1 de 3

Module Processeur CPU General Electric IC695CRU320

Module Processeur CPU General Electric IC695CRU320

Il ne reste que 8 article(s) en stock
  • Fabricant : General Electric

  • N° de produit : IC695CRU320

  • Pays d'origine :États-Unis

  • Type de produit : Module processeur CPU

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 680g

  • Dimensions : 35 mm x 140 mm x 135 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The IC695CRU320 is a high-performance redundancy central processing unit designed for the PACSystems RX3i platform. This control module executes real-time machine automation, process synchronization, and high-speed material handling control strategies. It communicates directly with local I/O and intelligent options over an integrated dual backplane bus architecture, merging a high-speed PCI bus for advanced throughput with a serial backplane to allow the simple migration of existing Series 90-30 modules. Operating as the primary computational engine within a Hot Standby (HSB) redundancy framework, a matched pair of these units ensures a resilient architecture that survives single-point failures with a bumpless switchover mechanism. Embedded serial channels utilize standard protocols such as SNP Slave, Modbus RTU Slave, and Serial I/O to link seamlessly with programmer terminals, operator interfaces, and distributed serial devices.

Features

  • Incorporates Hot Standby (HSB) technology supporting a fully synchronized redundant pair with online programming and component repair capabilities.
  • Provides 64 Mbytes of battery-backed user memory coupled with 64 Mbytes of non-volatile flash memory for secure application block storage.
  • Supports dual backplane bus connectivity, ensuring simultaneous electrical compliance with the PCI 2.2 specification and legacy Series 90-30 modules.
  • Delivers continuous background tracking diagnostics via a hardware logic toggle switch and an error checking and correction (ECC) single-bit correcting system.
  • Implements rapid role switching execution with a maximum logic scan switchover time of 1 scan and a minimum response time of 3.133 msec.
  • Features on-the-fly execution for up to 512 internal program blocks with a maximum individual block constraint of 128KB.

Applications

  • Critical Process Automation Systems: Providing synchronized backup configurations for chemical, water treatment, and continuous thermal process loops.
  • High-Speed Material Handling Lines: Utilizing the dual backplane PCI layer to track multi-axis sorting machinery without process disruptions.
  • Power and Infrastructure Remote Telemetry: Deploying serial SNP and Modbus networks to coordinate remote substation RTUs and plant HMIs.

Ordering Information

Catalog Number Description
IC695CRU320 RX3i 1GHz Celeron M CPU with 64MB User Memory 
IC695ACC302 Smart Auxiliary Battery for Memory Retention 
IC693ACC302 Auxiliary Battery for Memory Retention 
IC690RBT001 Rechargeable Battery for Memory Retention 

Technical Specifications

Parameter Value
Manufacturer GE Fanuc (GE Intelligent Platforms)
Model Number IC695CRU320
Series PACSystems RX3i 
Processor Type 1GHz Intel Celeron M 
User Memory Capacity 64 MB Battery-Backed RAM / 64 MB Flash User Memory 
Redundancy Type Hot Standby (HSB) 
Power Requirements (+3.3 Vdc) 1.0 Amps nominal 
Power Requirements (+5 Vdc) 1.2 Amps nominal 
Operating Temperature 0 to 60 degC (32 to 140 Fahrenheit) 
Embedded Communications RS-232, RS-485 
Serial Protocols Supported Modbus RTU Slave, SNP, Serial I/O 
Backplane Compatibility Dual Backplane Bus (RX3i PCI and high-speed serial bus) 
PCI Standards Compliance Electrically compliant with PCI 2.2 standard 
Memory Error Correction Single bit correcting and multiple bit checking (ECC) 
Maximum Data Transfer List Up to 2 Mbytes 
Maximum Program Blocks 512 blocks (128KB maximum size per block) 
Discrete Reference Tables %I and %Q: 32Kbits 
Analog Reference Tables %AI and %AQ: Configurable up to 32Kwords 
Flash Endurance Rating 100,000 write/erase cycles minimum 
Time of Day Clock Accuracy Maximum drift of 2 seconds per day 
Elapsed Time Clock Accuracy 0.01% maximum 
Estimated Weight 0.68 KG
Estimated Dimensions (W x H x D) 35 mm x 140 mm x 135 mm

Connections/Interfaces

Port Connection Function / Protocol Style
COM1 Embedded D-sub serial interface port supporting RS-232 configuration paths 
COM2 Embedded D-sub serial interface port supporting RS-485 configuration paths 

Installation Guidelines

  • Ensure the target RX3i backplane rack system is fully powered down before sliding the hardware assembly into its active chassis slot.
  • Secure the product within a closed safety enclosure providing an IP20 rating or a minimum NEMA/UL Type 1 configuration to guard against environmental pollutants.
  • When locating the system in Class I, Division 2 explosive atmospheres, verify that the containing enclosure is accessible only via specific service tool use.
  • Check that only authorized auxiliary memory batteries, such as the IC695ACC302 or IC690RBT001 packages, are attached to the module's battery interface leads.
  • Ground all structural backplanes thoroughly according to standard engineering EMI/RFI guidelines prior to putting the redundancy data links online.

Compliance and Certifications

  • Class 1 Division 2: Certified safe for use in Groups A, B, C, and D Hazardous Locations.
  • ATEX Zone 2: Approved for Zone 2, Group IIC explosive environments when mounted inside an IP54 rated enclosure.
  • EU RoHS: Compliant with EU Directive 2002/95/EC under specific Annex exemptions 7(a), 7(c)-I, and 7(c)-III.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Module Processeur CPU General Electric IC695CRU320

What core components are needed to establish a full Hot Standby redundancy layout?

A complete redundancy system requires two separate units, where each unit is equipped with one redundancy CPU and a matched redundancy Memory Xchange module configured as a synchronization link.

How does the dual backplane design handle legacy modules?

The dual backplane framework incorporates a fast PCI bus for high-throughput advanced cards alongside a serial bus layer that permits easy migration of existing Series 90-30 I/O modules.

What action is required if a nested loop error causes a control freeze in older systems?

Upgrading the device firmware version to 8.05 or later fixes known processing anomalies where the system could halt if an inner loop start point exceeded its end parameter.

What protocols are supported by the onboard serial communication channels?

The embedded serial ports natively support Modbus RTU Slave, SNP Slave, and standard Serial I/O communication protocols.

What is the maximum amount of application data that can be synchronised between the active and backup controllers?

The system supports hardware configurations and variable transfers allowing a maximum transfer list size of up to 2 Mbytes of active tracking data.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Noir
Country of origin
États-Unis
Power source
Alimenté par courant alternatif

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...