1 of 1

G9SX-ADA222-T150-RC | Omron | Unité de sécurité flexible

G9SX-ADA222-T150-RC | Omron | Unité de sécurité flexible

Il ne reste que 6 article(s) en stock
  • Fabricant : Omron

  • N° de produit : G9SX-ADA222-T150-RC

  • Pays d'origine :Japon

  • Type de produit : Unité de sécurité flexible

  • Paiement : Virement bancaire, Western Union

  • Poids : 200g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for high-performance machine safety management, the Omron G9SX-ADA222-T150-RC serves as an advanced safety controller within the Omron G9SX series. This flexible safety unit provides reliable control of safety circuits, offering both instantaneous and OFF-delayed safety outputs to accommodate complex deceleration and stopping requirements in industrial machinery. Equipped with spring-cage terminal blocks, it ensures secure, vibration-resistant connections in demanding production environments.

The unit features solid-state outputs that minimize mechanical wear and extend operational life. By providing separate pathways for instantaneous shutdown and timed deceleration, the module supports sophisticated safety logic and sequencing. It functions as an advanced main unit that can be easily integrated into distributed safety control networks.

Features

  • Advanced safety logic unit with multi-output configuration.
  • Two instantaneous safety outputs and two OFF-delayed safety outputs (P-channel MOS FET).
  • Two auxiliary PNP transistor outputs for system status monitoring and diagnostics.
  • Configurable OFF-delay time up to 150 seconds.
  • Spring-cage terminal blocks (RC type) for fast wiring and high vibration resistance.
  • Solid-state outputs reduce wear and maintenance overhead compared to electromechanical relays.
  • Clear LED diagnostic indicators on the front panel for simplified troubleshooting.

Applications

  • Emergency stop circuit monitoring.
  • Safety light curtain and safety switch integration.
  • Controlled deceleration and delayed guard interlocking systems.
  • Robotic cell gate and access door monitoring.
  • Industrial machinery requiring phased shutdown sequences.

Technical Specifications

CategorySpecification ParameterValue
Manufacturer Omron Omron
Model / Part Number G9SX-ADA222-T150-RC G9SX-ADA222-T150-RC
Series G9SX Series G9SX Series
Module Type Flexible Safety Unit (Advanced Unit) Flexible Safety Unit (Advanced Unit)
Rated Supply Voltage 24 VDC 24 VDC
Operating Voltage Range -15% to 10% of rated supply voltage -15% to 10% of rated supply voltage
Power Consumption 4 W maximum 4 W maximum
Safety Inputs Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kOhms Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kOhms
Instantaneous Safety Outputs 2 outputs (P-channel MOS FET) 2 outputs (P-channel MOS FET)
OFF-Delayed Safety Outputs 2 outputs (P-channel MOS FET) 2 outputs (P-channel MOS FET)
Auxiliary Outputs 2 outputs (PNP transistor, 100 mA max.) 2 outputs (PNP transistor, 100 mA max.)
Maximum OFF-Delay Time 150 seconds 150 seconds
Safety Output Load Current 1 A DC max. (using 2 outputs or less), 0.8 A DC max. (using 3 outputs or more) 1 A DC max. (using 2 outputs or less), 0.8 A DC max. (using 3 outputs or more)
Terminal Block Type Spring-cage terminals Spring-cage terminals
Vibration Resistance Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Weight 0.2 kg 0.2 kg

Installation Guidelines

For safe and reliable installation, adhere to the following guidelines:

  • Mounting: Mount the unit inside an IP54 or higher rated control cabinet on a standard 35 mm DIN rail. Ensure there is sufficient clearance for ventilation around the heat dissipation vents.
  • Wiring: Use solid or stranded wires with the recommended strip length for the spring-cage terminals. No tightening torque is required, but ensure the wire is fully inserted and locked.
  • Power Supply: Connect a regulated 24 VDC power supply. The DC source must provide protective separation (SELV/PELV) to comply with safety standards.
  • Grounding: Connect the functional ground terminal securely to the system's ground bar to reduce electromagnetic interference.
Loading product navigation…

What is the function of the 'RC' suffix on the G9SX-ADA222-T150-RC?

The 'RC' suffix designates that the unit is equipped with spring-cage (tension clamp) terminal blocks, which offer quick, maintenance-free wiring and excellent resistance to mechanical vibration.

What is the maximum configurable OFF-delay time for this safety unit?

This module features a maximum OFF-delay time of 150 seconds (indicated by the T150 designation).

How do the output current ratings change based on the number of active safety outputs?

When using 2 safety outputs or less, the maximum load current is 1 A DC per output. When using 3 safety outputs or more, the maximum load current is reduced to 0.8 A DC per output.

What power supply is required for the G9SX-ADA222-T150-RC?

The unit operates on a rated supply voltage of 24 VDC, with an allowable operating range of 20.4 VDC to 26.4 VDC.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...