1 из 1

ProSoft MVI56-MNETR ControlLogix Modbus TCP/IP Interface Module

ProSoft MVI56-MNETR ControlLogix Modbus TCP/IP Interface Module

Остался только 10 товар(ы) на складе
  • Производитель: ProSoft

  • Номер продукта: MVI56-MNETR

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: PLC Communication Modules

  • Оплата: Т/Т, Western Union

  • Вес: 450г

  • Размеры: 25.0 cm x 20.0 cm x 8.0 cm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Integrating Modbus TCP/IP communications directly into Rockwell Automation ControlLogix systems, the ProSoft MVI56-MNETR provides a specialized high-performance network interface utilizing a reduced data block structure. This module operates as an in-chassis slot solution, enabling ControlLogix processors to interface seamlessly with Modbus TCP/IP-compatible field instruments, SCADA systems, and programmable controllers. Designed specifically for architectures with constrained memory mapping or remote I/O limitations, the reduced data block configuration limits the backplane I/O transfer size to 240 words of input and 240 words of output data, making it highly compatible with remote I/O racks over ControlNet or EtherNet/IP adaptors.

Features

  • Reduced Data Block Structure: Limits I/O data transfers to 240 words input/240 words output to support remote rack installations.
  • Multi-Protocol Flexibility: Concurrently supports both Modbus TCP/IP Client (Master) and Server (Slave) configurations.
  • High Isolation Security: 1500 V rms electrical isolation protects the ControlLogix backplane from external network transient faults.
  • Optimized Diagnostic LEDs: Front-panel indicators provide real-time status updates for module operation, backplane transfer, and serial/Ethernet port activity.
  • Network Resiliency: Integrated broadcast storm protection mitigates network degradation under high-volume ARP frame scenarios.

Applications

  • Remote I/O rack communication over ControlNet or EtherNet/IP.
  • SCADA and HMI integration across plant networks.
  • Substation automation and power monitoring network connections.
  • Interfacing with variable frequency drives, flow meters, and external PLCs.

Technical Specifications

Parameter Specification
Manufacturer ProSoft Technology
Model Series MVI56 ControlLogix Platform
Backplane Current Draw 800 mA at 5 Vdc; 3 mA at 24 Vdc
Operating Temperature 0 degC to 60 degC (32 degF to 140 degF)
Storage Temperature -40 degC to 85 degC (-40 degF to 185 degF)
Relative Humidity 5% to 95% (non-condensing)
Vibration Resistance 5 g from 10 Hz to 150 Hz
Shock Operational 30 g operational; 50 g non-operational
Ethernet Port 10/100 Base-T RJ45 Connector
Electrical Isolation 1500 V rms at 50 to 60 Hz for 60 s (IEC 60950)
Broadcast Storm Resiliency Less than or equal to 5000 ARP frames-per-second
Net Weight 0.45 kg
Shipping Weight (Calculated) 1.50 kg
Package Dimensions (Calculated) 25.0 cm x 20.0 cm x 8.0 cm

Connections and Interfaces

Interface Port Description / Function
Ethernet Port (RJ45) Primary 10/100 Mbps Modbus TCP/IP connection. Utilizes Cat5e or Cat6 cabling.
CFG Port (RJ45) Configuration port. Interfaces via RJ45 to DB-9M connection for diagnostics and firmware utility software setup.

Empirical Engineering Insights

Alternative Models & Compatibility

It is vital to distinguish the MVI56-MNETR from the standard MVI56-MNET. The MVI56-MNET utilizes a larger 5000-word block size, which is unsupported by several common remote I/O network adapters. If your system architecture places the communication interface in a remote rack connected via ControlNet (e.g., 1756-CNB/CN2) or EtherNet/IP (e.g., 1756-ENBT/EN2T), the "R" (Reduced Data Block) variant is mandatory to prevent connection sizing faults.

Application Pitfalls & Engineering Notes

When configuring large networks, ensure the broadcast traffic does not exceed the hardware limit of 5000 ARP frames-per-second. Networks shared with enterprise data or unmanaged switches often suffer from high broadcast traffic, which can trigger the internal safety isolation of the MVI56-MNETR's ethernet controller, causing brief, intermittent offline faults. Always isolate industrial control paths onto distinct virtual networks (VLANs) or managed switches.

Commissioning & Wiring Tips

Initial configuration requires ProSoft Configuration Builder (PCB) software. Connect via the provided RJ45-to-DB9 cable to the configuration serial port prior to system insertion if your default IP network segment is different. Ensure standard RS-232 serial parameters are matched on the configuration computer to establish stable firmware terminal access.

Installation Guidelines

CRITICAL WARNING: electrical discharge hazard

Remove all system operational power from the ControlLogix chassis before inserting or removing the MVI56-MNETR interface. Inserting or removing the card while the backplane is energized can cause irreversible logical disruption to the PLC processor or damage the backplane contact connector pins.

1 Ensure the ControlLogix system is de-energized.
2 Align the module circuit card with the plastic guides of the target slot in the ControlLogix chassis.
3 Firmly slide the module inward until it seats securely into the chassis backplane.
4 Secure the top and bottom chassis tabs on the module front-plate.
5 Connect the shielded RJ45 Ethernet communication cable to the primary ports and power on the chassis.
Loading product navigation…

What is the difference between the MVI56-MNET and MVI56-MNETR?

The MVI56-MNETR is the 'Reduced Data Block' version. It uses a maximum configuration of 240 input and 240 output words to communicate through standard backplanes. This enables the module to be utilized in remote I/O racks where network adaptors limit larger data block configurations.

Can the module operate as both a Modbus TCP/IP Client and Server concurrently?

Yes, the MVI56-MNETR interface supports simultaneous operations, allowing it to act as both a Modbus Client (Master) requesting data and a Modbus Server (Slave) responding to command requests on the network.

Is software required to configure the interface parameters?

Yes, configuration requires the free ProSoft Configuration Builder (PCB) software tool. Configuration files are downloaded to the module via the RS-232 serial configuration port using the supplied RJ45-to-DB9 cable.

What happens if Ethernet broadcast storm activity exceeds 5000 frames per second?

The module contains hardware protection that can drop or limit packets when broadcast frames exceed this limit to prevent module locking, ensuring backplane communications remain running.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...