The UR6DV (UR-6DV) is a high-density digital input/output module engineered for the General Electric Universal Relay (UR) Series platform. This module serves as a critical hardware interface between external field switchgear devices and the internal processing environment of protection, control, and monitoring relays. It provides simultaneous discrete signal acquisition and heavy-duty control execution capabilities, facilitating high-speed communication over the internal backplane bus. Designed for deployment in utility substations, power generation facilities, and critical heavy industrial networks, the UR6DV ensures reliable monitoring of breaker status auxiliary contacts, disconnect switches, and external lockout systems while providing low-latency control outputs for protective tripping circuits. It functions seamlessly within modular UR chassis configurations, maintaining full compatibility with core processor modules and EnerVista orchestration software.
Plug-in form factor allowing secure mounting inside standard 19-inch UR rack enclosures
Applications
Utility substation automation and distribution system control
Circuit breaker status monitoring and automatic trip/close control loops
Disconnect switch and grounding switch position indication
Power generation plant protection systems (such as G60 or Generator Management setups)
Industrial microgrid power management and load shedding systems
Technical Specifications
Parameter
Specification
Manufacturer
GE Multilin
Country of Origin
Canada
Module Type
Digital Input / Output Module
Compatible Series
Universal Relay (UR) Series
Input Threshold Options
Configurable for 24 VDC, 48 VDC, 125 VDC, or 250 VDC utility control circuits
Operating Temperature
-40 deg C to 60 deg C
Storage Temperature
-40 deg C to 85 deg C
Relative Humidity
Up to 95% non-condensing
Surge Immunity Standard
Compliant with IEEE C37.90.1 and IEC 60255
Weight
0.85 kg
Approximate Dimensions
Standard UR Series rear slot plug-in card dimensions
Installation Guidelines
Chassis Isolation: De-energize the main UR relay chassis and completely isolate all connected external DC battery control voltage sources before inserting or removing the module.
Slot Alignment: Slide the module precisely along the plastic guide rails of the designated rear chassis slot to prevent pins on the backplane connector from bending.
Terminal Block Fastening: Secure the rear terminal block using the integral captive screws to guarantee structural stability under high-vibration conditions.
Shielding and Grounding: Ensure the overall chassis ground terminal is connected to the primary station ground bus via a low-impedance copper strap to mitigate EMI and RFI anomalies.
Cable Routing: Separate discrete control and trip circuit wiring from low-voltage communication or analog signaling paths within the enclosure panels.
FAQ
What is the primary function of the UR6DV module inside a Universal Relay chassis?
The module acts as the physical link between external discrete field components and the internal microprocessor logic, reading high-voltage status indications and executing hardware trip or close commands.
Does this module support hot-swapping while the relay is active?
No, complete isolation of the chassis power supply and external field wetting voltages is required prior to removal to avoid unintentional circuit breaker tripping or backplane communication damage.
How does the input circuitry manage high levels of electrical noise common in substations?
The digital inputs employ selectable hardware thresholds combined with programmable software debounce timers to filter out high-frequency transients, inductive coupling, and battery ground faults.
Are the contact outputs capable of directly breaking inductive circuit breaker trip currents?
Yes, the internal relays are designed with high inductive current ratings and arc suppression properties to reliably control standard utility switchgear trip coils.
Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.
Retours et garantie
Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.
Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).
Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel
Politique de remboursement et de retour
.
Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...
Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...
Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...
Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...
Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...
Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...
Choisir une sélection entraîne un rechargement complet de la page.