1 de 1

Omron CJ1W-DA08C CJ Series 8-Channel Analog Output Module

Omron CJ1W-DA08C CJ Series 8-Channel Analog Output Module

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: CJ1W-DA08C

  • País de origem:Japão

  • Tipo de Produto: PLC Analog Output Modules

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 31 mm x 90 mm x 65 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Facilitating multi-channel analog current loop control within high-density industrial control panels, the Omron CJ1W-DA08C provides eight independent analog output channels directly integrated into the CJ-series PLC architecture. This unit converts 16-bit digital values into precise, proportional 4 to 20 mA current loop signals for driving field actuators, control valves, and drive references. Utilizing an 18-point detachable terminal block, it allows system integrators to perform field wiring offline or swap modules without disturbing existing field terminations. Designed as a Special I/O Unit, it features configurable output hold logic, built-in engineering scaling, and dedicated diagnostic status indicators to maximize process uptime.

Key Features

  • 8 High-Density Channels: Supports up to eight independent current loop outputs (4 to 20 mA) in a single-slot form factor.
  • Selectable Conversion Dynamics: Offers configurable resolution options of 4,000 or 8,000 steps with conversion times down to 250 us per point.
  • Advanced Output Hold Behaviors: Protects downstream machinery by outputting defined states (CLR, HOLD, or MAX) during PLC CPU stops, program changes, or error states.
  • Built-In Engineering Scaling: Allows direct conversion of user-defined units within a range of +/-32,000, eliminating the need for complex ladder logic calculations.
  • Photocoupler Isolation: Provides electrical separation between field-side connections and internal controller logic circuits.
  • Detachable M3 Terminal Block: Promotes rapid hardware replacement and minimizes system maintenance downtime.

Industrial Applications

  • Actuator Control: Direct modulation of proportional flow valves, dampers, and positioners in process control.
  • Motor Speed Regulation: Transmitting current reference speed commands to variable frequency drives (VFDs).
  • Data Recording Integration: Interfacing with legacy chart recorders, indicators, and external SCADA monitoring systems.
  • Environmental Control Systems: Providing analog setpoints to commercial HVAC control loops and multi-zone heating systems.

Technical Specifications

Parameter Specification Value
Manufacturer Omron Corporation
Model Number CJ1W-DA08C
Module Type CJ-Series Special I/O Unit
Number of Analog Outputs 8
Output Signal Range 4 to 20 mA
Maximum Permissible Load Resistance 350 Ohm
D/A Resolution Options 4,000 / 8,000 steps
Conversion Speed 1.0 ms or 250 us per active point
Output Accuracy at 25 degC +/-0.3% of Full Scale
Output Accuracy over Full Temp Range (0 to 55 degC) +/-0.6% of Full Scale
Internal Power Consumption 5 VDC at 140 mA maximum
External Power Supply Requirement 24 VDC (+10% / -15%), 170 mA maximum
Inrush Current Profile 20 A maximum, 1 ms minimum pulse width
Isolation Method Photocoupler (between I/O terminals and controller backplane logic; no isolation between individual output channels)
External Connections 18-point detachable terminal block with M3 terminal screws
Product Dimensions (W x H x D) 31 mm x 90 mm x 65 mm
Net Weight 150 g maximum
Shipping Weight (Calculated) 2.0 kg (with standard protective industrial packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The CJ1W-DA08C is fully form-factor compatible with all Omron CJ1G, CJ1H, and CJ2M/CJ2H CPU racks. When migrating legacy networks from the CJ1W-DA08V (voltage variant), please note that the CJ1W-DA08C is dedicated exclusively to current loop operations and cannot be modified via software configuration to supply voltage outputs. Always verify that your power supply module on the PLC rack has sufficient 5 VDC capacity to cover the 140 mA drawn by this unit along with any associated communication modules.

Application Pitfalls & Engineering Notes

A crucial architectural consideration when designing your panel layout is that there is no channel-to-channel isolation on the CJ1W-DA08C. All eight channels share a common return pathway. If your field actuators or drives operate with differing local electrical ground potentials, ground loops can develop, leading to signal instability, measurement drift, or hardware degradation. In systems requiring high-integrity isolation across channels, external 1:1 signal isolators must be mounted inline. Additionally, pay close attention to loop impedance: any load exceeding 350 Ohm will cause current clipping and lead to output calibration errors.

Commissioning & Wiring Tips

To minimize high-frequency noise interference, always run analog output signals in shielded twisted-pair cables, routing them through dedicated low-voltage wireways isolated from high-voltage AC lines. Terminate the cable shields exclusively at one end (preferably the cabinet ground bar near the PLC) to eliminate the risk of noise induction from ground loop currents. Use the detachable terminal block to complete all wiring adjustments on a bench before snapping the module onto the rack, protecting the sensitive internal photocoupler circuits from accidental contact with stray wire strands or active voltage pins.

Installation Guidelines

CRITICAL WARNING:

Ensure that both the primary PLC backplane power supply and the external 24 VDC power supply connected to the unit are completely de-energized prior to inserting, extracting, or wiring the module. Performing actions while powered (hot-swapping) can induce physical damage to the module backplane connections or cause connected field actuators to activate unexpectedly.

1
Locate the mounting slot on your CJ-series rack and insert the top hook of the module into the DIN rail guide, then rotate it downward until the connector fits firmly into the backplane.
2
Secure the module in place using the yellow locking slide indicators located at the top and bottom of the unit casing.
3
Configure the hardware unit number rotary dials on the front panel to ensure they match the corresponding address assignments programmed in CX-Programmer or Sysmac Studio.
4
Attach the pre-wired 18-point detachable terminal block, torque the M3 screws to 0.5 Nm, and double-check the 24 VDC external power feed polarity before energizing the system.
Loading product navigation…

Can the CJ1W-DA08C handle voltage outputs?

No. The CJ1W-DA08C is designed exclusively for 4 to 20 mA current loop analog signals. For voltage applications, consider models like the CJ1W-DA08V.

Are the eight channels on this Omron module isolated from one another?

No. There is photocoupler isolation between the internal controller circuitry and the I/O terminals, but individual analog output channels share a common ground reference.

What is the maximum allowed resistance load for each current channel?

The maximum permissible load resistance per output channel is 350 Ohm. Exceeding this limit will cause current loop saturation and lead to inaccurate signal outputs.

What happens to the outputs if the PLC CPU transitions to PROGRAM mode?

The module features an Output Hold function that allows users to configure the output state to either clear (CLR), retain the last value (HOLD), or ramp to the maximum limit (MAX).

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...