1 de 1

Beckhoff EL6720 EtherCAT Terminal Lightbus Master

Beckhoff EL6720 EtherCAT Terminal Lightbus Master

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: EL6720

  • País de origem:Alemanha

  • Tipo de Produto: EtherCAT Terminals

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 24 mm x 100 mm x 52 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Directly integrating legacy Lightbus networks into high-speed EtherCAT architectures, the Beckhoff EL6720 serves as a deterministic 1-channel communication interface. Operating as a Lightbus master terminal, this unit facilitates high-speed optical fiber communications, ensuring complete immunity to electromagnetic interference in harsh electrical environments. The Beckhoff EL6720 provides an direct gateway between TwinCAT-based EtherCAT control systems and existing Lightbus field devices, handling up to 254 nodes with precise synchronization and minimal latency.

Features

  • High-Speed Communication: Sustained data transfer rates of 2.5 Mbaud over fiber-optic networks.
  • Broad Node Capacity: Supports connection of up to 254 fieldbus devices and a maximum of 65,280 I/O points.
  • Optical Noise Immunity: Dual-channel fiber-optic standard connectors minimize electrical noise propagation.
  • Deterministic Processing: Utilizes three priority-controlled logical communication channels for optimized task execution.
  • Real-Time Status Monitoring: Integrated diagnostic layout featuring 3 front-panel LEDs for instant hardware and network status verification.

Applications

  • Retrofitting and upgrading legacy Beckhoff Lightbus machinery to modern EtherCAT architectures.
  • Heavy industrial environments requiring high optical isolation from electromagnetic noise.
  • Distributed I/O networks spanning long distances inside high-voltage switchgear cabinets.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model / SKU EL6720
Technology Lightbus master terminal
Number of Fieldbus Channels 1
Data Transfer Rate 2.5 Mbaud
Interfaces 2 x fiber-optic standard connector Z1000 (plastic fiber) or Z1010 (HCS fiber)
Current Consumption E-bus Typically 240 mA
Hardware Diagnostics 3 LEDs
Housing Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Protection Rating / Position IP20 / Variable
Ex Marking II 3 G Ex nA IIC T4 Gc
Net Weight 70 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector Type Function Assignment
Tx Optical Port Fiber-optic Lightbus Transmitter Output (Z1000 / Z1010 connection)
Rx Optical Port Fiber-optic Lightbus Receiver Input (Z1000 / Z1010 connection)

Empirical Engineering Insights

Alternative Models & Compatibility

The EL6720 replaces legacy PCI master cards (such as the FC2001) by shifting the Lightbus controller functionality onto the standard DIN rail. TwinCAT 2.11 (or higher) and all versions of TwinCAT 3 fully support configuration of this module. Hardware topology requires a closed-ring configuration; ensure that there are no gaps in the optical line.

Application Pitfalls & Engineering Notes

Do not exceed a minimum bend radius of 25 mm for standard plastic optical fiber (POF) lines. Tight bends degrade light intensity, causing intermittent framing errors or complete "Ring Interrupted" diagnostic states. Always verify the quality of POF termination cuts; rough or jagged cuts degrade transmission signal margins dramatically.

Commissioning & Wiring Tips

During initial commissioning in TwinCAT System Manager, utilize the "Scan" function under the EtherCAT Master device. If the EL6720 is correctly initialized but cannot discover Lightbus devices downstream, verify that the Tx and Rx fibers have not been crossed at the terminal connector interface.

Installation Guidelines

CRITICAL WARNING: Completely de-energize the entire Bus Terminal assembly and ensure the system is locked out before snapping the module onto or removing it from the DIN rail. Hot-plugging or live insertion of EtherCAT terminals can degrade internal E-bus spring contacts and trigger fieldbus faults across the entire network node.
1 Align the EL6720 with the DIN rail guide and push firmly until the mounting latch clicks securely into place.
2 Slide adjacent terminals together, ensuring that the lateral tongue-and-groove joint is locked to guarantee continuous electrical contact of the internal E-bus.
3 Insert clean, perpendicular-cut Z1000 or Z1010 fiber cables into the designated optical ports until locked.
Loading product navigation…

What optical fiber connectors are compatible with the EL6720?

The terminal is compatible with Z1000 standard plastic fiber (POF) and Z1010 HCS (silica-clad) fiber optic connectors.

How much current does the EL6720 draw from the E-bus?

The module typically draws 240 mA from the internal E-bus. Ensure your power supply coupler or power feed terminal can cover this budget.

Does the EL6720 terminal support Distributed Clocks (DC)?

No, the EL6720 does not support Distributed Clocks. All timing sync is managed via the priority-controlled logical Lightbus master channels.

Can I replace an FC2001 Lightbus PCI card with the EL6720?

Yes. The EL6720 provides standard Lightbus master functionality over EtherCAT, allowing you to configure legacy Lightbus I/O nodes directly within TwinCAT without legacy PC cards.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...