1 de 3

Allen-Bradley 1797-IE8 FLEX Ex Intrinsically Safe Analog Input Module

Allen-Bradley 1797-IE8 FLEX Ex Intrinsically Safe Analog Input Module

Only 4 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1797-IE8

  • Country of origin:Estados Unidos

  • Product Type: Analog Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 46 mm x 94 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Description

The 1797-IE8 is an intrinsically safe high-density analog input module designed for direct deployment within hazardous environments as part of the FLEX Ex distributed architecture. This component processes standard instrumentation signals from up to eight field transmitters, converting current waveforms into digitized data registers across an isolated internal backplane interface. By maintaining low-energy electrical circuits, the device isolates field-side power configurations from triggering combustion in atmospheres containing flammable gases, vapors, or dust.

This module houses eight non-isolated analog input channels configured to interface with two-wire or four-wire transmitters over a 4 to 20 mA signaling range. The 1797-IE8 mounts securely onto a dedicated FLEX Ex terminal base, enabling digital communication with host programmable logic controllers via specialized intrinsically safe network adapters supporting ControlNet Ex protocol configurations. It is commonly implemented in petrochemical processing, off-shore drilling, refinery complexes, and specialty chemical synthesis plants requiring strict explosion-proof engineering compliance.

Features

  • Eight discrete analog channels engineered for intrinsically safe field connections.
  • Direct processing of industrial standard 4 to 20 mA current loops.
  • Modular plug-in design for efficient terminal base integration and maintenance.
  • Internal galvanic isolation barriers separating field-side instrumentation from control infrastructure.
  • Integrated diagnostic capability to identify open-circuit or short-circuit signal faults.

Applications

  • Petroleum refinery distillation column pressure tracking.
  • Offshore oil platform combustible gas monitoring systems.
  • Chemical storage tank continuous level measurement.
  • Pharmaceutical solvent batching process temperature control loops.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX Ex
Part Number 1797-IE8
Module Type Intrinsically Safe Analog Input Module
Number of Inputs 8 Channels, Non-isolated
Signal Range 4 to 20 mA
Resolution 16 bits
Input Impedance 200 ohms
Isolation Voltage Galvanic isolation between field side and FlexBus
Power Consumption 6.5 W maximum
Intrinsically Safe Output Type Current-limited source parameters
Operating Temperature -20 to 60 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5% to 95% non-condensing
Country of Origin USA
Approximate Weight 0.20 kg
Approximate Dimensions 46 mm x 94 mm x 91 mm

Connections/Interfaces

Terminal Base Pin (Typical 1797-TB3) Function
Input 0 (+) to Input 7 (+) Analog Input Current Signal Connections
Return 0 (-) to Return 7 (-) Signal Common Return Paths
+V Ex Intrinsically Safe Transmitters Power Feed

Installation Guidelines

Hazardous Area Precautions

Verify all installation procedures comply with local national electrical codes for hazardous locations. Ensure the module is mated exclusively with an approved intrinsically safe FLEX Ex terminal base to maintain appropriate energy-limiting protective parameters.

DIN Rail Installation

Hook the top of the module chassis into the upper channel slot of the standard 35 mm DIN rail. Rotate the body downward with consistent force until the low-side locking tabs engage with the metallic track lip.

Shielding and Grounding

Terminate all instrumentation cable shields at the dedicated chassis ground bar provided on the terminal base assembly. Do not ground the cable shield at both ends of the run to prevent creating a ground loop inside the hazardous zone.

Thermal Management

Allow a minimum of 50 mm clearance on all sides of the terminal stack to facilitate natural air circulation. Confirm that the enclosure ventilation keeps ambient temperatures near the module body below 60 degC during maximum load conditions.

FAQ

What is the core function of this hardware components?

It provides an interface to receive and digitize analog signals from field transmitters located in explosive atmospheres while preventing ignition energies.

Does this module require an external zener barrier?

No, the module features built-in galvanic isolation and energy-limiting circuits designed to operate directly with field devices in hazardous zones.

Can this device measure voltage inputs like 0 to 10V?

No, this specific model is engineered exclusively to accept and process standard 4 to 20 mA current loop signals.

What terminal base is compatible with this unit?

It is designed to plug directly into the 1797-TB3 or 1797-TB3S intrinsically safe terminal base units.

Can this unit be swapped out while the network adapter is active?

Yes, it supports removing and replacing modules under power within hazardous areas when used with appropriate FLEX Ex terminal structures.

How does the controller detect an unplugged sensor wire?

The module registers an under-range fault parameter when the input current drops significantly below the standard 4 mA threshold.

Are the eight input channels electrically isolated from one another?

The eight channels share a common internal reference within the module, though the group is isolated from the main control backplane.

What communication protocol does the module use to talk to the PLC?

It sends data across the local backplane to a 1797 network adapter, which typically links to the main controller via a ControlNet Ex network.

Is calibration required before deploying the unit into service?

The hardware undergoes factory calibration before shipment, but electronic zero and span parameters can be adjusted via controller software.

What is the maximum operating temperature limit for this component?

The unit is specified to operate reliably in ambient industrial environments ranging up to 60 degC without active cooling.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Branco Acinzentado
Country of origin
Estados Unidos

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...