1 de 3

Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer

Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer

Apenas 3 item(ns) restante(s) em estoque
  • Fabricante: Bently Nevada

  • Nº do Produto: 330880-28-15-035-00-02

  • País de origem:Estados Unidos

  • Tipo de Produto: PROXPAC XL Proximity Transducer

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 250g

  • Dimensões: 60 mm x 110 mm x 110 mm (H x W x D)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Option 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 15 (1.5 in standoff adapter) specify this PROXPAC XL Proximity Transducer configuration — 330880-28-15-035-00-02.

This integrated proximity transducer assembly combines the probe and Proximitor sensor into a single polyphenylene sulfide (PPS) housing. The self-contained design eliminates the need for an external extension cable between the probe and Proximitor sensor, as well as the need for a separate Proximitor junction enclosure. Field wiring connects directly between the monitors and the internal terminals. This configuration features a 3.5 in probe penetration depth (Option 035), no conduit fittings (Option 00), and a 3/4-14 NPT mounting thread (Option 02) suitable for severe industrial machinery case interfaces.

Features

  • Transducer probe with multiple hazardous area approvals (ATEX, IECEx, and CSA) for explosion-proof and intrinsically safe installations.
  • Integrated Proximitor sensor in the housing lid to eliminate external extension cables.
  • Conductive glass-fiber-reinforced polyphenylene sulfide (PPS) thermoplastic housing rated IP66 and Type 4X.
  • 1.5 in (38 mm) standoff adapter with a 3/4-14 NPT thread for rigid casing mounting.
  • 3.5 in (89 mm) stainless steel probe sleeve length for direct case penetration.
  • Supplied with two plugs and two washers under the no-fittings option.

Applications

  • Shaft vibration and axial position measurements on rotating machinery.
  • Direct integration on turbines, compressors, pumps, and industrial gearboxes.
  • Environments requiring IP66 or Type 4X protection against chemical exposure, moisture, and dust.
  • Hazardous industrial environments requiring intrinsically safe or non-incendive field wiring.

Ordering Information

Option / Segment Code on This SKU Description
Orderable Part Number 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer, English
A - Probe and Approvals Option 28 3300 XL 8 mm probe with Multiple Approvals
B - Standoff Adapter Option 15 1.5 in (38 mm) standoff length
C - Probe Penetration Option 035 3.5 in (89 mm) penetration length
D - Fittings Option 00 No fittings; two plugs and two washers
E - Mounting Thread Option 02 3/4-14 NPT mounting thread (required with standoff adapter)

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number 330880-28-15-035-00-02
System Component Integrated Proximity Transducer Assembly
Linear Range 2 mm (80 mils), from 0.25 mm to 2.3 mm (10 to 90 mils)
Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/- 5%
Input Voltage Requirement -17.5 Vdc to -26 Vdc (without barriers) at 12 mA max; -23 Vdc to -26 Vdc (with barriers)
Output Resistance 50 Ohm
Frequency Response 0 to 10 kHz (+0, -3 dB) with up to 305 m (1000 ft) of field wiring
Minimum Target Size 15.2 mm (0.6 in) diameter flat target
Shaft Diameter Limits Minimum 50.8 mm (2.0 in), Recommended 76.2 mm (3.0 in)
Housing Material UV-resistant, glass-reinforced conductive polyphenylene sulfide (PPS)
Probe Case and Sleeve Material AISI 304 stainless steel
Probe Tip Material Polyphenylene Sulfide (PPS)
Operating Temperature (Probe) -52 degC to +177 degC
Operating Temperature (Housing/Sensor) -52 degC to +100 degC
Storage Temperature Range -52 degC to +105 degC
Environmental Protection IP66 and Type 4X when properly sealed

Installation Guidelines

  • Torque the housing retaining nut to 29.5 N-m (260 in-lb).
  • Torque the probe sleeve locknut to 39.3 N-m (350 in-lb) to maintain the environmental pressure seal.
  • Verify that the internal grounding liner and retaining plate are clean and securely fastened.
  • Ensure field wiring terminals are protected by an enclosure of at least IP54.
  • Maintain a minimum separation of 40 mm (1.6 in) for axial installations or 38 mm (1.5 in) for radial configurations to avoid cross-talk.

Compliance and Certifications

ATEX/IECEx Ex ia IIC T4/T5 Ga, Ex ia IIIC T90C/T105C Dc (Intrinsically Safe); Ex nA IIC T4/T5 Gc, Ex ec IIC T4/T5 Gc (Non-sparking)
North American (cNRTLus) Class I, Zone 0: AEx/Ex ia IIC T4/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (Intrinsically Safe)
Non-Incendive Class I, Division 2, Groups A, B, C, D; Class I, Zone 2: AEx/Ex nA IIC T4/T5 Gc
CE Mark Complies with European directives
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330880-28-15-035-00-02 PROXPAC XL Proximity Transducer

What does the A: 28 option indicate for the 330880 assembly?

The A: 28 option indicates that this assembly is equipped with a 3300 XL 8 mm proximity probe and holds Multiple Approvals for hazardous locations, such as ATEX, IECEx, and CSA certifications.

Is an external extension cable required for this PROXPAC XL transducer?

No, the PROXPAC XL integrates both the probe and the Proximitor sensor inside a single thermoplastic housing lid. This design eliminates the need for an external extension cable and separate Proximitor junction box.

What is the penetration depth and mounting thread on this specific model?

The model features a probe penetration length (C option) of 3.5 inches (89 mm) and a 3/4-14 NPT mounting thread (E option), which is required because it includes a 1.5-inch standoff adapter.

What fittings are supplied under the D: 00 option?

The D: 00 option means the transducer assembly is supplied with no conduit fittings. Instead, it comes equipped with two plugs and two washers for custom or existing conduit entries.

What is the environmental rating of the housing?

The housing is constructed from glass-reinforced conductive polyphenylene sulfide (PPS) and is rated IP66 and Type 4X for protection in severe, corrosive, and wet industrial environments.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação, dentro da automação industrial. Ele mostra...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas em FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem às...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel fundamental na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...