1 de 3

Module d'E/S numérique série UR GE Multilin UR6DV (UR-6DV)

Module d'E/S numérique série UR GE Multilin UR6DV (UR-6DV)

Il ne reste que 4 article(s) en stock
  • Fabricant : General Electric

  • N° de produit : UR-6DV

  • Pays d'origine :États-Unis

  • Type de produit : Module E/S numérique

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 850g

  • Dimensions : 8,2 cm x 12,2 cm x 6 cm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The UR6DV (UR-6DV) is a high-density digital input/output module engineered for the General Electric Universal Relay (UR) Series platform. This module serves as a critical hardware interface between external field switchgear devices and the internal processing environment of protection, control, and monitoring relays. It provides simultaneous discrete signal acquisition and heavy-duty control execution capabilities, facilitating high-speed communication over the internal backplane bus. Designed for deployment in utility substations, power generation facilities, and critical heavy industrial networks, the UR6DV ensures reliable monitoring of breaker status auxiliary contacts, disconnect switches, and external lockout systems while providing low-latency control outputs for protective tripping circuits. It functions seamlessly within modular UR chassis configurations, maintaining full compatibility with core processor modules and EnerVista orchestration software.

Features

  • High-density contact configuration optimizing chassis slot utilization
  • Hardware and software filtering on inputs to eliminate false triggers from induced AC noise or DC battery ground faults
  • Heavy-duty output relay contacts designed to handle inductive trip coil currents
  • High-speed physical contact closure execution minimizing protection loop latency
  • Plug-in form factor allowing secure mounting inside standard 19-inch UR rack enclosures

Applications

  • Utility substation automation and distribution system control
  • Circuit breaker status monitoring and automatic trip/close control loops
  • Disconnect switch and grounding switch position indication
  • Power generation plant protection systems (such as G60 or Generator Management setups)
  • Industrial microgrid power management and load shedding systems

Technical Specifications

Parameter Specification
Manufacturer GE Multilin
Country of Origin Canada
Module Type Digital Input / Output Module
Compatible Series Universal Relay (UR) Series
Input Threshold Options Configurable for 24 VDC, 48 VDC, 125 VDC, or 250 VDC utility control circuits
Operating Temperature -40 deg C to 60 deg C
Storage Temperature -40 deg C to 85 deg C
Relative Humidity Up to 95% non-condensing
Surge Immunity Standard Compliant with IEEE C37.90.1 and IEC 60255
Weight 0.85 kg
Approximate Dimensions Standard UR Series rear slot plug-in card dimensions

Installation Guidelines

  • Chassis Isolation: De-energize the main UR relay chassis and completely isolate all connected external DC battery control voltage sources before inserting or removing the module.
  • Slot Alignment: Slide the module precisely along the plastic guide rails of the designated rear chassis slot to prevent pins on the backplane connector from bending.
  • Terminal Block Fastening: Secure the rear terminal block using the integral captive screws to guarantee structural stability under high-vibration conditions.
  • Shielding and Grounding: Ensure the overall chassis ground terminal is connected to the primary station ground bus via a low-impedance copper strap to mitigate EMI and RFI anomalies.
  • Cable Routing: Separate discrete control and trip circuit wiring from low-voltage communication or analog signaling paths within the enclosure panels.

FAQ

What is the primary function of the UR6DV module inside a Universal Relay chassis?

The module acts as the physical link between external discrete field components and the internal microprocessor logic, reading high-voltage status indications and executing hardware trip or close commands.

Does this module support hot-swapping while the relay is active?

No, complete isolation of the chassis power supply and external field wetting voltages is required prior to removal to avoid unintentional circuit breaker tripping or backplane communication damage.

How does the input circuitry manage high levels of electrical noise common in substations?

The digital inputs employ selectable hardware thresholds combined with programmable software debounce timers to filter out high-frequency transients, inductive coupling, and battery ground faults.

Are the contact outputs capable of directly breaking inductive circuit breaker trip currents?

Yes, the internal relays are designed with high inductive current ratings and arc suppression properties to reliably control standard utility switchgear trip coils.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Noir
Country of origin
États-Unis
Power source
Alimentation DC

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...