1 of 1

B&R 7AI774.70 B&R 2003 Analog Input Module

B&R 7AI774.70 B&R 2003 Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: 7AI774.70

  • Country of origin:ایالات متحده آمریکا

  • Product Type: Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The 7AI774.70 (7AI774.70) is a high-reliability analog input module engineered for the B&R 2003 series control system. Designed to handle four independent 0 to 20 mA current inputs with 12-bit resolution, this module is a primary choice for process automation industries, including oil and gas, chemical manufacturing, and hazardous location monitoring. By providing accurate conversion of current signals into digital data, the 7AI774.70 minimizes measurement latency and enhances the stability of control loops, effectively reducing the risk of system-wide downtime.

Technical Configuration

This module utilizes a robust 12-bit A/D conversion architecture, ensuring precise signal interpretation for process sensors. It is fully certified for use in challenging industrial environments, carrying cULus HazLoc E180196 approval for Class I, Division 2, Groups ABCD applications. This makes it an ideal solution for facilities requiring equipment that can operate safely in the presence of flammable gases or vapors.

Installation is facilitated by a screw-in modular design, allowing for efficient mounting within standard B&R 2003 rack systems. To maintain electrical safety and signal integrity, the module requires the separate purchase of a TB712 terminal block, which provides the necessary field wiring interface. The design focuses on high signal-to-noise ratios, making it highly effective when deployed alongside industrial drives and power management hardware.

Technical Specifications

Feature Specification
Model 7AI774.70
Brand B&R
Series B&R 2003
Module Type Analog Input Module
Input Channels 4
Signal Range 0 to 20 mA
Resolution 12-bit
Hazardous Location Rating Class I, Div 2, Groups ABCD
Certifications CE, UKCA, EAC, cULus HazLoc E180196
Mounting Style Screw-in module
Weight 2 kg

FAQs

Is the TB712 terminal block included with the 7AI774.70?

No, the TB712 terminal block is an essential accessory that must be ordered separately to complete your installation.

Can this module be used in non-hazardous industrial zones?

Yes, while it is certified for Class I, Division 2 hazardous locations, it is fully compatible with standard industrial control environments where such safety ratings exceed the minimum requirement.

Does the module require external power for the 0-20 mA loops?

The inputs are typically passive and expect the current loop to be driven by a transmitter or an external 24 VDC power supply routed through the field sensors.

How do I ensure the accuracy of the 12-bit signal conversion?

Accuracy is maintained by ensuring low-impedance connections at the terminal block and using properly shielded cabling to minimize current signal interference or fluctuations.

Installation and Safety Guidelines

  • Hazardous Area Compliance: When installing in Class I, Division 2 environments, ensure the module is housed within a secondary enclosure that meets local electrical codes (e.g., NEMA or IP rated). All wiring must comply with the specific requirements for hazardous locations.
  • Terminal Block Wiring: Ensure the TB712 is securely fastened to the 7AI774.70 before applying power. Torque the terminal screws to the manufacturer’s specifications to prevent intermittent connection failures, which could trigger false alarms in current loop monitoring.
  • Signal Shielding: For 0 to 20 mA signals, use high-quality shielded twisted-pair cables. Terminate the shield at the system's designated common ground point to suppress electromagnetic interference (EMI) that can cause signal jitter.
  • Loop Calibration: Periodic verification of the loop current is recommended. If readings deviate from the source output, verify that no parallel resistance or ground leakage is present in the loop wiring.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
آبی
Country of origin
ایالات متحده آمریکا

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...