1 of 1

IP1002-B518 | Beckhoff | Boîtier de bus de terrain

IP1002-B518 | Beckhoff | Boîtier de bus de terrain

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : IP1002-B518

  • Pays d'origine :Allemagne

  • Type de produit : Boîte Fieldbus

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Dimensions : 30 mm x 210 mm x 26.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for decentralized acquisition of digital signals, the Beckhoff IP1002-B518 Fieldbus Box operates as an 8-channel digital input module communicating via the CANopen protocol. This ruggedized, IP67-rated device interfaces directly with physical sensors in the field, eliminating the need for protective control cabinets and reducing wiring complexity. The module features an integrated M12 T-connector for seamless CANopen bus routing, alongside standard M8 connections for electrical power supply feed and downstream distribution.

Equipped with a 3.0 ms input filter, the IP1002-B518 digital input module guarantees reliable signal acquisition from proximity switches, limit switches, and photoelectric sensors in high-noise industrial environments. The system supports automatic baud rate detection from 10 kbaud up to 1 Mbaud, enabling straightforward integration into existing CANopen industrial networks.

Features

  • 8 digital input channels with a standard 3.0 ms filter delay.
  • Integrated CANopen interface supporting up to 16 send and 16 receive Process Data Objects (PDOs).
  • Dual M12 fieldbus connections (1 x plug, 1 x socket) with integrated T-connector functionality for daisy-chain networks.
  • Short-circuit proof sensor supply sourced directly from the control voltage (maximum 0.5 A total).
  • Diagnostic capabilities including life guarding, node guarding, emergency objects, and variable mapping.
  • Robust polyamide housing with high resistance to vibration, shock, and electromagnetic interference.

Applications

  • Distributed machinery control and conveyor automation systems.
  • Process manufacturing lines requiring machine-mount, cabinet-free I/O architecture.
  • Material handling plants utilizing CANopen network structures.
  • Automotive assembly lines and heavy-duty robotic workstations.

Technical Specifications

Manufacturer Beckhoff
Model/Part Number IP1002-B518
Product Series Fieldbus Box (IPxxxx-B51x series)
Protocol CANopen
Number of Inputs 8 digital inputs
Input Connection Type M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Delay 3.0 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 2)
Input Current Typically 6 mA (EN 61131-2, type 2)
Sensor Supply From control voltage, max. 0.5 A total (short-circuit proof)
Bus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin), integrated T-connector
Power Supply Feed 1 x M8 male socket (4-pin)
Power Supply Downstream 1 x M8 female socket (4-pin)
Current Consumption (Box) 45 mA + sensor current
Electrical Isolation Control voltage/fieldbus: 500 V
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Housing Material Polyamide PA6
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Shipping Weight 2.0 kg

Connections and Interfaces

Interface Type Connector Style Function
Fieldbus In M12 Plug, 5-pin CANopen bus entry point
Fieldbus Out M12 Socket, 5-pin Downstream CANopen connection (T-connector branch)
Power Feed M8 Male, 4-pin 24 V DC control voltage input
Power Downstream M8 Female, 4-pin Loop-through 24 V DC control voltage
Digital Inputs 1-8 M12, screw-type Sensor connection terminals

Installation Guidelines

  • Securely mount the Fieldbus Box using the two integrated 3.5 mm mounting holes designed for M3 screws.
  • To maintain IP67 environmental sealing, ensure all unused M12 and M8 ports are sealed with appropriate industrial protective caps.
  • Do not exceed the cumulative 0.5 A current limit on the sensor power supply.
  • Verify that the CANopen network termination is correctly applied at both physical ends of the communication line.
  • Keep power cabling and high-voltage transmission lines separated from the fieldbus signal line to limit electromagnetic interference.

Compliance and Certifications

  • CE: Conforms to European Union standards.
  • UL: Underwriters Laboratories listed.
  • EMC Standards: Conforms to EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission).
  • Environmental Testing: Conforms to EN 60068-2-6 (Vibration) and EN 60068-2-27 (Shock).
Loading product navigation…

What is the primary function of the Beckhoff IP1002-B518?

The Beckhoff IP1002-B518 is an 8-channel digital input module configured for CANopen fieldbus communication. It allows direct connection of up to eight digital sensors in decentralized, cabinet-free environments.

What protection class does the IP1002-B518 have?

The module has an IP65, IP66, and IP67 rating according to EN 60529, making it highly dust-proof and water-resistant for demanding industrial settings.

How does the integrated T-connector on the IP1002-B518 assist with wiring?

The integrated T-connector features one M12 plug and one M12 socket, allowing users to loop the CANopen bus directly through the module without requiring external T-pieces or complex junction blocks.

Can the input filter speed be configured?

The IP1002-B518 comes with a fixed hardware input filter of 3.0 ms to ensure robust noise suppression on all 8 digital inputs.

What are the power requirements for the sensors connected to this unit?

The sensors are powered directly from the control voltage. The module supports a maximum total sensor current of 0.5 A, which is fully short-circuit proof.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...