Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

Solo queda(n) 10 artículo(s) en stock
  • Fabricante: Yokogawa

  • Número de producto: AAT141-S00

  • País de origen:Japón

  • Tipo de producto: TC/mV Input Modules

  • Pago: Transferencia bancaria, Western Union

  • Peso: 200g

  • Dimensiones: 32.8 x 130 x 125.5 mm (W x H x D)

  • Puerto de envío: Xiamen

  • Garantía: 12 meses

Cantidad
Ver detalles completos

Description

The Yokogawa AAT141-S00 is a 16-channel isolated thermocouple and millivolt input module designed for FIO systems within CENTUM VP field control stations. It functions as a signal converter by inputting field temperature and voltage signals into internal data for the Field Control Station (FCS). The AAT141-S00 module receives signals from thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage spans ranging from -100 to 150 mV and -20 to 80 mV. It supports dual-redundant configuration and connects externally via a pressure clamp terminal block.

Features

  • 16 isolated input channels for thermocouple and mV signals.
  • Software-selectable TC/mV input types individually configured for CH1 to CH16.
  • Dual-redundant configuration capability.
  • Dedicated pressure clamp terminal external connection interface.
  • Software-configurable burnout detection (UP/DOWN/Not available) for all channels.

Applications

  • Process temperature monitoring using thermocouples.
  • Millivolt analog input signal interfacing in CENTUM VP FIO DCS environments.
  • High-reliability industrial control systems requiring isolated I/O modules.

Ordering Information

Model Suffix Codes Option Codes Description
AAT141     TC/mV Input Module (16-channel, Isolated)
Suffix -S   Standard type
  0   With no explosion protection
  0   Basic type

Technical Specifications

Category Item Specification
Basic Specifications Manufacturer Yokogawa
  Model AAT141-S00
  Number of Input Channels 16, isolated
Input Specifications Input Signal

TC: JIS C1602:1995, IEC584:1995 Type J, K, E, B, R, S, T, N


 

mV: -100 to 150 mV, -20 to 80 mV

  Switching Input Signals TC/mV can be set individually for CH1 to CH16
  Allowable Input Voltage +/-5 V
  Input Resistance (Power ON/OFF) 2 MOhm or larger
Performance Accuracy

+/-30 uV (TC)


 

+/-80 uV for span (-100 to 150 mV)


 

+/-30 uV for span (-20 to 80 mV)

  Reference Junction Compensation Accuracy Within +/-1 degC (varies depending on installation and ambient temperature)
  Allowable Total Resistance 1000 Ohm or less (signal source plus wiring)
  Effect of Signal Source Resistance +/-20 uV per 1000 Ohm (+/-40 uV in dual-redundant configuration)
  Temperature Drift

+/-80 uV/10 degC (-100 to 150 mV input)


 

+/-30 uV/10 degC (TC/-20 to 80 mV input)

  Data Update Period 1 s
  Burn-out Detection All channels can be set together (Not available/available UP/DOWN), Detection time: 60 s
Electrical & Insulation Withstanding Voltage Between input and system: 1500 V AC, for 1 minute
  Maximum Current Consumption 450 mA (5 V DC)
Physical Specifications Weight 0.2 kg
  External Connection Pressure clamp terminal

Installation Guidelines

  • Use a non-ground type thermocouple (TC) because the device is an isolated type module; using ground type TC on multiple channels causes temperature errors due to multi-point ground.
  • Ensure proper installation onto supported ESB, Optical ESB, or ER bus node units.
  • Maintain matching wiring resistance for signal cables to ensure measurement accuracy.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa AAT141-S00 CENTUM VP TC/mV Input Module (16-channel, Isolated)

What input signal types are supported by the module?

The module supports thermocouple types J, K, E, B, R, S, T, and N, as well as mV voltage inputs ranging from -100 to 150 mV and -20 to 80 mV.

Why must non-ground type thermocouples be used with this module?

Because the module is an isolated type, using a ground type thermocouple across multiple channels causes temperature measurement errors due to multi-point grounding.

What is the maximum current consumption for the device?

The maximum current consumption is 450 mA at 5 V DC.

Envío exprés global

  • Entrega estándar: 4-6 días hábiles vía DHL, FedEx y UPS.
  • Envío exprés: Despacho el mismo día para pedidos en stock realizados antes de las 2:00 PM (GMT+8).
  • Cobertura mundial: Servicio en más de 150 países, incluyendo entrega rápida a Arabia Saudita y Emiratos Árabes Unidos.

Devoluciones y Garantía

  • Garantía de 30 días: Se aceptan devoluciones de productos en stock en su embalaje original y sellado de fábrica.
  • Garantía de 12 meses: Cada componente industrial cuenta con nuestra garantía técnica profesional.

Los pedidos se procesan y entregan de lunes a viernes (excepto festivos).


Para conocer la elegibilidad completa, las tarifas de reposición y los detalles de devoluciones internacionales, por favor consulte nuestro sitio oficial Política de Reembolso y Devoluciones .

TECHNICAL SPECIFICATIONS

Country of origin
Japón

Productos vistos recientemente

Conocimientos técnicos

Modernización de las HMI Bailey INFI 90 Symphony que se ejecutan en OpenVMS Alpha

Una guía práctica para reemplazar estaciones de operación Bailey Symphony obsoletas que funcionan con OpenVMS Alpha. Compara la emulación de Alpha, la migración de OpenVMS a x86, la reimplementación...

Por qué los datos de mantenimiento son esenciales para la fiabilidad industrial

Los datos de mantenimiento conectan las órdenes de trabajo, las señales de los sensores, el historial de los activos, los costos y los conocimientos de los técnicos. Cuando se utilizan correctamente,...

Actuadores eléctricos diseñados para sustituir sistemas de potencia fluida: una guía práctica de automatización industrial

Este artículo explica cómo los actuadores eléctricos integrados, como la serie e-Actuator de SMC, están transformando el control de movimiento industrial al reemplazar los sistemas neumáticos e...

Operaciones matemáticas con OpenPLC para aplicaciones de automatización industrial

Este artículo explica cómo los sistemas PLC realizan operaciones matemáticas básicas, como suma, resta, multiplicación, división, módulo y exponenciación, en el ámbito de la automatización...

Lógica booleana avanzada con programación de PLC FBD: aplicaciones industriales prácticas más allá de la lógica básica

El artículo explica varias funciones avanzadas de lógica booleana utilizadas en la programación de PLC, más allá de las operaciones básicas AND, OR y NOT. Describe cómo herramientas como las tablas...

Lógica booleana en la programación de PLC: cómo entender las puertas lógicas FBD

La lógica booleana es la base de todo programa de PLC. Desde controles de máquinas simples hasta sistemas complejos de automatización industrial, las puertas lógicas determinan cómo responden los...