Description

The Yokogawa AAI135-S03 (Replaced by AAI135-S53) is a high-performance analog input module belonging to the CENTUM VP distributed control system (DCS) series. Purpose-built to receive standard 4 to 20 mA industrial field signals, this module features an 8-channel input configuration with complete galvanic channel-to-channel isolation. The specific suffix layout designates this hardware as a standard type engineered with no explosion protection options. To ensure uninterrupted loop tracking in aggressive plant environments, the unit comes outfitted with an ISA Standard G3 chemical corrosion-resistant conformal coating option and an extended temperature endurance qualification spanning from -20 to 70 degC. Each field pathway is thoroughly isolated from both the system backplane and neighboring channels, allowing for seamless integration into high-availability, dual-redundant control system topologies.

Features

  • Deployed within the CENTUM VP control platform supporting dual-redundant hot-standby architectures.
  • Features 8 analog input channels with complete galvanic field-to-system and channel-to-channel electrical isolation.
  • Integrated transmitter power supply capability designed directly into the input circuit loops to drive 2-wire instruments.
  • Enhanced hardware durability via ISA Standard G3 conformal coating for harsh chemical or corrosive environments.
  • Extended thermal operational profile rated for steady execution from -20 up to 70 degC.
  • Supports advanced field asset diagnostics via native digital HART communication.

Applications

  • High-density process monitoring loops in refinery, petrochemical, and power generation facilities.
  • High-integrity instrumentation setups requiring dedicated channel isolation to eliminate ground loops.
  • Distributed control infrastructure positioned in aggressive, unconditioned outdoor environment spaces.
  • Safety-critical or high-availability processing lines demanding dual-redundant input configurations.

Ordering Information

Model/Suffix Code Option Specification
AAI135 Analog Input Module (4 to 20 mA, 8-channel, Isolated channels)
-S Standard type
0 (5) With no explosion protection
3 With ISA Standard G3 option and temperature (-20 to 70 degC) option

Technical Specifications

Items Specifications
Manufacturer Yokogawa
Model AAI135-S03 (Replaced by AAI135-S53)
Number of I/O channels 8-channel input, isolated channels
I/O signal 4 to 20 mA
Allowable input current 25 mA
Withstanding voltage

Between input and system: 500 V AC, for 1 minute


 

Between input channels: 500 V AC, for 1 minute

Input resistance

Power ON: 290 Ohm (at 20 mA) to 450 Ohm (at 4 mA)


 

Power OFF: 500 kOhm or larger

Allowable load resistance
Circuit-open detection
Accuracy ±16 uA
Data update period 10 ms
Transmitter power supply 15.0 V or higher (at 20 mA); 29.3 V or less (at 0 mA)
Temperature drift ±16 uA / 10 degC
Maximum current consumption 360 mA (5 V DC), 450 mA (24 V DC)
Weight 0.3 kg
External connection Pressure clamp terminal, MIL connector cable, dedicated cable
HART communication Available

Installation Guidelines

  • Align and insert the input module into its specified node backplane interface slot within the CENTUM VP rack, confirming that all backplane connectors latch with zero binding tension.
  • Maintain critical loop protection constraints: A Zener barrier is not allowed to be connected with this module. An isolation barrier must be implemented when deploying this device within intrinsically safe field loops.
  • For installations routing through a MIL connector cable interface, check that the overall application withstanding voltage limitations conform to the distinct technical boundaries of the chosen wiring cable harness.
  • Keep cabinet ventilation channels clear to permit optimal convection airflow, ensuring internal temperatures stay safely inside the designated -20 to 70 degC envelope.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa AAI135-S03 CENTUM VP Analog Input Module

Does the module support the connection of external Zener barriers?

No, a Zener barrier is not allowed to be connected with this module. An isolation barrier must be used instead when the device is deployed in intrinsically safe applications.

What are the exact channel isolation capabilities of this device?

The module features complete isolation between the field circuits and the internal system logic, as well as galvanically isolated pathways between each individual input and output channel, rated at 500 V AC for 1 minute.

How does the allowable load resistance change under high operating temperatures?

The standard allowable load resistance for the output channels is 0 to 750 Ohm. However, when the module is used in ambient temperatures from 60 to 70 degC inside a conforming ER bus node unit, the allowable load resistance adjusts to a window of 200 to 750 Ohm.

What happens to the module input resistance when the system is powered down?

When the power is ON, the input resistance varies dynamically from 290 Ohm (at 20 mA) to 450 Ohm (at 4 mA). When the power is OFF, the input resistance switches to a high impedance state of 500 kOhm or larger.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ژاپن

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...