Mitsubishi Electric FR-E840-0230-4-60 FR-E800 Variable Frequency Drive

Mitsubishi Electric FR-E840-0230-4-60 FR-E800 Variable Frequency Drive

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: Mitsubishi Electric

  • Nº do Produto: FR-E840-0230-4-60

  • País de origem:Estados Unidos

  • Tipo de Produto: Variable Frequency Drives

  • Pagamento: T/T, Western Union

  • Peso: 4800g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed to deliver precise speed and torque control for three-phase induction and permanent magnet motors, the Mitsubishi Electric FR-E840-0230-4-60 is a high-performance 400V class variable frequency drive from the FR-E800 series. Featuring a conformal circuit board coating (designated by the -60 suffix), this unit is engineered for enhanced environmental resilience in atmospheres containing conductive dust, moisture, or corrosive gases. It operates with a Normal Duty (ND) rated current of 23.0 A and implements standard source logic (PNP) for its control and safety stop input circuits. The integrated voltage monitoring capability via terminal AM provides real-time operational feedback to supervisory control systems.

Key Features

  • Environmental Protection: Features a robust conformal coating on the internal circuit boards to prevent degradation from atmospheric contaminants.
  • Source Logic Interface: Configured for PNP (source) control input and safety stop signals, facilitating seamless integration with standard safety relays and controllers.
  • Voltage Monitoring: Equipped with an analog voltage output via terminal AM for simple, direct scaling of operational parameters.
  • Flexible Control Options: Supports advanced vector control and auto-tuning protocols for high torque performance at low speeds.

Applications

  • Conveyor and Material Handling Systems: Precise speed synchronization and acceleration profiling.
  • Pumping and Fan Infrastructure: Energy-efficient flow control with built-in PID functionalities.
  • Packaging and Food Processing Machinery: Reliable operation in washdown-adjacent panels thanks to coated PCBs.
  • Compressors and Centrifuges: High-starting torque execution for high-inertia physical loads.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Code FR-E840-0230-4-60
Series FR-E800
Voltage Class 400 V Class (Three-Phase Input)
Inverter ND Rated Current 23.0 A
Rated Frequency 50 Hz (Initial Setting)
Control Logic (Inputs) Source Logic (PNP)
Safety Stop Signal Logic Source Logic (Fixed)
Circuit Board Coating With Conformal Coating (Standard -60)
Plated Conductor Without Plated Conductors
Monitoring Specification Voltage (Terminal AM)
Device Net Weight 4.8 kg
Shipping Weight (Calculated) 7.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The "-60" suffix indicates that this drive is equipped with conformal PCB coating, making it physically interchangeable with standard uncoated FR-E840 models but highly preferred in corrosive or humid environments. Ensure that parameter configurations are cloned using FR Configurator2 software when swapping older FR-E700 series units, keeping in mind the structural differences in wiring terminals.

Application Pitfalls & Engineering Notes

When deploying this drive in dense control enclosures, keep the ambient air temperature under 50 degC. Surpassing this threshold requires appropriate current derating. If the drive is mounted side-by-side with zero clearance, the maximum operating temperature must be derated to 40 degC to avoid thermal overload faults.

Commissioning & Wiring Tips

This model is hard-configured for Source Logic (PNP) operation. When integrating with external controllers, ensure the common terminal connection matches the PNP routing path (typically terminal PC as 24VDC source). Use shielded twisted-pair cables for the AM voltage analog monitoring line to prevent inductive electrical noise from corrupting high-impedance feedback signals.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage levels remain present in the internal DC bus capacitors even after mains power is disconnected. Disconnect all primary power feeds and verify that the charge LED on the front face of the drive has fully extinguished. Wait a minimum of 10 minutes before touching terminals or physical connections to prevent severe electrical shock.
1
Mount the inverter vertically on a flat, non-flammable backplate, ensuring at least 50mm of clearance at the top and bottom to allow adequate cooling air circulation.
2
Connect the incoming 400V three-phase utility power lines exclusively to terminals L1, L2, and L3. Connection of main power lines to output terminals U, V, or W will destroy the drive.
3
Establish a solid low-impedance ground connection from the drive chassis to the main electrical system protective earth (PE) bus.
4
Ensure control wires are routed away from power cabling to eliminate electromagnetic cross-talk and maintain signal integrity.
Loading product navigation…

What does the -60 suffix in the FR-E840-0230-4-60 part number indicate?

The -60 suffix specifies that the printed circuit board has a conformal coating. This provides essential moisture, chemical, and dust protection for reliable operation in harsh industrial environments.

Can I configure this drive for Sink (NPN) control logic?

No, this specific model (FR-E840-0230-4-60) is hard-configured with Source (PNP) logic for its safety stop inputs and standard digital control terminals.

What is the rated current of this FR-E800 inverter under Normal Duty (ND)?

The unit features a Normal Duty rated output current of 23.0 A, indicated by the '0230' sequence in the model code.

What type of analog monitoring signal is provided by terminal AM?

Terminal AM is configured for analog voltage output monitoring, typically used for scaling speed, current, or voltage feedback to an external controller or meter.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...