Description

The Woodward 8200-1300 is a digital governor from the 505 turbine control series designed for steam turbine applications. The unit provides digital control for single or dual split range actuator steam turbines, functioning either as a standalone unit or integrated within a plant's distributed control system (DCS).

The 8200-1300 features five internal PID controllers, including a speed/load PID controller, a cascade PID controller, and AUX1 and AUX2 PID controllers. An integrated operator control panel includes an 8.4-inch graphical control panel display and a 34-key keypad equipped with an emergency stop button, control navigation buttons, and four diagnostic status LEDs (CPU health, IO Lock, Summary Alarm, and Summary Trip). Internally, the unit utilizes a watchdog timer and a CPU fault circuit to continuously monitor microprocessor and memory health.

Features

  • Designed for single or dual split range actuator steam turbine control.
  • Configurable as a standalone unit or integrated into a plant DCS.
  • Integrated operator control panel with an 8.4-inch graphical display and 34-key keypad.
  • Front panel emergency stop button, navigation keys, and 4 diagnostic status LEDs.
  • Five internal PID controllers (speed/load, cascade, AUX1, AUX2, and auxiliary).
  • Internal watchdog timer and CPU fault circuit for continuous hardware and memory health monitoring.

Applications

  • Steam turbine digital governing and control
  • Single split range actuator steam turbines
  • Dual split range actuator steam turbines
  • Standalone turbine speed/load control
  • Distributed Control System (DCS) integrated turbine control

Technical Specifications

Parameter Specification
Manufacturer Woodward
Model 8200-1300
Product Series 505 Turbine Control Series
Input Voltage LVDC (18-32 Vdc)
Screen Size 8.4 inches
Keypad 34 Keys
Operating Temperature -30 degC to +70 degC (with display)
Storage Temperature -30 degC to +70 degC (recommended 0 degC to 40 degC)
Ingress Protection IP20
Pollution Degree Pollution Degree 2
Overvoltage Category Overvoltage Category 3
Hazardous Location Rating Class I, Div. 2, Groups A/B/C/D
Non-Hazardous Location Rating Suitable for non-hazardous locations
Field Wiring Requirement Stranded copper rated at least 75 degC

Installation Guidelines

  • Mount the unit securely within a suitable enclosure providing appropriate protection for the operating environment.
  • Use stranded copper field wiring rated for at least 75 degC for all electrical connections.
  • Connect the primary power source ensuring supply voltage stays within the specified LVDC (18-32 Vdc) limits.
  • Maintain proper clear space inside the cabinet to prevent heat buildup and adhere to the ambient operating temperature limit of -30 degC to +70 degC.

Compliance and Certifications

  • Hazardous Locations: Class I, Div. 2, Groups A, B, C, D
  • Ingress Protection: IP20
  • Safety & Environmental Standards: Pollution Degree 2, Overvoltage Category 3

FAQ

What power supply voltage does the device require?

The device operates on an LVDC power supply rated between 18 Vdc and 32 Vdc.

What type of steam turbine setups can the unit control?

The unit is designed to control steam turbines equipped with single or dual split range actuators.

What is the recommended operating temperature range?

The operating temperature range for the device with display is from -30 degC to +70 degC.

What field wiring is required for installation?

Installation typically requires stranded copper field wiring rated for at least 75 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 2
Only 1 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...