1 из 1

Honeywell 51196655-100 TDC 3000 Power Supply Module

Honeywell 51196655-100 TDC 3000 Power Supply Module

Остался в наличии только 5 товар(ы)
  • Производитель: Honeywell

  • Номер продукта: 51196655-100

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: TDC 3000 Power Supply Modules

  • Оплата: Т/Т, Western Union

  • Вес: 3000г

  • Размеры: 320 mm x 240 mm x 110 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Reliable DC system power within legacy distributed control networks is maintained by the Honeywell 51196655-100, a robust chassis-mounted Power Supply Module engineered for integration with the Honeywell TDC 3000 DCS architecture. This assembly provides regulated operating voltages directly to local node backplanes, ensuring continuous operation of critical control cards, network interfaces, and processor modules. The unit features built-in overcurrent protection and configurable clock reference settings to support precise hardware synchronization across distributed nodes.

Features

  • Dual-Clock Sync Support: Features board jumper J102 for manual switching between Internal (line frequency) and External clock operation.
  • Integrated Protection: Overvoltage, short-circuit, and thermal protection safeguards downstream backplane components.
  • Industrial Heat Dissipation: Built with high-surface-area heat sinks to enable continuous operation in enclosed control cabinets.
  • Chassis Plug-In Design: Rugged form factor with high-reliability rear pin connectors for direct insertion into TDC 3000 card cages.

Applications

  • TDC 3000 Nodes: Clean power delivery for Network Interface Modules (NIM) and Local Control Network (LCN) architectures.
  • Refining and Petrochemical Processing: High-availability process automation power systems.
  • Sequence of Events (SOE) Systems: Clock-synchronized field event logging installations.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Part Number / SKU 51196655-100
System Compatibility TDC 3000 Distributed Control System (DCS)
Clock Reference Selector Jumper J102 (INT / EXT options)
Default Clock Jumper Setting INT (Internal line frequency)
Mounting Type TDC 3000 System Card Cage Slot
Country of Origin United States
Shipping Weight (Calculated) 3.0 kg (6.61 lbs)
Package Dimensions (Calculated) 320 mm x 240 mm x 110 mm

Connections and Interfaces

Terminal / Component Function / Circuit Assignment
Jumper J102 (INT position) Pins configured for Internal Line Frequency Clock (standard DCS nodes)
Jumper J102 (EXT position) Pins configured for External System Clock (required for SOE NIM setups)
Rear Edge Connector Pinout Dedicated power backplane interface with heavy-duty DC supply pins

Empirical Engineering Insights

Alternative Models & Compatibility

This module serves as a direct drop-in replacement for legacy TDC 3000 card-file power configurations. When swapping power supplies, verify that the module's revision matches the backplane grounding scheme of your existing card rack to prevent potential ground loop disturbances.

Application Pitfalls & Engineering Notes

By default, all replacement 51196655-100 power supplies are shipped from stock with jumper J102 pinned to the Internal (INT) position. This is suitable for general nodes. If your architecture relies on Sequence of Events (SOE) tracking, the Clock Master, Clock Slave, and Network Interface Modules (NIMs) with specific SOE requirements must be verified and manual adjustments made to external clock configurations.

Commissioning & Wiring Tips

Always check the physical state of the J102 jumper header before sliding the module into the chassis guide rails. If the clock mode is mismatched relative to neighboring nodes, it can lead to synchronization dropouts or network time stamps showing system fault codes during high-traffic intervals.

Installation Guidelines

CRITICAL WARNING

Disconnect all primary AC/DC power sources feeding the card cage before attempting to insert or remove this power supply module. Live insertion of power cards can result in high-voltage arcing on the backplane, causing permanent physical damage to adjacent process control processors or interface cards.

1

Verify that the source power to the specific card-cage section has been shut down and locked out.

2

Check and position the J102 configuration jumper for either INT or EXT clock operations to align with your facility's system layout.

3

Align the PCB edges carefully with the card guides inside the TDC 3000 rack enclosure.

4

Gently but firmly push the module straight back until the rear connectors fully engage with the backplane receptacle, then tighten any locking mechanism or chassis retention screws.

Loading product navigation…

What is the function of the J102 jumper on the 51196655-100 power module?

The J102 jumper configures the system clock reference mode. The default INT setting uses the internal line frequency clock, while the EXT setting prepares the node for an external clock source.

When must the 51196655-100 clock jumper be set to external?

The EXT (external) clock setting is required on the NIM clock master, clock slave, and any Network Interface Modules (NIMs) that execute Sequence of Events (SOE) tracking protocols.

Can I hot-swap this power supply while the card file is active?

No. Live hot-swapping can damage the high-density backplane contacts and corrupt nearby processing modules. The card cage must be fully de-energized before mounting or removing the power supply.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Электрические приводы для замены жидкостей: практическое руководство

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...