Siemens

Siemens 3RW4056-6BB44 SIRIUS Soft Starter

SKU 3RW4056-6BB44

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 3RW4056-6BB44

  • Country of origin:Germany

  • Product Type: Soft starters

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 6770g

  • Dimensions: 33.20cm x 25.20cm x 17.20cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 3RW4056-6BB44 is a SIRIUS electronic soft starter designed to facilitate the smooth starting and stopping of three-phase induction motors. By providing a controlled voltage ramp, this unit reduces mechanical stress on the drive train and limits high inrush currents during startup, thereby extending the lifespan of motors, belts, and gearboxes. Rated for 162 A and 90 kW at 400 V, this device is intended for industrial applications where motor protection and controlled acceleration are critical. Please note that this product has been phased out, and the recommended functional successor is the SIRIUS 3RW5056-6AB14.

Features

  • Motor Control: Provides soft start and soft stop to minimize mechanical shock.
  • Capacity: Rated operational current of 162 A; 90 kW at 400 V.
  • Operational Voltage: 200–460 V AC.
  • Control Voltage: 230 V AC.
  • Connections: Rugged screw terminals for secure electrical termination.
  • Successor: Compatible with the SIRIUS 3RW5 series (Type: 3RW5056-6AB14).

Applications

  • Conveyor systems and transport equipment.
  • Pumps and compressor control.
  • Industrial fans and blowers.
  • Centrifuges and agitators.
  • HVAC system motors.

Technical Specifications

Feature Specification
Manufacturer Siemens
Range SIRIUS
Model 3RW4056-6BB44
Operational Current 162 A
Power Rating 90 kW (at 400 V)
Operational Voltage 200–460 V AC
Control Voltage 230 V AC
Protection Rating IP00
Weight 6.77 kg
Dimensions 33.20 cm x 25.20 cm x 17.20 cm
Origin Siemens

Installation Guidelines

  • Mounting: Mount the soft starter vertically in a control cabinet with adequate space above and below for cooling airflow.
  • Ventilation: Ensure the ambient temperature does not exceed 40 degC; provide forced ventilation if the enclosure heat dissipation is insufficient.
  • Wiring: Use appropriately sized power cables for 162 A operation. Tighten all screw terminals to the torque specifications provided in the original manual to prevent overheating.
  • Protection: The device is rated IP00; ensure it is installed within a properly rated electrical enclosure to provide protection against touch and environmental ingress.
  • Grounding: Connect the device chassis to a common protective earth (PE) busbar to ensure electromagnetic compatibility and operator safety.

FAQ

What is the recommended replacement for the 3RW4056-6BB44?

The preferred successor type for this phased-out soft starter is the SIRIUS 3RW5056-6AB14.

What are the primary operational parameters for this model?

It is rated for 162 A operational current and 90 kW power at 400 V, operating within a 200–460 V AC voltage range.

What is the ingress protection rating of this unit?

The device has an IP00 protection rating, meaning it requires installation inside a protective electrical cabinet.

How does the soft starter benefit motor operation?

It provides soft acceleration and deceleration, which reduces mechanical stress on the motor and connected equipment while minimizing inrush current.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany
Power source
AC-powered

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.