Mitsubishi Electric FX5-ENET MELSEC iQ-F Series Network Module

Mitsubishi Electric FX5-ENET MELSEC iQ-F Series Network Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX5-ENET

  • Country of origin:สหรัฐอเมริกา

  • Product Type: PLC Network Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 12.5 cm x 11.0 cm x 6.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Delivering expanded Ethernet connectivity to MELSEC iQ-F controllers, the Mitsubishi Electric FX5-ENET functions as a dedicated, high-performance network interface module. This module enables host PLCs to integrate seamlessly into complex plant-wide architectures by providing an independent Ethernet port that supports simultaneous multi-protocol communications. It allows industrial engineers to isolate network traffic by routing local HMI and supervisory SCADA systems through separate physical subnets, preventing data bottlenecks on the CPU's primary port. Designed for reliable data transmission, the module natively processes CC-Link IE Field Network Basic, SLMP (Seamless Message Protocol), and standard socket communication protocol configurations.

Features

  • Dual-Subnet Isolation: Enables a second, independent IP routing path to separate machine-level I/O from factory-level networks.
  • Multi-Protocol Support: Concurrently processes CC-Link IE Field Basic, SLMP, MC Protocol, FTP client/server, and SNTP time synchronization.
  • High-Capacity Data Handling: Supports up to 32 simultaneous connection sockets for complex SCADA and database applications.
  • Diagnostic Indicators: Features front-facing LED status indicators for quick visual troubleshooting of link activity, transmission speeds, and system errors.
  • Simple Configuration: Direct hardware setup and parameter mapping completed entirely within the GX Works3 engineering software environment.

Applications

  • High-density packaging machinery requiring independent HMI and SCADA communication links.
  • Automotive assembly cell integration utilizing CC-Link IE Field Network Basic for remote station control.
  • Water and wastewater remote telemetry systems using FTP file transfers for daily logging reports.
  • Material handling systems interfacing with third-party vision systems and barcode readers via raw TCP/UDP socket communication.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FX5-ENET
Product Series MELSEC iQ-F Series
Module Type Ethernet Network Module
Data Transmission Rate 100 Mbps / 10 Mbps (Auto-negotiation)
Communication Mode Full-Duplex / Half-Duplex
Interface Type RJ45 connector (1 port)
Maximum Cable Length 100 meters (segment length)
Maximum Connections 32 connections (total destination nodes)
Internal Power Consumption 110 mA at 24 V DC (supplied from system bus)
Compatible Controllers FX5U CPU, FX5UC CPU (requires bus conversion module)
Ambient Operating Temperature 0 to 55 degC
Country of Origin Japan
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 12.5 cm x 11.0 cm x 6.5 cm

Empirical Engineering Insights

Alternative Models & Compatibility

While the base FX5U CPU contains an onboard RJ45 Ethernet port, the FX5-ENET is specifically applied when network security mandates physically separated subnets or when your project exceeds the base CPU's native connection limits. Note that when mounting the FX5-ENET to an ultra-compact FX5UC CPU, you must install an FX5-CNV-BUS or FX5-CNV-BUSC bus conversion module prior to attaching this network block.

Application Pitfalls & Engineering Notes

When configuring CC-Link IE Field Network Basic, verify that the total cyclic transmission load does not saturate your network bandwidth. Because the FX5-ENET relies on the internal system bus for power, ensure that the total current draw of all connected extension modules does not exceed the remaining capacity of the 24 V DC service power supply integrated within the host CPU module.

Commissioning & Wiring Tips

To prevent high-frequency industrial noise from interrupting communication packets, always use double-shielded category 5e (STP) or higher Ethernet cabling. Ground the shield at the switch side, and confirm that the main PLC base unit is securely grounded to a Class D ground (grounding resistance of 100 ohms or less) via a dedicated, short copper grounding strap.

Installation Guidelines

CRITICAL WARNING:

Always disconnect and isolate all external AC and DC power supplies feeding the PLC rack before mounting, demounting, or wiring the FX5-ENET module. Failure to de-energize the entire system may result in permanent electronic component degradation, processor fault-states, or unexpected machinery startup.

1
Ensure the CPU module and all extension blocks are mounted on a clean, vibration-free, standard 35 mm DIN rail inside an IP54-rated metal enclosure.
2
Slide the FX5-ENET system bus connector firmly into the extension port of the preceding module until the locking tabs click fully into place.
3
Insert the RJ45 industrial Ethernet cable connector into the port located on the lower-front section of the module until it is securely latched.
4
Apply system power, open your GX Works3 configuration workspace, detect the newly attached module via the Module Configuration window, and write your network parameters directly to the CPU.

What is the primary benefit of adding the FX5-ENET module if the FX5U CPU already has an Ethernet port?

The module allows you to establish a secondary, physically isolated Ethernet network. This isolates automation device control loops from high-traffic plant networks, increases available sockets to 32 connections, and supports dedicated CC-Link IE Field Basic configurations.

Is an external 24 V DC power supply connection required for this module?

No, the FX5-ENET draws its operational power of 110 mA at 24 V DC directly from the host PLC's internal system bus connector.

Can this Ethernet module be used with FX5UC compact CPU units?

Yes, but it requires an FX5-CNV-BUS or FX5-CNV-BUSC bus conversion module to transition from the ultra-compact connector style to the standard extension bus connection.

What software is required to configure the network settings of the FX5-ENET?

Configuration, routing tables, and IP assignments are fully programmed using GX Works3, which is the standard engineering software platform for the MELSEC iQ-F series.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...