The X20CM0985 (X20CM0985) is a sophisticated 3-channel analog input module designed for comprehensive power and energy measurement within the B&R X20 System. This module is engineered to monitor 3-phase electrical networks, supporting direct voltage inputs of up to 480 VAC and current inputs of 1 A or 5 A AC via external transformers. In energy-intensive industries such as plastics processing, metal fabrication, and large-scale manufacturing, the X20CM0985 provides the critical data required for load management, predictive maintenance, and energy efficiency auditing. By delivering high-precision measurements of active, reactive, and apparent power directly to the PLC, it enables engineers to optimize machine performance and reduce operational overhead through real-time grid analysis.

Technical Configuration

The X20CM0985 integrates complex signal processing within the standard X20 form factor. It features three independent channels for simultaneous current and voltage measurement, allowing for the calculation of phase angles and harmonic distortion. The internal hardware is robust, consuming 1.05 W from the X20 bus and 4 W for the internal I/O circuitry. It is designed for high-voltage environments with a rated input capacity of 120 VAC to 480 VAC, making it compatible with most global industrial power grids. The module utilizes specialized A/D converters to handle the AC waveforms, ensuring that peak values and RMS calculations are performed with minimal latency. With an IP 20 protection rating, it is intended for installation in controlled electrical cabinets where space-saving and modularity are prioritized.

Technical Specifications

Feature Specification
Model X20CM0985
Brand B&R (Bernecker + Rainer)
Module Type Analog Input / Energy Measurement
Number of Channels 3 (Current and Voltage)
Voltage Input Range 120 VAC to 480 VAC
Current Input Range 1 A or 5 A AC
Bus Power Consumption 1.05 W
Internal I/O Consumption 4 W
Degree of Protection IP 20
Operating Temp 0 to 55 deg C
Dimensions 12.5 x 99 x 75 mm
Shipping Weight 2.0 kg

Technical FAQs

Can the X20CM0985 measure power in both 3-phase and single-phase systems?

Yes, the module is designed for 3-phase systems but can be configured to monitor three individual single-phase circuits. This flexibility allows for the monitoring of multiple high-load single-phase actuators within a single machine using only one module.

Does this module require external current transformers (CTs)?

Yes, for current measurement, the X20CM0985 must be interfaced with external current transformers that provide a secondary output of either 1 A or 5 A AC. Direct connection of high-current power lines to the module will result in immediate hardware failure.

What specific electrical parameters can be calculated by the X20CM0985?

Beyond standard voltage and current, the module provides data for active power (W), reactive power (var), apparent power (VA), energy consumption (Wh), and power factor (cos phi). It also supports frequency measurement and basic harmonic analysis.


Engineering & Installation Guide

  • Current Transformer Polarity: When wiring the 1 A or 5 A current inputs, strict adherence to the S1 (k) and S2 (l) polarity is essential. Reversing the polarity on a single phase will result in incorrect power factor readings and negative energy calculations for that specific phase.

  • Voltage Path Protection: Always install 3-pole circuit breakers or fuses (typically rated at 1 A to 2 A) in the voltage measurement path between the power line and the X20CM0985. This protects the module and the X20 backplane from catastrophic failure in the event of a line-to-line short circuit within the measurement loop.

  • Shielding and Grounding: Given the proximity to high-voltage lines, the X20CM0985 is susceptible to electromagnetic interference. Ensure the X20 bus module is properly snapped onto a grounded DIN rail. Use shielded cables for the current transformer secondaries and ground the shield at a single point to prevent circulating ground currents from skewing measurement accuracy.

 

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
สหรัฐอเมริกา
Power source
ใช้พลังงานไฟฟ้า

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...