1 of 1

IP2300-B310 | Beckhoff | Boîte de bus de terrain

IP2300-B310 | Beckhoff | Boîte de bus de terrain

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : IP2300-B310

  • Pays d'origine :Allemagne

  • Type de produit : Boîte Fieldbus

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Dimensions : 126 mm x 30 mm x 26.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Decentralized automation tasks in harsh environments are directly addressed by the Beckhoff IP2300-B310, an IP67-rated Fieldbus Box designed to bridge field sensors and actuators directly with a PROFIBUS DP network without requiring a protective control cabinet. This space-saving module integrates four digital inputs featuring a fixed 3 ms filter alongside four short-circuit-proof digital outputs rated at 0.5 A per channel. Utilizing robust M8 circular connectors, the device minimizes cabling overhead, isolates network noise, and provides local diagnostic feedback via dedicated status LEDs for seamless diagnostics on the factory floor.

Features

  • Direct Machine Mounting: IP67-rated enclosure permits cabinet-free deployment, lowering thermal loads within main enclosures and optimizing cable runs.
  • Robust Fieldbus Connectivity: Embedded PROFIBUS DP interface supporting transmission speeds up to 12 Mbaud with automatic baud rate detection.
  • Comprehensive Digital I/O: Built with 4 digital inputs (24 V DC, 3 ms filter) and 4 digital outputs (24 V DC, 0.5 A load capacity).
  • Enhanced Circuit Protection: Output stages are short-circuit and overload protected, ensuring resilient field operations during actuator failures.
  • M8 Connector Interface: High-density, screw-lock M8 connections guarantee mechanical stability in high-vibration machinery.

Applications

  • Decentralized material handling and heavy conveyor systems.
  • Robotic end-of-arm tooling and end-effector sensor consolidation.
  • Pneumatic valve terminal control in automotive assembly areas.
  • Packaging machinery requiring distributed IP67-rated I/O architectures.

Technical Specifications

Manufacturer Beckhoff
Model Reference IP2300-B310
Product Series Fieldbus Box (IPxxxx Series)
Fieldbus Protocol PROFIBUS DP (up to 12 Mbaud)
Digital Inputs 4 channels, 24 V DC (nominal)
Input Filter Delay 3.0 ms
Digital Outputs 4 channels, 24 V DC, short-circuit proof
Max. Output Current 0.5 A per channel (2.0 A total module load)
Connection Style M8 screw-type connectors for digital channels
Control Voltage 24 V DC (-15% / +20%)
Current Consumption Approx. 40 mA from control voltage + sensor load
Protection Class IP67 (when all connection ports are sealed)
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Shipping Weight (Calculated) 0.35 kg (excluding outer shipping carton)
Package Dimensions (Calculated) 126 mm x 30 mm x 26.5 mm

Connections and Interfaces

M8 Port Pin Input Function / Assignment Output Function / Assignment
Pin 1 +24 V DC sensor supply (Us) Not connected (NC) / Reserve
Pin 3 0 V Ground (GNDs) 0 V Ground (GNDp)
Pin 4 Digital Input Signal (DI1 to DI4) Digital Output Signal (DO1 to DO4)

Alternative Models & Compatibility

This unit serves as a standard Profibus I/O module. When transitioning from older IP2300 hardware revisions, confirm the rotary address switch behavior matches your master configuration. If moving to industrial Ethernet architectures like EtherCAT, direct equivalents are available within the Beckhoff EP2308-0001 EtherCAT Box series, which features a similar I/O density and M8 form factor.

Application Pitfalls & Engineering Notes

When switching highly inductive DC loads (such as heavy pneumatic solenoids or magnetic brakes), flyback currents can degrade the internal output switches over time. While the digital outputs are electronically protected, deploying an external flyback diode directly at the inductive load terminals is recommended to maximize hardware longevity. Additionally, avoid exceeding the maximum group limit of 2.0 A total output current across all active output channels to prevent thermal shutdown of the internal driver IC.

Commissioning & Wiring Tips

The PROFIBUS DP address must be defined manually using the two decimal rotary switches protected beneath the clear threaded cap on the front of the module. To ensure the IP67 seal rating remains valid, verify that the clear cap is tightened to its proper torque specification (0.6 Nm) and that any unused M8 ports are securely sealed using standard IP67-rated protective plugs.

Installation Guidelines

CRITICAL WARNING

Isolate all power sources supplying the host control panel and field equipment before beginning physical mounting or wiring of this fieldbus module. Dangerous electrical shock risks, short-circuits, and unexpected actuator triggering may occur if connections are modified while power is active.

1

Securely mount the fieldbus box to a flat, rigid machine surface using two M4 bolts through the pre-cast mounting holes. Ensure the surface is free from sharp vibration sources.

2

Configure the desired PROFIBUS address (from 1 to 99) via the integrated rotary switches before connecting power or fieldbus cables.

3

Connect the incoming fieldbus cable to the designated PROFIBUS interface and terminate the line if the module sits at the physical end of the bus trunk.

4

Attach the M8 I/O cables, ensuring the locking collars are fully tightened to maintain the IP67 water and dust seal. Cap any unused channels immediately.

Loading product navigation…

How do you set the PROFIBUS station address on this module?

The PROFIBUS address is defined manually using two decimal rotary switches positioned beneath the protective clear cap on the front of the enclosure. The addresses range from 1 to 99.

What is the physical connection type for the I/O channels?

All eight digital input and output channels interface through standard screw-locking M8 circular connectors, offering IP67 protection when properly tightened.

What are the output protection ratings for the digital outputs?

Each digital output is individually protected against short circuits and thermal overload. The maximum continuous current per channel is 0.5 Amps, with a collective module limit of 2.0 Amps.

Can this unit function in environments exposed to moisture and dust?

Yes, when all ports are mated with IP67-compliant M8 cables or sealed with protective caps, the entire housing is rated to IP67, preventing dust and moisture ingress.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...