Il ne reste que 2 article(s) en stock
  • Fabricant : Omron

  • N° de produit : NX-TS2201

  • Pays d'origine :Japon

  • Type de produit : Unité d'entrée de température

  • Paiement : Virement bancaire, Western Union

  • Poids : 70g

  • Dimensions : 12 (W) x 100 (H) x 71 (D) mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for precise thermal data acquisition in automated industrial environments, the NX-TS2201 delivers high-resolution temperature monitoring within the Omron Sysmac platform. This high-density temperature input unit supports up to two resistance thermometer (RTD) input points, processing signals from Pt100 and Pt1000 three-wire sensors. Utilizing a fast conversion cycle of 250 ms per unit and achieving a thermal resolution of 0.1 degC, it ensures stable and accurate process variables for critical control loops.

The module is built on the NX-series I/O platform, interfacing directly with NX-series CPU Units or Communication Couplers over EtherCAT or EtherNet/IP networks. To ensure high signal integrity in noisy electrical environments, the unit incorporates comprehensive galvanic isolation between individual inputs and the internal NX bus, alongside channel-to-channel isolation. Connection to field sensors is simplified through a high-reliability, 16-terminal screwless clamping terminal block.

Features

  • Two-channel high-accuracy resistance thermometer (RTD) input structure.
  • Compatible with Pt100 and Pt1000 three-wire temperature sensors.
  • Fast thermal conversion speed of 250 ms per unit.
  • Fine resolution up to 0.1 degC max for precise process monitoring.
  • Complete channel-to-channel and bus-to-channel galvanic isolation using transformer and photocoupler technologies.
  • Convenient 16-point screwless clamping terminal block reduces wiring time and maintenance overhead.
  • Supports Free-Run I/O refreshing method for consistent update intervals.

Applications

  • Industrial furnace and thermal oven control systems.
  • Food pasteurization, processing, and packaging machines.
  • Chemical and pharmaceutical reactor temperature logging.
  • HVAC, environmental chambers, and cleanroom climate control.
  • Plastic extrusion and injection molding thermal zones.

Technical Specifications

Manufacturer Omron
Part Number/Model NX-TS2201
Series NX Series I/O
Input Type Resistance Thermometer (Pt100/Pt1000, 3-wire)
Number of Inputs 2 points
Conversion Time 250 ms per Unit
Resolution 0.1 degC max.
I/O Refreshing Method Free-Run refreshing
Input Detection Current Approx. 0.25 mA
Conductor Resistance Effect 0.06 degC/Ohm max. (up to 20 Ohm max.)
External Connections 16-terminal screwless clamping block
Indicators TS status indicator
Isolation Method Between Input and NX Bus: Transformer (Power), Photocoupler (Signal)
Between Inputs: Transformer (Power), Photocoupler (Signal)
Insulation Resistance 20 MOhm min. between isolated circuits (at 100 VDC)
Dielectric Strength 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)
Power Consumption (CPU Connection) 1.25 W max. (when connected to a CPU Unit or Communication Control Unit)
Power Consumption (Coupler Connection) 0.90 W max. (when connected to a Communications Coupler Unit)
Dimensions 12 (W) x 100 (H) x 71 (D) mm
Weight 0.07 kg

Installation Guidelines

  • Mounting: Install on standard 35 mm DIN rail (IEC 60715) alongside other NX-series hardware. Ensure correct interlocking of bus connectors.
  • Warm-up Period: Allow at least 10 minutes of active operation after power-up for the internal circuitry to stabilize and achieve rated measurement accuracy.
  • Wiring: Use shielded twisted-pair cables for sensor lines. Connect the shield securely to avoid electromagnetic interference from adjacent high-voltage wiring.
  • Terminal Tooling: Use the dedicated flat-blade screwdriver or equivalent tool to actuate the screwless clamps when inserting or removing conductor wires.
Loading product navigation…

What sensor types are supported by the Omron NX-TS2201?

The NX-TS2201 temperature input unit supports Pt100 (three-wire) and Pt1000 (three-wire) resistance thermometer sensors.

What is the resolution and conversion time of this module?

The module provides a temperature resolution of 0.1 degC max. with a conversion time of 250 ms per Unit.

Does the NX-TS2201 feature isolation between individual input channels?

Yes. The module provides complete galvanic isolation using power transformers and photocoupler signal transmission both between inputs and the NX bus, and between the inputs themselves.

Does the NX-TS2201 require external I/O power supply wiring?

No. The NX-TS2201 does not utilize I/O power supply terminals and draws no current from the I/O power supply bus; it runs entirely on internal NX Unit power.

What type of connection interface does this module use?

It is equipped with a 16-terminal screwless clamping terminal block, allowing secure, tool-free field wiring.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...