3) and motor terminals (T1, T2, T3) using appropriately sized power conductors as specified in the local electrical code.
  • Grounding: Secure a solid connection to the cabinet's main protective earth (PE) bus to ensure electrical safety and effective noise mitigation.
  • Configuration: Utilize the integrated keypad or communication interface to set starting parameters (torque ramp and voltage limit) tailored to the specific load characteristics of the motor.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the function of an Altistart 22 soft starter?
It provides a controlled voltage ramp during motor startup and shutdown to reduce mechanical wear and limit electrical current spikes.
What motors can be controlled by the ATS22D75S6U?
It is designed for three-phase asynchronous motors within the range of 20 HP to 60 HP, depending on the line voltage.
Does this unit require an external bypass contactor?
No, the Altistart 22 features an integrated internal bypass contactor to reduce heat and improve system efficiency.
Reviews

ATS22D75S6U

Stock & lead time on request

Call
1 of 1

Schneider Electric Altistart 22 ATS22D75S6U Soft Starter

Only 6 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS22D75S6U

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 8530g

  • Dimensions: 31cm x 36cm x 23cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATS22D75S6U is a Schneider Altistart 22 Soft Starter engineered for the controlled starting and stopping of three-phase asynchronous motors. Designed to reduce mechanical stress and electrical surges during motor startup, this soft starter manages a nominal current of 75 A and operates across a wide voltage range of 208V to 600V. It provides power control for motors rated between 20 HP and 60 HP, depending on the application voltage. The ATS22D75S6U features integrated bypass contactors and comprehensive protection functions to safeguard motors and machinery from overload, phase failure, and phase imbalance.

Features

  • Nominal current rating: 75 A
  • Wide operating voltage: 208V to 600V AC
  • Power compatibility: 20 HP to 60 HP
  • Integrated bypass contactor to reduce heat dissipation
  • Comprehensive motor protection features (overload, phase imbalance)
  • Compact design optimized for space-saving panel installation

Applications

  • Centrifugal and axial pumps
  • Ventilation and exhaust fans
  • Compressors
  • Conveyor systems
  • Industrial mixers and agitators

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 22
Product Type Soft Starter
Nominal Current 75 A
Voltage Range 208 - 600V AC
Power Rating 20 - 60 HP
Dimensions 31.00 x 36.00 x 23.00 cm
Weight 8.53 kg
Commodity Code 84798997
Export Control (ECCN) N

Installation Guidelines

  • Mounting: Install the soft starter in a vertical orientation within an enclosure that provides adequate ventilation. Ensure sufficient clearance is maintained above and below the unit to allow for convective cooling.
  • Environmental: Ensure the installation environment is free from dust, moisture, and corrosive gases. Use an enclosure with the appropriate IP rating for the specific application environment.
  • Wiring: Connect the line supply (L1, L2, L3) and motor terminals (T1, T2, T3) using appropriately sized power conductors as specified in the local electrical code.
  • Grounding: Secure a solid connection to the cabinet's main protective earth (PE) bus to ensure electrical safety and effective noise mitigation.
  • Configuration: Utilize the integrated keypad or communication interface to set starting parameters (torque ramp and voltage limit) tailored to the specific load characteristics of the motor.
Key Features:

What is the function of an Altistart 22 soft starter?

It provides a controlled voltage ramp during motor startup and shutdown to reduce mechanical wear and limit electrical current spikes.

What motors can be controlled by the ATS22D75S6U?

It is designed for three-phase asynchronous motors within the range of 20 HP to 60 HP, depending on the line voltage.

Does this unit require an external bypass contactor?

No, the Altistart 22 features an integrated internal bypass contactor to reduce heat and improve system efficiency.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...