1 of 1

ZB7100-0250 | BECKHOFF | Câble EtherCAT P

ZB7100-0250 | BECKHOFF | Câble EtherCAT P

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : ZB7100-0250

  • Pays d'origine :Allemagne

  • Type de produit : Câble EtherCAT P

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Dimensions : 1 x 4 x 0.34 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Integrating both high-speed Ethernet communication and dual 24 V DC auxiliary power channels into a single mechanical sheath, the Beckhoff ZB7100-0250 simplifies decentralized machine topologies. This heavy-duty EtherCAT P cable is engineered to deliver reliable data transmission alongside system and peripheral power distribution. By utilizing a high-grade polyurethane (PUR) jacket, this cable offers robust resistance against harsh ambient oils, coolants, and continuous torsional mechanical stresses, making it ideal for highly dynamic automated production environments.

Key Features

  • One-Cable Technology (OCT): Combines 100 Mbps EtherCAT communication and separate Us/Up power lines in a single compact profile.
  • Drag-Chain Optimization: Built with highly flexible conductors designed to withstand continuous bending cycles in dynamic cable tracks.
  • PUR Sheathing: Polyurethane outer jacket provides excellent resistance to abrasion, tearing, mineral oils, and synthetic lubricants.
  • High-Visibility Identification: Standard black jacket (RAL 9005) with a distinctive red stripe (RAL 3020) for rapid identification of EtherCAT P lines in complex control panels.

Applications

  • Continuous flex drag-chains on multi-axis robotic gantries.
  • Decentralized Beckhoff EP-series IP67 I/O box modules.
  • Automotive assembly lines and packaging machine routing.
  • Material handling systems requiring distributed fieldbus distribution.

Technical Specifications

Technical Parameter Value / Specification
Manufacturer Beckhoff
Model / Article Number ZB7100-0250
Cable Type EtherCAT P (Data and Power Combined)
Ethernet Cross-Section 1 x 4 x 0.34 mm² (AWG 22)
Power Cross-Section 2 x 0.75 mm² (AWG 18)
Outer Cable Diameter 9.0 mm +/- 0.2 mm
Jacket Material Polyurethane (PUR)
Overall Shielding No overall shield (unshielded core bundle layout)
Jacket Color Black (RAL 9005) with red stripe (RAL 3020)
Suitability Drag-chain compatible
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg

Cable Core Structure

Wire Group Quantity & Size Functional Assignment
Ethernet Core Quad 4 x 0.34 mm² (AWG 22) EtherCAT data transmission (TX/RX lines)
Power Conductors 2 x 0.75 mm² (AWG 18) Us (system/sensor power) & Up (peripheral/actuator power)

Empirical Engineering Insights

Alternative Models & Compatibility

It is critical to distinguish the ZB7100-0250 from standard green-jacketed EtherCAT cabling. Standard EtherCAT lines do not carry the nested power conductors required for EtherCAT P devices. Using a standard Ethernet cable in place of an EtherCAT P cable will result in a total lack of power to downstream nodes. Ensure your field connectors are dedicated P-coded M8/M12 interfaces to avoid mechanical mismatching during field wiring.

Application Pitfalls & Engineering Notes

When routing the ZB7100-0250 in highly populated drag-chains, avoid running this unshielded-power configuration directly parallel to raw VFD motor lines or high-voltage AC cables without at least 100 mm of physical separation. Even though the EtherCAT transmission protocol is highly noise-tolerant, massive high-frequency electromagnetic fields can induce noise on the unshielded power cores, causing intermittent voltage dips on the auxiliary Us and Up rails.

Commissioning & Wiring Tips

When stripping the tough PUR jacket, use rotary cutting tools precisely adjusted to the 9.0 mm outer diameter. Because the internal signal quad relies on delicate insulation, any accidental knicking of the internal core structures during the stripping process can degrade high-frequency data characteristics, leading to cyclic redundancy check (CRC) errors in the TwinCAT system manager diagnostics.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and lock out all 24 V DC power sources feeding both the Us and Up systems before commencing termination. Connecting or disconnecting live EtherCAT P lines can generate localized micro-arcing, destroying the sensitive physical layer transceivers of adjacent network nodes.

1

Calculate the total current draw of downstream nodes on both the Us and Up power branches to ensure the AWG 18 (0.75 mm²) power wires do not exceed their thermal capacity or cause significant inline voltage drop over long runs.

2

Observe the minimum bending radius of the cable during installation within the drag chain. Ensure the cable is laid without twist and is free to move laterally in the track cavities.

3

Terminate utilizing high-quality P-coded field-assembly connectors, ensuring proper sealing to maintain the required IP67 environmental rating of the node interfaces.

Loading product navigation…
Key Features:

Can I use the ZB7100-0250 cable in standard EtherCAT installations?

This cable is specifically designed for EtherCAT P, which combines communication and power. While it can physically carry data, standard EtherCAT devices cannot access or route the integrated auxiliary power lines. Use this cable exclusively within dedicated EtherCAT P networks with P-coded connectors.

How does the PUR jacket perform in harsh environments?

The polyurethane (PUR) jacket is highly robust, providing outstanding mechanical resistance to tearing, continuous flex wear in drag chains, and chemical resistance to industrial oils, coolants, and typical factory chemicals.

What are the wire gauges used for the data and power cores?

The cable contains an Ethernet star quad consisting of four AWG 22 (0.34 mm²) conductors for high-speed data transfer, and two power conductors of AWG 18 (0.75 mm²) for auxiliary Us and Up power transmission.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...