Beckhoff C9900-E855 Control Panel Series Push-Button Extension

Beckhoff C9900-E855 Control Panel Series Push-Button Extension

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: C9900-E855

  • País de origem:Alemanha

  • Tipo de Produto: HMI Accessories & Extensions

  • Pagamento: T/T, Western Union

  • Peso: 500g

  • Dimensões: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Integrating physical control elements directly alongside industrial displays, the Beckhoff C9900-E855 push-button extension expands operator interface capabilities on CP6xxx and CP7xxx Control Panels and Panel PCs. Designed specifically for 15-inch display models without integrated keyboards, this robust hardware add-on mounts on the right-hand side of the display housing, streamlining manual operations and emergency stop interventions. The assembly is currently in its service phase, making it a critical spare part for maintaining legacy HMI systems.

Features

  • Ergonomic Layout: Designed for right-side mounting on 15-inch displays, providing natural auxiliary control accessibility.
  • Tactile Key Elements: Equipped with 16 square Siemens Signum push-buttons (30 x 30 mm) featuring integrated signal lamps for visual feedback.
  • Safety Integration: Features one high-visibility Siemens Signum emergency stop switch, directly wireable to dedicated safety relays.
  • Dual Connection Path: All primary push-button operations transmit digitally via CP-Link or USB using a normally-open (NO) contact, while secondary NO contacts are routed to an independent terminal row for hardware bypass.
  • Customizable Legend: Slotted design allows for quick installation of slide-in labels beneath push-button caps for individual key identification.

Applications

  • Automotive assembly lines and machining cells using Beckhoff CP6x12 or CP7x12 HMIs.
  • Process control workstations requiring a combination of touchscreen inputs and physical override switches.
  • Legacy machine retrofits where direct physical E-stop integration is mandatory.

Technical Specifications

Manufacturer Beckhoff Automation
Model / Article Number C9900-E855
Product Type Push-button Extension Module (Right Side)
HMI Compatibility CP6x12-00xx and CP7x12-00xx (15-inch display without keyboard)
Push-button Type 16 x Siemens Signum square keys (30 x 30 mm) with signal lamps
Emergency Stop 1 x Siemens Signum E-stop switch (directly wireable)
Interface Options CP-Link or USB (for primary NO contacts and signal lamps)
Secondary Wiring Terminal strip for direct hardwiring of secondary NO contacts
Current Lifecycle Status Service Phase
Shipping Weight (Calculated) 5.0 kg

Connections and Interfaces

Connection Path Function / Circuit Assignment
CP-Link / USB Interface Transmits visual lamp outputs and primary NO push-button state changes to the host controller.
Direct Terminal Row Allows direct point-to-point hardwiring of the secondary NO contacts for safety relays or external PLC input cards.
Emergency Stop Terminal Direct dry-contact terminal blocks for emergency loop integration. Does not route safety critical stops over USB.

Empirical Engineering Insights

Alternative Models & Compatibility

This unit is specifically dimensioned for legacy 15-inch housings without keyboards (CP6x12 and CP7x12). When upgrading or replacing older control hardware, verify the exact suffix code of your Control Panel; attempting to pair this module with 12-inch or 19-inch variants will cause physical layout mismatch and mounting failure.

Application Pitfalls & Engineering Notes

Note that the integrated signal lamps cannot be actuated via the secondary hardwired terminal strip. They operate exclusively via commands sent through the CP-Link or USB protocol. If the communication interface is interrupted, status feedback via the signal lamps will be lost, even if the primary dry contacts remain connected via hardwiring.

Commissioning & Wiring Tips

Always run the emergency stop circuit through the direct terminal row directly to an approved safety evaluation unit (such as Beckhoff TwinSAFE or an external Category 4 safety relay). Do not rely on CP-Link or USB communication paths for functional safety emergency stop commands.

Installation Guidelines

CRITICAL WARNING: Prior to mounting or wiring the push-button extension, ensure all power sources to the host Control Panel / Panel PC and auxiliary control loops are completely de-energized. Failure to isolate power may result in communication circuit damage or unexpected machine actuation.
  1. 1 Align the physical mounting brackets of the extension module with the right-hand chassis mounting points of the CP6xxx/CP7xxx housing.
  2. 2 Securely fasten the mounting screws to the specified torque limit to guarantee seal integrity and prevent vibration damage.
  3. 3 Connect the USB/CP-Link communications cable to the designated rear interface port on the Control Panel.
  4. 4 Route the safety circuit wiring directly from the emergency stop switch terminals to your safety controller, testing continuity before powering up the system.
Loading product navigation…

Can the signal lamps on the C9900-E855 be directly hardwired to a digital PLC output module?

No. The signal lamps inside the 16 Siemens Signum push-buttons receive their control and activation signals exclusively via the integrated CP-Link or USB communication interface.

How is the emergency stop button integrated into functional safety systems?

The Siemens Signum emergency stop switch features an independent contact block designed for direct wiring via the dry terminal strip, allowing standard integration into dual-channel safety relays.

Does this extension module support both CP-Link and USB communication simultaneously?

The module utilizes either CP-Link or USB depending on the interface of the parent Control Panel it is attached to, transmitting the primary key operations over the active bus.

Is the C9900-E855 compatible with all Beckhoff HMI screen sizes?

No. This extension is physically dimensioned and configured specifically for 15-inch vertical alignment on CP6x12 and CP7x12 Control Panels without physical keyboards.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...