1 จาก 3

IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module with HART

IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module with HART

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC695ALG626

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Analog Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 3.5cm x 13.5cm x 13.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

IC695ALG626 (IC695ALG626) is a high-resolution analog input module designed for GE Fanuc PACSystems RX3i control platforms. The module provides 16 single-ended or 8 differential analog input channels with integrated HART 5.0 communication capability. Engineers deploy this module in turbine control systems, refinery process skids, power generation monitoring, and critical plant instrumentation where accurate analog acquisition is required.

The design integrates four internal HART modems and supports simultaneous analog and digital device diagnostics. Software configuration eliminates hardware jumpers and simplifies commissioning. Built-in autocalibration, advanced filtering, and high noise rejection maintain measurement stability in electrically harsh environments. The module supports voltage and current ranges including 4 to 20 mA loops commonly used in field transmitters. High resolution 24 bit ADC conversion ensures precise process feedback, reducing control drift and unexpected shutdown risks.

Technical Configuration

The IC695ALG626 installs into RX3i Universal Backplane and communicates directly with RX3i CPUs. Each channel supports independent configuration for voltage or current inputs. Four internal HART modems multiplex channel groups to enable device diagnostics without additional hardware.

The module supports:

  • 16 single ended or 8 differential inputs
  • HART 5.0 communication per channel group
  • 24 bit ADC conversion with floating point output
  • Software selectable filters from 8 Hz to 500 Hz
  • Per channel scaling and alarm configuration
  • Autocalibration at startup
  • Open circuit detection and fault reporting

Voltage and current ranges include:

  • 0 to 20 mA
  • 4 to 20 mA
  • plus minus 20 mA
  • plus minus 10 V
  • 0 to 10 V
  • plus minus 5 V
  • 0 to 5 V
  • 1 to 5 V

Technical Specifications

Parameter Specification
Model IC695ALG626
Brand GE Fanuc
Series PACSystems RX3i
Module Type Analog Input with HART
Channels 16 single ended or 8 differential
ADC Resolution 24 bit
Input Ranges Voltage and current configurable
HART Support Version 5.0
Backplane Power 600 mA at 5 VDC
Power Dissipation 7.35 W maximum
Isolation 250 VAC continuous
Input Impedance Greater than 100 kOhm
Overvoltage Protection plus minus 60 VDC continuous
Overcurrent Protection plus minus 28 mA continuous
Accuracy up to 0.05 percent of range
Operating Temperature 0 to 60 deg C
Dimensions Standard RX3i module
Origin USA
Weight Approx 0.32 kg

Technical FAQs

Does IC695ALG626 support HART communication on every channel?
Yes. The module supports HART communication through four internal modems. Channels are multiplexed into modem groups.

Which CPU is required for this module?
RX3i CPU firmware version 3.5 or later is required. Machine Edition 5.5 or newer configures the module.

Can the module work with differential inputs?
Yes. Configure the module for 8 differential inputs through software configuration.

What terminal blocks are compatible?
IC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132 terminal blocks are supported.


Engineering & Installation Guide

Use shielded twisted pair wiring for 4 to 20 mA HART loops. Ground the shield at one end only to avoid ground loops.

Distribute HART devices across channel groups 1, 5, 9, and 13 to minimize update time. This reduces multiplex delay.

Install the module in slots with adequate airflow. High channel count current mode increases thermal load.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

IC695ALG626 GE Fanuc PACSystems RX3i Analog Input Module with HART

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...