1 of 1

CJ1W-OD261 | Omron | Modules de sortie à transistor

CJ1W-OD261 | Omron | Modules de sortie à transistor

Il ne reste que 2 article(s) en stock
  • Fabricant : Omron

  • N° de produit : CJ1W-OD261

  • Pays d'origine :Japon

  • Type de produit : Connecteurs 40 broches

  • Paiement : Virement bancaire, Western Union

  • Poids : 2000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Providing high-density digital output capacity for CJ-series control architectures, the Omron CJ1W-OD261 module features 64 sinking (NPN) transistor outputs across a highly compact footprint. This module is engineered specifically for high-volume automated systems requiring fast response times, space efficiency, and robust switching capabilities. By utilizing two high-density 40-pin connectors, it significantly reduces the physical cabinet space required compared to traditional terminal-block-style modules, making it an ideal choice for complex, space-constrained automation panels.

Features

  • 64-Point High-Density Design: Maximizes PLC slot utilization by providing 64 individual outputs within a single standard CJ-series module width.
  • Sinking (NPN) Outputs: Tailored for switching DC loads by pulling the output signal to the 0V common line.
  • 40-Pin Connection Interface: Equipped with two 40-pin connectors to enable secure, fast pre-fabricated cable installations and reduce point-to-point wiring errors.
  • Fast Response Times: Features rapid ON/OFF response delays suitable for high-speed triggering and synchronization tasks.
  • Seamless System Integration: Fully compatible with Omron CJ1G, CJ1H, CJ1M, and NJ-series controller platforms.

Applications

  • Semiconductor manufacturing tools and sorting lines
  • High-speed packaging and filling machinery
  • Multi-axis pick-and-place assembly stations
  • Pneumatic solenoid valve manifold control
  • Indicator panels and industrial annunciator control

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number CJ1W-OD261
Module Type Basic Digital Output Unit
I/O Bus Type CJ I/O Bus
Number of Outputs 64
Output Type Transistor (NPN / Sinking)
Rated Operating Voltage 12 VDC to 24 VDC
Operating Voltage Range 10.2 VDC to 26.4 VDC
Maximum Output Current 0.3 A per point, 1.6 A per common, 6.4 A per unit
External Connections Two 40-pin MIL/Fujitsu connectors
Internal Current Consumption 170 mA at 5 VDC (from CJ-series backplane)
Net Weight 0.11 kg

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing older output systems, verify if the existing installation uses the CJ1W-OD261 (NPN sinking) or the CJ1W-OD262 (PNP sourcing). These modules are not directly interchangeable without modifying external wiring and field device configurations. The unit retains 100% form-factor compatibility with both standard CJ1 and advanced CJ2 series racks, as well as NJ/NX series remote expansion chassis.

Application Pitfalls & Engineering Notes

Ensure total load calculations take into account the 1.6 A common terminal current limit. Sinks exceeding this value under continuous operation can lead to thermal fatigue of internal trace circuits, causing localized module failures even if individual point draws are well below 0.3 A. Inductive loads like large DC solenoids or relays must be paired with external suppression diodes to eliminate back-EMF spikes that can degrade output switching transistors over time.

Commissioning & Wiring Tips

To prevent complex field-wiring debugging, it is highly recommended to use Omron's pre-fabricated G79 series connector cables coupled with dedicated XW2B or XW2D series terminal interface blocks. Using manual soldering or custom crimping on 40-pin connectors significantly increases commissioning time and introduces risk of short circuits across adjacent output channels.

Installation Guidelines

CRITICAL WARNING

De-energize all primary system power sources and lock out the main disconnect switch before inserting or removing the output module. Never insert or remove this unit while the backplane is powered. Failure to comply can result in permanent damage to the PLC CPU, backplane connections, and the internal logic circuit of the I/O module.

  1. 1
    Mounting the Module: Align the upper hook of the module housing onto the CJ-series backplane track and rotate downwards until the lower locking lever clicks firmly into place.
  2. 2
    Connecting Interface Cables: Align the keyways of the 40-pin connector on the pre-wired harness with the mating key on the module's face. Push straight in until the locking ears snap securely closed.
  3. 3
    External Power Integration: Apply external 12-24 VDC power to the dedicated power supply pins on the connector blocks. Confirm correct polarity to prevent reverse voltage protection loops from tripping.
Loading product navigation…

What connector type is required for the CJ1W-OD261 module?

This module uses two 40-pin connectors (MIL or Fujitsu standards). Connection to external field terminals is typically executed using compatible Omron pre-wired cables such as the G79 series paired with XW2B or XW2D terminal blocks.

What is the maximum output current capacity per point and per common?

Each individual output channel is rated for 0.3 A at 24 VDC. However, the total current must not exceed the limit of 1.6 A per common group and 6.4 A per unit total to prevent thermal damage.

Can this module be used with sinking or sourcing field devices?

The CJ1W-OD261 features NPN outputs, which are designed for sinking configurations. The load must be connected between the positive DC power supply line (+V) and the output channel terminal.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...