1 از 1

Beckhoff EPP2338-1001 EtherCAT P Box 8-channel Digital Input/Output Module

Beckhoff EPP2338-1001 EtherCAT P Box 8-channel Digital Input/Output Module

فقط 10 قلم(های) کالا در انبار باقی مانده است
  • تولیدکننده: BECKHOFF

  • شماره محصول: EPP2338-1001

  • کشور سازنده:آلمان

  • نوع محصول: EtherCAT P I/O Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 500g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Designed for decentralized acquisition of binary signals directly on machinery, the BECKHOFF EPP2338-1001 integrates eight digital channels configurable as either inputs or outputs within a rugged, space-saving IP67 housing. Operating on the EtherCAT P protocol, this unit combines high-speed communication and 24 V DC power supplies (system/sensor supply Us and peripheral voltage Up for loads) onto a single, standardized M8 connection cable. The highly flexible configuration allows each channel to operate as either a 3.0 ms filtered digital input (conforming to EN 61131-2, type 1/3) or as a 0.5 A digital output, significantly reducing cable complexity and structural overhead in modern automation topologies.

Features

  • Configurable I/O Architecture: Eight bidirectional channels, individually assignable as digital inputs or digital outputs.
  • EtherCAT P Single-Cable Technology: Integrates fast EtherCAT communication, system power (Us), and peripheral load power (Up) in a single P-coded M8 connector.
  • Exceptional Physical Resilience: Fully sealed IP65, IP66, and IP67 industrial enclosure designed for direct mounting without an electrical control cabinet.
  • Individually Short-Circuit Proof Outputs: Each output channel provides up to 0.5 A of switching capacity, featuring independent short-circuit protection and diagnostics.
  • Robust Signal Conditioning: Inputs feature a fixed 3.0 ms filter time to suppress physical contact bounce and electromagnetic interference.

Applications

  • Decentralized robotics assembly cells and end-of-arm tooling.
  • Conveyor systems and high-sorting logistics distribution hubs.
  • Wet and harsh environments in food processing and packaging plants.
  • Direct machine-mount sensor arrays and actuator manifolds.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model Number EPP2338-1001
Protocol EtherCAT P
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Number of Channels 8 digital inputs or outputs, parameterizable
I/O Connections M8 x 1, 3-pin, A-coded
Input Specification EN 61131-2, type 1/3
Input Filter Time 3.0 ms
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (short-circuit proof)
Switching Times Typical TON: 50 microseconds, TOFF: 100 microseconds
Current Consumption (from Us) Typical 100 mA
Electrical Isolation 500 V
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Approvals CE, UL
Unit Weight 165 g
Shipping Weight (Calculated) 2.0 kg (with protective industrial packaging)

Connections and Interfaces

Connector / Pin Assignment Function / Circuit Assignment
M8 Socket P-Coded (EtherCAT P Input) Combines TxD/RxD lines and supplies Us (System/Sensor power) & Up (Peripheral load power).
M8 Socket A-Coded (I/O Channels) Pin 1: +24 V DC sensor/actuator supply; Pin 3: GND; Pin 4: Configured input or output signal.

Empirical Engineering Insights

Alternative Models & Compatibility

The EPP2338-1001 utilizes EtherCAT P, meaning it is physically and electrically incompatible with standard EtherCAT boxes (EP series with A-coded network ports). When designing a system, ensure this unit is connected directly to an EtherCAT P junction or terminal, such as the EK1300 coupler or EP9224 power distribution box. It requires TwinCAT 3.1 (or later) for complete XML configuration and online-diagnostics handling.

Application Pitfalls & Engineering Notes

A common issue in field installations is voltage drop on long EtherCAT P daisy chains. Because the M8 P-coded connector carries system power (Us) and actuator load power (Up) simultaneously, total current through a single run must not exceed 3 A. If using inductive loads on multiple output channels, always calculate the cumulative peak current to avoid triggering an under-voltage error on the Up line, which will fault the box diagnostics.

Commissioning & Wiring Tips

To guarantee IP67 integrity, unused M8 ports must be sealed with IP67-rated protective caps. When terminating the M8 P-coded network connectors, use a calibrated torque wrench set to 0.4 Nm to prevent physical thread damage and ensure watertight gasket sealing. In high vibration settings (e.g., dynamic robotic arms), loop and secure the EtherCAT P network cable with a minimum bend radius of 10x the cable outer diameter to prevent continuous physical strain on the internal solder joints of the M8 socket.

Installation Guidelines

CRITICAL WARNING: Prior to physically installing, replacing, or configuring any device in an EtherCAT P topology, isolate the main power source and ensure that no voltage is present on either the Us (System) or Up (Load) lines. Do not connect or disconnect any M8 cables under load; doing so causes electrical arcing that can permanently damage the internal sensitive communication circuitry.
1
Mounting: Mount the EPP2338-1001 directly to a flat metal frame or mounting plate. Torque the mounting screws to 1.2 Nm.
2
Network Termination: Connect the incoming EtherCAT P cable to the upper P-coded M8 input socket, and route the output to the next node.
3
I/O Termination: Connect the discrete field sensors or actuators to the 8 configurable M8 channels using 3-pin A-coded cables.
4
System Scanning: Power on the network and scan the system with the TwinCAT 3 System Manager. Configure each channel to its required functional state (input/output) under the CoE settings.
Loading product navigation…

Can the EPP2338-1001 be used on a standard EtherCAT network?

No. The module uses EtherCAT P technology, which integrates power and communication over a single P-coded cable. It is physically incompatible with standard EtherCAT boxes and must be connected to an EtherCAT P master terminal or distribution node.

How are the individual channels configured as inputs or outputs?

Channel configuration is handled in software. You can change and configure each channel parameters dynamically in the CoE (Can-over-EtherCAT) directory via TwinCAT.

What is the maximum output current supported per channel?

Each of the 8 channels can source up to 0.5 A when configured as an output. Every channel is independently short-circuit proof.

What happens if the current load on the EtherCAT P line exceeds 3 A?

Exceeding the 3 A physical limit causes a critical voltage drop on the Us/Up lines. This triggers local under-voltage diagnostics and can halt downstream bus communication.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه (به جز تعطیلات رسمی) پردازش و تحویل داده می‌شوند.


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...