1 de 3

Módulo Lógico PanelView Plus 700 a 1500 Allen-Bradley 2711P-RP1X

Módulo Lógico PanelView Plus 700 a 1500 Allen-Bradley 2711P-RP1X

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: Allen-Bradley

  • Nº do Produto: 2711P-RP1X

  • País de origem:Estados Unidos

  • Tipo de Produto: Módulo Lógico

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 450g

  • Dimensões: 160 mm x 130 mm x 35 mm (H x W x D)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The 2711P-RP1X is a logic module family for Allen-Bradley PanelView Plus 700 to 1500 terminals. It attaches to the rear of the display module and provides the terminal processing, memory, communication, firmware, and operating-system functions.

The logic module includes 64 MB internal CompactFlash memory and 64 MB RAM. Its external connections include an Ethernet port, a serial port, two USB ports, and a CompactFlash card slot. Status indicators provide operating information for the installed terminal.

The official installation document uses 2711P-RP1x as the family designation. Individual module revisions are identified by their series suffix.

Features

  • Designed for PanelView Plus 700 to 1500 terminals
  • 64 MB internal CompactFlash memory
  • 64 MB RAM
  • Ethernet communication port
  • Serial communication port
  • Two USB ports
  • CompactFlash card slot
  • Integrated status indicators
  • Replaceable RAM module
  • Replaceable internal CompactFlash card
  • Rear-mounted connection to the display module
  • Field-installable module construction

Applications

  • PanelView Plus terminal logic-module replacement
  • Industrial machine operator interfaces
  • Manufacturing HMI stations
  • Production-line visualization terminals
  • Process equipment operator panels
  • Existing PanelView Plus system maintenance

Technical Specifications

General

Parameter Specification
Manufacturer Allen-Bradley
Model Family 2711P-RP1x
Product Type Logic Module
Product Series PanelView Plus
Compatible Terminal Range PanelView Plus 700 to 1500
Installation Location Rear of the display module

Memory

Parameter Specification
Internal CompactFlash 64 MB
RAM 64 MB
RAM Type SODIMM RAM
Firmware Storage Internal CompactFlash
Operating System Storage Internal CompactFlash

Module Series

Series Module Designation
Series A 2711P-RP1x/A
Series B 2711P-RP1x/B
Series C 2711P-RP1x/C
Series D 2711P-RP1x/D
Series E 2711P-RP1x/E
Series F 2711P-RP1xx/F
Series G 2711P-RP1xxx/G

Connections/Interfaces

Interface Function
Ethernet Port Ethernet network connection
Serial Port Serial communication connection
USB Ports Two USB device connections
CompactFlash Card Slot External CompactFlash card access
Internal CompactFlash Interface Firmware and operating-system storage
Display Module Connectors Connection between the logic module and display module
Status Indicators Module operating-status indication

Installation Guidelines

  • Disconnect all power from the terminal before installing or replacing the module.
  • Disconnect all power and communication cables before module removal.
  • Wear a properly grounded ESD wristband.
  • Work in a static-free environment.
  • Avoid touching exposed electronic components.
  • Install the RAM and internal CompactFlash before attaching the logic module when supplied separately.
  • Place the display module face-down on a clean, flat, stable surface.
  • Align the two logic-module connectors with the display-module connectors.
  • Press the logic module down until it is firmly seated.
  • Tighten the six captive screws to 0.58 N m (5 to 7 lb in).
  • Remove any attached communication module before replacing the logic module.
  • Reinstall the communication module after the logic module is securely mounted.
  • Verify the logic-module series before transferring RAM or internal CompactFlash components.
Loading product navigation…

Which terminals support the module?

The module family is designed for PanelView Plus 700 to 1500 terminals.

How much memory does the module include?

The module family includes 64 MB internal CompactFlash and 64 MB RAM.

Which communication interfaces are provided?

The module includes one Ethernet port, one serial port, and two USB ports.

Can the internal memory be replaced?

Yes. The RAM and internal CompactFlash can be installed or replaced separately.

What mounting torque is required?

Tighten the six captive screws to 0.58 N m, equivalent to 5 to 7 lb in.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Preto
Country of origin
Estados Unidos
Power source
Energia CC

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação, dentro da automação industrial. Ele mostra...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas em FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem às...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel fundamental na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...