1 of 1

FR-A840-00380-2-60 | Mitsubishi Electric | Onduleur FR-A800

FR-A840-00380-2-60 | Mitsubishi Electric | Onduleur FR-A800

Il ne reste que 10 article(s) en stock
  • Fabricant : Mitsubishi Electric

  • N° de produit : FR-A840-00380-2-60

  • Pays d'origine :États-Unis

  • Type de produit : Onduleur FR-A800

  • Paiement : Virement bancaire, Western Union

  • Poids : 9300g

  • Dimensions : 220 mm x 300 mm x 190 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for precise, high-performance motor control, the FR-A840-00380-2-60 is a variable frequency drive belonging to the premium Mitsubishi Electric FR-A800 series. This three-phase inverter provides dynamic vector control and high torque capability, making it well-suited for demanding heavy-duty industrial applications. Operating on a 400/415V AC input voltage, it features dual rating capabilities to maximize operating efficiency depending on load characteristics.

The unit incorporates an integrated Mitsubishi L-Series PLC with up to 6K steps of program memory, allowing users to implement decentralized control schemes directly within the drive. Backwards compatibility with the legacy FR-A700 series ensures minimal system downtime during upgrades. For communication and commissioning, the drive features a built-in USB Type A port, standard support for SSCNet, and direct plug-and-play interfacing with Mitsubishi GOT2000 HMIs.

Features

  • Real Sensorless Vector Control and Closed-Loop Vector Control up to 400 Hz.
  • Built-in Mitsubishi L-Series PLC functionality with up to 6K steps program memory.
  • Dual-rating system optimized for both Constant Torque and Variable Torque loads.
  • Optimum Excitation Control technology, reducing motor energy consumption by up to 12%.
  • Integrated temperature sensor for continuous thermal monitoring and preventative maintenance.
  • Support for external 24V DC control circuit power to maintain diagnostics and communications during main line isolation.
  • Equipped with an integrated brake chopper for effective regenerative braking up to 55kW.
  • Password-protected parameter configurations and PLC programs to safeguard intellectual property.

Applications

  • Winding and unwinding machinery requiring high-precision tension control.
  • Crane hoisting, gantry, and travel drives.
  • Machine tool spindles and high-speed positioning units.
  • Conveyor networks and continuous material handling equipment.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number FR-A840-00380-2-60
Series FR-A800
Input Voltage Range Three-phase 380 to 500 V AC, 50/60 Hz
Nominal Motor Power Rating 15 kW (ND / Heavy Duty) / 18.5 kW (LD / Normal Duty)
Rated Current Output 31 A (ND) / 38 A (LD)
Inverter Type Variable Frequency Drive (VFD)
Control Methods V/F Control, Real Sensorless Vector Control, Closed-Loop Vector Control, PM Sensorless Vector Control
Enclosure Protection Class IP20
External 24V DC Input Supported (Control circuit only)
Dimensions (W x H x D) 220 mm x 300 mm x 190 mm
Approximate Shipping Weight 9.3 kg

Installation Guidelines

When mounting the FR-A840-00380-2-60, ensure it is oriented vertically on a flat, non-flammable surface. Maintain a minimum vertical clearance of 100 mm above and below the unit, and 50 mm clearance on either side to allow proper heat dissipation from the cooling fans. Wiring must be routed inside dedicated, grounded metallic conduits to minimize electromagnetic interference (EMI). Always ensure a solid, low-impedance system ground is connected directly to the drive ground terminal.

Compliance and Certifications

  • Functional Safety: PLd (EN ISO 13849-1) and SIL2 (IEC 61508) as standard.
  • CE compliant.
  • UL listed and cUL certified.
Loading product navigation…

What is the power rating of the FR-A840-00380-2-60 inverter?

The FR-A840-00380-2-60 has a nominal power rating of 15 kW for constant torque / normal duty applications, and up to 18.5 kW for variable torque / light duty applications.

Can the control logic of this VFD be kept alive when the main power is turned off?

Yes, an external 24V DC power supply can be connected directly to the control terminals. This allows the user to access parameters, maintain communication networks, and perform safety maintenance without 400V AC main power applied.

Is there a built-in PLC in the Mitsubishi FR-A800 series?

Yes, the FR-A840-00380-2-60 features a built-in Mitsubishi L-Series PLC supporting up to 6K steps of program memory for customized local control sequences.

What is the environmental protection class of this drive?

This module features an IP20 open-chassis protection rating and must be installed inside an appropriate industrial enclosure to protect against dust and liquid ingress.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...