1 จาก 1

Mitsubishi Electric FR-A840-55K-1 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-55K-1 FR-A800 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A840-55K-1

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 44000g

  • Dimensions: 550 mm x 435 mm x 250 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Optimizing heavy-duty industrial machinery performance, the Mitsubishi Electric FR-A840-55K-1 is a premium three-phase vector control variable frequency drive engineered for high-torque applications up to 55 kW. This high-performance FR-A800 series inverter features an integrated FM pulse terminal for precise monitoring and supports advanced Real Sensorless Vector Control (RSVC) to achieve exceptional speed and torque accuracy. Designed to integrate seamlessly into complex factory automation architectures, the unit provides reliable power conversion, extensive communications support, and robust energy-saving features to maximize process uptime.

Features

  • Advanced Real Sensorless Vector Control and PM sensorless vector control for unmatched motor shaft performance.
  • Built-in FM pulse train terminal providing high-resolution analog output configurations for system monitoring.
  • Integrated multi-port external communication interfaces supporting RS-485, RS-422, and RS-232 protocols.
  • Multi-rating flexibility to adapt to both Normal Duty (ND) and Light Duty (LD) operational demands.
  • Compliance with global functional safety standards including safety stop functions to minimize risk in manual intervention areas.

Applications

  • High-capacity material handling systems including cranes, hoists, and continuous conveyors.
  • Industrial fan systems, heavy-duty blowers, and municipal water supply pumping systems.
  • Continuous manufacturing machinery such as extruders, mixers, and winding systems.
  • Automated machine tool spindles and deep-well oil recovery pumping applications.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Reference FR-A840-55K-1
Series FR-A800
Applicable Motor Capacity 55 kW
Input Voltage Class Three-Phase 400 V
Output Rated Voltage Three-phase 380 to 500 V
Output Rated Current 110 A
Output Capacity 84 kVA
External Communications RS-232 / RS-422 / RS-485
Output Terminal Type FM Term (Pulse Train Output)
Approvals & Standards CE, UL, cUL, RoHS compliant
Dimensions (H x W x D) 550 mm x 435 mm x 250 mm
Product Weight 44 kg

Connections and Interfaces

Terminal Designation Functional Assignment
R/L1, S/L2, T/L3 Three-Phase AC Power Input Connection
U, V, W Three-Phase AC Output to Motor
FM Pulse Train Output Terminal for Monitoring
SD / SE Contact Input / Sensor Common Ground Terminals
RJ-45 Connector PU / RS-485 Communication Port

Alternative Models & Compatibility

The FR-A840-55K-1 serves as a direct functional replacement for legacy FR-A740-55K series drives. When replacing an older A700 series unit, parameter configurations can be transferred using Mitsubishi FR Configurator2 software. Note that although physical cabinet footprints are highly aligned, cooling fan clearances and terminal block configurations should be verified prior to structural integration.

Application Pitfalls & Engineering Notes

To maintain optimal thermal performance under continuous duty in enclosed control cabinets, do not exceed an ambient temperature of 50 Celsius without applying appropriate derating guidelines. When running this unit with high carrier frequencies to eliminate motor audible noise, ensure that the output current rating is adjusted downward according to the manufacturer derating curves to avoid thermal over-current trips (E.THT / E.OC1).

Commissioning & Wiring Tips

For installations utilizing control cable runs longer than 30 meters to the FM pulse terminal, use shielded twisted-pair (STP) cabling. Ensure that the cable shield is grounded strictly at the drive-end ground point (PE terminal) to prevent industrial high-frequency noise from inducing signal distortion or false logic transitions. Always separate control signal wiring from high-power 400 V AC inputs and motor output cabling by a minimum clearance of 30 cm.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical inputs before initiating installation or service on this equipment. High-voltage capacitors retain a lethal residual charge. Wait a minimum of 10 minutes after main power disconnection and measure the DC link voltage across terminals P/+ and N/- to verify it is below 45 V DC before touching terminal blocks or internal wiring.

1

Mount the drive vertically inside a dust-free, vibration-isolated cabinet. Ensure there is at least 100 mm of clearance above and below the drive housing for unhindered convective cooling airflow.

2

Connect the mains power input lines to terminals R/L1, S/L2, and T/L3, and connect the motor power cables to terminals U, V, and W. Tighten all terminal screws to the manufacturer-specified torque limits using a calibrated torque wrench.

3

Route control and pulse output signal lines through separate conduits to avoid electromagnetic interference. Ground the motor frame directly to the drive ground terminal, and ground the drive housing to the central protective ground bar of the facility.

What does the FM terminal designation indicate on the FR-A840-55K-1?

The FM term suffix indicates the drive is equipped with a pulse train monitoring output. It delivers a fast, continuous pulse train signal representing variables such as motor speed, output frequency, or current.

Can I run this 55 kW drive with a standard single-phase power supply?

No, this unit is designed exclusively for three-phase 380 V to 500 V AC power grids. Attempting to power it on a single-phase supply will trigger low-voltage phase-loss faults and damage internal rectifiers.

Is the FR-A840-55K-1 backward compatible with the older FR-A740 series?

Yes, it functions as a modern replacement. Parameter conversion and migration can be handled using the FR Configurator2 application, though minor panel-mount dimensional clearances should be cross-referenced.

How long must I wait after powering off before safe wiring can begin?

You must wait at least 10 minutes to allow the high-capacity internal DC bus capacitors to discharge safely below 45 V DC. Always verify using a multi-meter at the P/+ and N/- terminals before servicing.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...