1 of 1

IL2301-B400 | BECKHOFF | Boîtier coupleur

IL2301-B400 | BECKHOFF | Boîtier coupleur

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : IL2301-B400

  • Pays d'origine :Allemagne

  • Type de produit : Boîte de couplage

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Dimensions : 30 mm x 126 mm x 26.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed to bridge high-speed Interbus networks with local IP-Link extension modules, the Beckhoff IL2301-B400 fieldbus coupler box delivers robust decentralized control in demanding environments. This compact, IP67-rated module acts as an intelligent node that coordinates signals between the primary Interbus network and up to 120 local expansion modules via the high-speed IP-Link fiber-optic ring. By housing the control electronics within a fully sealed, mechanically resilient enclosure, the Beckhoff IL2301-B400 eliminates the need for protective electrical cabinets, enabling direct machine-mount installations in areas prone to moisture, dust, and physical vibration.

Key Features

  • Interbus Integration: Direct connection to copper Interbus-S networks via dual industrial M23 connectors (9-pin male/female).
  • IP-Link Extension Ring: Manages up to 120 extension modules with efficient 64-byte input and 64-byte output data transfers.
  • High Signal Density: Supports up to 512 digital inputs and 512 digital outputs, alongside 28 analog inputs and outputs per station.
  • Rugged Environmental Protection: Certified IP65, IP66, and IP67 ratings for reliable operation in wet, dirty, or washdown conditions.
  • KS2000 Compatibility: Diagnostic and parameter configuration facilitated through the standardized KS2000 serial interface.

Applications

  • Automotive Assembly Lines: Direct mounting on robotic arms and welding fixtures without industrial enclosures.
  • Material Handling & Conveyors: Decentralized sensor/actuator routing along extensive conveyor structures.
  • Packaging Machinery: Wet area washdown zones requiring robust dust and moisture exclusion.
  • Food & Beverage Processing: Distributed I/O setups in high-humidity zones requiring IP67 washdown performance.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model / Article Number IL2301-B400
Fieldbus Protocol Interbus (Interbus-S)
Bus Interface 1 x M23 female 9-pin, 1 x M23 male 9-pin
Control Voltage Supply 24 V DC (acceptable range 20 to 29 V DC)
Box Power Supply Current 85 mA + sensor consumption (Max. 0.5 A total)
Power Supply Connections Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Isolation Voltage Control voltage to fieldbus: None
Configuration Interface KS2000 serial interface via special connector
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
IP Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm (approximate, excluding connectors)
Weight 0.35 kg
Shipping Weight (Calculated) 0.65 kg

Power Port Connections (M8 Ports)

Pin Number Assignment Description
Pin 1 +24 V DC Control Feed for logic operations and internal box control
Pin 2 +24 V DC Load Supply for connected output channels and field devices
Pin 3 GND Control Reference potential for internal control and logic circuit
Pin 4 GND Load Reference potential for output load actuators

Empirical Engineering Insights

Alternative Models & Compatibility

The B400 variant specifically uses copper Interbus M23 interfaces. Note that Beckhoff also manufactured B408 variants with fiber optic connections. Ensure your existing cabling system matches the copper physics. If substituting older IL2301 units, confirm your local IP-Link fiber lengths; damaged or dirty IP-Link connectors can result in loss-of-link errors that are hard to diagnose over the primary Interbus diagnostics.

Application Pitfalls & Engineering Notes

While the device operates without a protective enclosure, mounting it on high-temperature machinery or in direct sunlight can cause its internal temperature to exceed the +55 degC limit. Provide protective shielding or standoffs when mounting on heat-generating surfaces. Keep track of sensor current draws on the local IP-Link expansion modules; exceeding 0.5 A total on the control power circuit will cause brownouts and communication dropped frames.

Commissioning & Wiring Tips

Always use original Beckhoff IP-Link cables and observe minimum bend radiuses. Sharp bends in plastic optical fibers (POF) result in excessive attenuation, causing sporadic I/O errors. When preparing Interbus M23 connectors, shield continuity must be run fully to the metallic connector shell to minimize high-frequency noise interference from nearby Variable Frequency Drives (VFDs).

Installation Guidelines

CRITICAL SAFETY WARNING De-energize all power sources (both Control Voltage and Load Voltage) before physically mounting or routing the M23 and M8 connectors. Hot-plugging industrial M8 or M23 connections can cause arcing, damaging sensitive optical interface drivers and corrupting EEPROM parameters.
1

Mount the coupler box directly to the machine chassis using two M4 bolts. Ensure the flat rear face is seated tightly against a clean, paint-free metal surface to maximize thermal dissipation and ground paths.

2

Insert and secure the IP-Link plastic optical fiber (POF) cable links. Ensure clean, perpendicular cuts on the fiber ends to minimize signal loss, and push the connectors in until they lock with an audible click.

3

Connect the incoming and outgoing Interbus M23 connectors, manually tightening the metal knurled rings to maintain IP67 seal integrity. Avoid utilizing power tools to tighten connectors.

4

Plug in the M8 power cables, ensuring independent routing for Control and Load voltages to minimize electromagnetic cross-talk on the sensor lines.

Loading product navigation…

How many extension modules can be run off the IL2301-B400?

The IL2301-B400 coupler box supports a maximum of 120 IP-Link fiber-optic expansion modules, with data limits of up to 64 bytes of input and 64 bytes of output.

What kind of fieldbus protocol does the B400 interface support?

The B400 interface type indicates compatibility with copper-based Interbus-S networks, utilising a 9-pin female and a 9-pin male M23 industrial connection socket.

Is the control voltage electrically isolated from the fieldbus inside the IL2301-B400?

No, there is no electrical isolation between the control voltage and the Interbus fieldbus circuit. Ensure clean reference potentials across all network nodes.

Can I configure the coupler box parameters without a PLC?

Yes, you can configure local IP-Link settings, diagnostics, and parameter lists offline via the Beckhoff KS2000 configuration software through the serial programming port.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...