1 of 1

IP5109-B400 | BECKHOFF | Boîtier de bus de terrain

IP5109-B400 | BECKHOFF | Boîtier de bus de terrain

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : IP5109-B400

  • Pays d'origine :Allemagne

  • Type de produit : Boîte Fieldbus

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed to facilitate decentralized field installation, the Beckhoff IP5109-B400 offers robust distribution of digital and analog peripheral signals directly at the machine level. This module eliminates the requirement for protective enclosures by integrating an IP65/66/67 protection rating directly into its structural housing. It establishes network communication through a standard M23 bus interface and features a highly efficient loop-through power distribution architecture via integrated M8 power sockets. Configuration, diagnostics, and parameterization are managed seamlessly utilizing the specialized Beckhoff KS2000 software tool, ensuring direct integration with broader control topologies.

Features

  • Dual 9-pin M23 connectors (1 x female, 1 x male) for high-integrity bus lines.
  • Direct machine mounting with comprehensive environmental sealing up to IP67.
  • Integrated power distribution using 4-pin M8 modules for upstream feed and downstream looping.
  • Configuration and setup integration via KS2000 software platform.
  • Designed for harsh environments with certified resistance to vibration and mechanical shock.

Applications

  • Decentralized input/output collection in large-scale material handling and conveyor installations.
  • Automotive assembly lines requiring direct-mount machine control elements.
  • Packaging machinery environments subject to regular washdowns and high-moisture exposure.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model / Article Number IP5109-B400
Bus Interface 1 x M23 female socket (9-pin), 1 x M23 male socket (9-pin)
Control Voltage Supply 24 V DC (20...29 V DC)
Load Voltage Supply According to I/O type specification
Power Supply Connections Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Internal Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: No
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65/66/67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Net Weight 350 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector Reference Connector Type Function Assignment
Bus Input 9-pin M23 male socket Incoming fieldbus communication line
Bus Output 9-pin M23 female socket Downstream loop-through fieldbus connection
Power Feed 4-pin M8 male plug Primary 24 V DC control voltage input
Power Downstream 4-pin M8 female socket Loop-through 24 V DC control voltage output

Empirical Engineering Insights

Alternative Models & Compatibility

The IP5109-B400 utilizes standard Fieldbus Box architectural footprints. When replacing legacy Beckhoff IP-series modules, ensure that the GSD, EDS, or TwinCAT XML device description files in the master PLC are updated to match the specific revision and hardware configuration of this B400-variant unit to prevent network mapping mismatch faults.

Application Pitfalls & Engineering Notes

Be aware of the total power distribution path. When looping multiple modules via the M8 downstream interfaces, the aggregate sensor current draw must not exceed 0.5 A per box. Exceeding this limit leads to voltage drop-offs and potential control-side power brownouts, particularly along long daisy-chain configurations in high-vibration zones.

Commissioning & Wiring Tips

To guarantee IP67 protection integrity over life cycles, M8 and M23 connections should be tightened using a calibrated torque wrench to the exact manufacturer-specified torque values. Over-tightening can crush the internal rubber O-rings, leading to moisture ingress during high-pressure machine washdowns, while under-tightening compromises electrical contact under mechanical stress.

Installation Guidelines

CRITICAL WARNING

Ensure all power supplies feeding the M8 connection lines and control buses are physically locked out and de-energized before mounting, wiring, or configuring the device. Failure to completely isolate the power can result in system short circuits, driver damage, or localized electrical faults.

1

Verify the physical integrity of the mounting location. Ensure the surface is flat to avoid structural stress on the fiber-reinforced plastic housing of the box.

2

Secure the unit using standard mounting bolts. Route the M23 bus input and output cables without tight bends to prevent shielding breakdown and EMI issues.

3

Connect the M8 power feed and loop-through cables. Fit protective dust caps on any unused M8 or M23 ports to maintain the IP67 environmental seal.

Loading product navigation…

What is the primary power requirement for the IP5109-B400?

The module requires a 24 V DC (within a 20 to 29 V DC range) control voltage supply via its M8 male input connector.

How is the IP5109-B400 Fieldbus Box configured?

Configuration, parameter adjustments, and troubleshooting are carried out using the Beckhoff KS2000 software interface over the standard configuration path.

Does this module provide electrical isolation?

There is no electrical isolation between the internal control voltage circuits and the fieldbus communication lines on this model.

What is the environmental seal rating of this fieldbus box?

The module is rated IP65, IP66, and IP67 according to EN 60529, making it suitable for direct mounting on machines in wet, dusty, or high-washdown areas.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...