Delta Electronics DVS-110W02-3SFP DVS-110 Series Managed Industrial Ethernet Switch

Delta Electronics DVS-110W02-3SFP DVS-110 Series Managed Industrial Ethernet Switch

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Delta Electronics

  • Nº do Produto: DVS-110W02-3SFP

  • País de origem:Estados Unidos

  • Tipo de Produto: Industrial Ethernet Switches

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Engineered for resilient deployment in rugged industrial environments, the Delta Electronics DVS-110W02-3SFP serves as a robust communications backbone featuring 7 Fast Ethernet ports and 3 Gigabit Ethernet combo ports. This managed switch optimizes critical industrial control loops by offering redundant dual-rate SFP slots alongside copper physical media, ensuring flexible fiber trunking across long distances. Encased in a rugged IP40 metal chassis, this device operates reliably across a wide temperature spectrum from -40 degC to 75 degC, matching the strict requirements of substation, wind power, and intelligent traffic management systems.

Key Features

  • Flexible Port Density: Incorporates 7 x 10/100Base-T(X) RJ45 copper ports and 3 x 10/100/1000Base-T / 100/1000Base-SFP combo ports.
  • Hardened Diagnostics: Dual digital inputs and dual relay outputs for immediate, on-site alarm notifications and system state integration.
  • Redundancy Mechanics: Supports redundant dual power inputs to preserve network status during primary source failures.
  • Industrial-Grade Enclosure: Heavy-duty IP40 metal housing provides superior heat dissipation and high electromagnetic immunity.
  • Advanced Management: Enables comprehensive ring redundancy, VLAN configuration, QoS priorities, and secure SNMP capabilities.

Applications

  • Substation automation and renewable energy SCADA collection nodes.
  • Traffic control cabinet systems requiring high operating temperature tolerances.
  • Water and wastewater plant networking utilizing distributed redundant PLC networks.
  • Factory floor automation with mixed copper-to-fiber industrial Ethernet networks.

Technical Specifications

Parameter Value
Manufacturer Delta Electronics
Model Number DVS-110W02-3SFP
Series DVS-110 Series
Copper RJ45 Ports 7 x 10/100Base-T(X), Auto MDI/MDI-X
Combo Ports 3 x 10/100/1000Base-T or 100/1000Base-SFP active dual-rate
Digital Inputs (DI) 2 x Dry Contact inputs (max state detection)
Digital Outputs (DO) 2 x Relay outputs (rated 1 A at 24 VDC)
Input Voltage Range Dual redundant 12 to 48 VDC terminal block inputs
Enclosure Protection IP40 metal case
Operating Temperature -40 degC to 75 degC
Storage Temperature -40 degC to 85 degC
Mounting Options DIN-rail mounting standard, optional wall mount
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal / Port Block Interface Assignment
Ports 1 to 7 10/100Base-T(X) RJ45 pins for local field devices
Ports 8 to 10 (Combo) Dual-purpose copper/fiber ports for Gigabit uplinks
Terminal Block (V1+, V1-) DC Primary Power Input (12 to 48 VDC)
Terminal Block (V2+, V2-) DC Backup/Redundant Power Input (12 to 48 VDC)
Terminal Block (DI1, DI2, DI COM) Digital Inputs for remote dry-contact sensor monitoring
Terminal Block (R1, R2) Relay contact outputs for automated trip/fault alerting

Empirical Engineering Insights

Alternative Models & Compatibility

The DVS-110W02-3SFP represents the premium high-availability model in the DVS-110 series. Unlike the non-SFP models (e.g., DVS-110W02), which rely solely on RJ45 copper uplinks, this variant supports mixed-mode topologies. If substituting for older series switches, ensure that the active SFP transceivers match the optical wavelength and distance limits of existing transceivers, as modern Delta firmware strictly monitors DDMI parameters and may report SFP diagnostic faults if mismatched or low-quality components are installed.

Application Pitfalls & Engineering Notes

While the DVS-110W02-3SFP switch functions perfectly up to 75 degC, operating near this limit inside unventilated, high-voltage control panels can accelerate the aging of internal electrolytic capacitors. To avoid localized thermal pockets, maintain at least 50 mm of vertical clearance above and below the switch chassis. Furthermore, standard-grade SFP transceivers can overheat and fail if run in environments exceeding 60 degC; always verify that installed transceivers are rated for extended industrial operating ranges.

Commissioning & Wiring Tips

To prevent operational ground loops, ground the switch's chassis directly to the field cabinet ground plate using a heavy gauge copper conductor connected to the protective earth screw on the switch's top block. Additionally, configure the SNMP alert thresholds within the switch's management utility during initial commissioning to capture dry-contact digital input changes, allowing immediate detection of physical cabinet door breaches or localized surge protection device (SPD) trips.

Installation Guidelines

CRITICAL WARNING

Verify that all incoming DC power lines are completely de-energized and locked out before wiring the terminal block connectors. Failure to isolate power can result in transient electric arcing, causing equipment damage or personal injury. Ensure the protective earth terminal is fully connected prior to completing any interface or power connection.

1
Mount the DVS-110W02-3SFP onto a standard 35 mm symmetric DIN rail, securing it with the rear-integrated spring-locked mounting bracket.
2
Connect the functional/protective earth terminal from the top of the switch body directly to the cabinet ground bar using a low-impedance copper wire.
3
Insert the stripped power conductors into the terminal block plug, secure the screw terminals, and plug the block into the switch (V1 and V2 for redundant topologies).
4
Insert necessary RJ45 copper cables and matching SFP transceivers, confirming positive click-locking for all physical media links.
Loading product navigation…

Does the DVS-110W02-3SFP support both single-mode and multi-mode SFP transceivers?

Yes. The three SFP slots support both single-mode and multi-mode SFP fiber transceivers operating at 100 Mbps or 1000 Mbps line speeds.

What happens if one of the dual DC power inputs fails?

The switch switches transparently to the secondary power input without packet loss, and can trigger the integrated alarm relay to warn operators of the power drop.

Can the digital inputs on this switch monitor dry contacts?

Yes, the two integrated digital inputs are designed for dry contact connection to easily integrate enclosure door switches or alarm sensors.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...