Description

Designed for decentralized, cabinet-free industrial automation, the IP5209-B200-1000 serves as a rugged Fieldbus Box module using Beckhoff Lightbus communication technology. This module enables direct connection of peripheral field signals to a centralized control network without requiring additional protective enclosures, significantly reducing wiring overhead and installation space.

The unit features twin fiber-optic sockets designed for ZS1020-0010 plugs, enabling a deterministic data transfer rate of 2.5 Mbaud. This fiber-optic interface provides complete electromagnetic immunity, making it ideal for high-noise industrial environments. System configuration is executed via the KS2000 software suite or directly through the system controller. Power routing is simplified through standard M8 connectors, with dedicated channels for control voltage and downstream loop-through distribution.

Features

  • High-speed Lightbus system integration via dual fiber-optic ports.
  • Robust IP65/66/67 physical protection for direct machine mounting.
  • Comprehensive electrical isolation between the control voltage and the fieldbus network.
  • Flexible configuration support via KS2000 software or host controller.
  • Efficient power distribution using standard M8 male/female connectors.

Applications

  • Automotive manufacturing lines and assembly systems.
  • Heavy industrial machinery and process control plants.
  • High-noise electromagnetic environments requiring fiber-optic isolation.
  • Material handling and packaging equipment.

Technical Specifications

Manufacturer Beckhoff
Part Number / Model IP5209-B200-1000
Bus Interface 2 x fiber-optic socket for plug ZS1020-0010
Data Transfer Rate 2.5 Mbaud
Control Voltage Power Supply 24 V DC (-15% / +20%)
Load Voltage Power Supply According to I/O type
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Electrical Isolation Control voltage/fieldbus: Yes; Control voltage/inputs-outputs: According to I/O type
Ingress Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Weight Approx. 250 g

Connections and Interfaces

Connector / Pin Function
Fiber-Optic Ports (2x) Lightbus communication (ZS1020-0010 connector type)
M8 Male (4-Pin) - Feed Primary 24 V DC control voltage input and load voltage feed
M8 Female (4-Pin) - Downstream Power distribution loop-through to adjacent modules

Installation Guidelines

  • Mounting Position: Variable. Secure directly to the machine frame using appropriate M4 mounting screws.
  • Grounding: Ensure a low-resistance connection between the module housing and the grounded machine chassis.
  • Fiber-Optic Handling: Observe minimum bending radius requirements for the fiber-optic cables to prevent signal attenuation or damage.
  • Connector Torque: Hand-tighten all M8 connectors to guarantee IP67 sealing integrity; do not over-torque.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What interface does the IP5209-B200-1000 use for network communication?

The module uses two fiber-optic sockets designed for ZS1020-0010 plugs, communicating via the Beckhoff Lightbus protocol.

Can this module be mounted directly on a machine without an enclosure?

Yes, it features an IP65/66/67 rating conforming to EN 60529, which makes it suitable for direct, cabinet-free machine mounting.

What is the maximum data transfer rate of the IP5209-B200-1000?

The module supports deterministic data transfer rates up to 2.5 Mbaud over the Lightbus fiber-optic connection.

How are the configuration and parameterization managed?

The device can be configured either via the Beckhoff KS2000 configuration software or directly through the primary system controller.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...