1 из 1

ProSoft PLX31-PND-MBS4 PROFINET Device to Modbus Serial Gateway

ProSoft PLX31-PND-MBS4 PROFINET Device to Modbus Serial Gateway

Остался только 10 товар(ы) на складе
  • Производитель: ProSoft

  • Номер продукта: PLX31-PND-MBS4

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: Industrial Communication Gateways

  • Оплата: Т/Т, Western Union

  • Вес: 1500г

  • Размеры: 13.67 x 5.05 x 11.13 cm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Interfacing high-speed Ethernet-based PROFINET networks with legacy serial field devices is managed efficiently by the ProSoft PLX31-PND-MBS4, a specialized four-port communication gateway. This hardware facilitates bidirectional data exchange between controllers on a PROFINET network and Modbus serial devices. Featuring four independent, fully isolated serial ports, the gateway acts as a PROFINET Class A Device, supporting substantial data transfer volumes of up to 1440 bytes input and 1440 bytes output. Its robust, DIN-rail-mountable industrial enclosure and wide temperature rating make it suitable for continuous service in harsh control environments.

Features

  • Four Active Serial Ports: Each port is independently configurable to support Modbus RTU or Modbus ASCII protocol architectures.
  • Flexible Mode Settings: Supports Modbus Master or Modbus Slave operational modes per port, enabling simultaneous polling of sensors and serving data to multiple hosts.
  • High Data Throughput: Handles up to 1440 bytes of cyclic input data and 1440 bytes of cyclic output data for large-scale telemetry acquisition.
  • Acyclic Data Integration: Supports both Cyclic Real-time (RT) and Acyclic Data exchanges to pass diagnostic and acyclic parameters smoothly.
  • Electrical Isolation: Integrated Ethernet port features 1500 Vrms isolation to protect the internal processing logic from electrical surges and ground loops.
  • Broadcast Storm Resiliency: Hardened against industrial network traffic issues with dynamic broadcast storm limits of up to 5000 ARP frames-per-second.

Applications

  • Substation Telemetry: Connecting Modbus-based power quality analyzers, multifunction meters, and protection relays to a central PROFINET PLC.
  • Process Skid Integration: Linking legacy Modbus-enabled flow computers, valve manifolds, and temperature controllers to modern DCS platforms.
  • Infrastructure Monitoring: Interfacing remote pump controllers, gas detection systems, and variable frequency drives over serial lines into municipal water or oil and gas control networks.

Technical Specifications

Parameter Value / Specification
Manufacturer ProSoft Technology
Model Reference PLX31-PND-MBS4
PROFINET I/O Capacity 1440 bytes Input, 1440 bytes Output
PROFINET Driver Type Class A Device
Number of Serial Ports 4 isolated ports
Modbus Command Lists Up to 100 commands per Master port (configurable Function Codes)
Nominal Supply Voltage 24 VDC (10 to 36 VDC permitted limits)
Current Consumption 300 mA at 24 VDC nominal (610 mA maximum)
Operating Temperature -25 degC to 70 degC (-13 degF to 158 degF)
Storage Temperature -40 degC to 80 degC (-40 degF to 176 degF)
Relative Humidity 5% to 95% non-condensing RH
Ethernet Isolation 1500 Vrms, 50 to 60 Hz for 60 seconds (IEC 60950)
Mechanical Dimensions 13.67 x 5.05 x 11.13 cm (H x W x D)
Shipping Weight 1.50 kg

Connections and Interfaces

Port / Terminal Connector Type Signal Assignment
Ethernet Port RJ45 PROFINET Network / Config; 10/100 Mbps Base-TX
Serial Ports 1 - 4 DB9 Male (with terminal adapters) RS-232, RS-422, or RS-485 configurable modes
Power Input 3-Pin J180 Screw Terminal Block Positive (V+), Negative (V-), Protective Ground (GND)

Empirical Engineering Insights

Alternative Models & Compatibility

This unit replaces older multi-gateway systems that required separate PROFINET to Modbus RTU interface modules. By combining four distinct serial ports onto a single IP address, it decreases PROFINET node counts and simplifies PLC hardware configurations. Note that older configuration files from single-port models must have their register mappings offset properly to utilize the 4-port memory structure without overlap.

Application Pitfalls & Engineering Notes

A common issue occurs when configuring multiple Modbus Master commands. If a slave device drops offline, the Modbus polling cycle can experience long timeouts, slowing down update speeds across that entire port. Set your Modbus timeouts and retry parameters precisely in ProSoft Configuration Builder (PCB) to prevent slow network refresh rates.

Commissioning & Wiring Tips

When utilizing RS-485 multidrop configurations, remember to terminate the physical bus. Use the provided DB9 to screw terminal adapters to install 120-ohm termination resistors across the TX/RX+ and TX/RX- lines at the end of each physical serial segment. Keep your signal ground reference tied to earth at only one single point to avoid destructive ground-loop noise.

Installation Guidelines

CRITICAL WARNING: Prior to attempting hardware installation, servicing, or terminal wiring, ensure all 24 VDC incoming power sources are completely de-energized. Failure to follow industrial lock-out/tag-out procedures can result in terminal damage, logic lockup, or control network dropouts.
1
Mount the module firmly to a 35mm DIN rail with proper orientation, ensuring adequate air gap clearance around ventilation slots.
2
Connect the protective earth ground wire to the designated grounding terminal, and then connect the 24 VDC power supply using the J180 plug.
3
Insert the CAT5e/CAT6 Ethernet cable into the isolated RJ45 port and wire your serial lines to the serial DB9 connectors using shielded cabling.
4
Power up the system, launch ProSoft Configuration Builder to define your network settings, and assign register tables for your PROFINET master controller.
Loading product navigation…

What is the maximum cyclic data payload capacity supported by the PLX31-PND-MBS4?

This gateway supports up to 1440 bytes of input data and 1440 bytes of output data for cyclic real-time (RT) data exchanges as a PROFINET Class A device.

Can I configure each of the four serial ports independently?

Yes. Each serial port operates independently and can be configured as either a Modbus RTU/ASCII Master or Slave, complete with custom baud rates, timeouts, and command tables.

What are the power requirements for this gateway?

The gateway operates on a nominal 24 VDC power supply, but tolerates input voltages between 10 and 36 VDC. Typical current consumption is 300 mA at 24 VDC.

Does this module support both RS-232 and RS-485 serial communication?

Yes. All four serial ports can be individually wired to support RS-232, RS-422, or 2-wire/4-wire RS-485 communication interfaces.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...