1 จาก 1

KL4021 | BECKHOFF | 1-Channel Analog Output Terminal 4-20 mA

KL4021 | BECKHOFF | 1-Channel Analog Output Terminal 4-20 mA

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL4021

  • Country of origin:เยอรมนี

  • Product Type: Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The KL4021 (KL4021) is a precision 1-channel analog output terminal designed for the Beckhoff Bus Terminal system, delivering a standardized 4 to 20 mA current signal. Engineered for high-reliability process control, this module is the industry standard for interfacing with proportional valves, dampers, and frequency inverters in water treatment, HVAC, and chemical processing plants. With its 12-bit resolution and a low output error of less than ±0.1 percent, the KL4021 ensures stable and repeatable actuator positioning. Its robust design is further validated by extensive marine (DNV GL) and hazardous area (ATEX/IECEx) certifications, making it a versatile choice for both onshore industrial sites and offshore installations.

Technical Configuration

The hardware architecture of the KL4021 is optimized for the K-bus protocol, featuring a single-ended 1-wire connection technology. The terminal draws its 24 VDC supply via the internal power contacts, though it optionally supports 15 VDC operation when used with a KL9515 power supply terminal for specific energy-efficient or legacy requirements. The module provides 500 V electrical isolation between the internal K-bus logic and the field signal voltage, safeguarding the central controller from field-side electrical surges. The process image is presented as a 1 x 16-bit data value, and the unit is designed for "plug-and-play" operation, requiring no complex hardware addressing or manual configuration settings.

Technical Specifications

Feature Specification
Model KL4021
Brand BECKHOFF
Origin Germany
Number of Outputs 1
Signal Current 4 to 20 mA
Resolution 12 bit
Load < 500 Ohms
Conversion Time approx. 1.5 ms
Output Error < +/- 0.1 percent (relative to end value)
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption (K-bus) typ. 60 mA
Operating Temperature 0 to +55 Celsius
Approvals CE, UL, ATEX, IECEx, DNV GL

Technical FAQs

Can I use the KL4021 for a 0-20 mA application?

The KL4021 is hardware-optimized for 4-20 mA to provide "live-zero" monitoring. For applications strictly requiring 0-20 mA, you should select the KL4011. Using the KL4021 for 0-20 mA would result in the inability to output signals below 4 mA.

What is the maximum distance the current signal can travel?

Because the 4-20 mA signal is a current loop, it is highly resistant to voltage drops and EMI. The distance is primarily limited by the total loop resistance; as long as the total resistance (wire + actuator) remains under 500 Ohms, the terminal will maintain its specified accuracy over several hundred meters.

How do the 12-bit resolution and 16-bit process image interact?

The 12-bit output value is mapped into the 16-bit data word of the K-bus. Typically, the value is left-aligned. In your PLC program, you will scale your process variable (e.g., 0-100%) to the corresponding digital range (typically 0 to 32767 or 4095 depending on configuration) to drive the output.


Engineering & Installation Guide

  • Shielding for Precision: Although 4-20 mA is robust, for the highest accuracy (especially in maritime or Ex zones), use shielded twisted-pair (STP) cables. Connect the shield at only one end—typically at the control cabinet's earth bar—to prevent ground loops from introducing signal offsets.

  • Load Matching: Verify that your actuator's input impedance does not exceed 500 Ohms. If the load is too high, the terminal will be unable to drive the full 20 mA, resulting in a "saturated" output that does not match your PLC command.

  • Power Supply Stability: While the terminal can run on 24 VDC via power contacts, ensure your power supply has sufficient headroom. The KL4021 consumes roughly 30 mA plus the actual loop current (up to 20 mA). In a large terminal strand, calculate the total current to ensure the bus coupler’s power contacts (max 10 A) are not overloaded.

  • Hazardous Area Mounting: For ATEX/IECEx Zone 2 compliance, the KL4021 must be installed in an enclosure providing at least IP54 protection. Ensure that all wiring is secured against accidental disconnection, as per the "Ex nA" and "Ex ec" safety requirements.

 

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาว
Country of origin
เยอรมนี
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...