1 / 1

Delta Electronics AHACABH0-5A AH Series Backplane Extension Cable

Delta Electronics AHACABH0-5A AH Series Backplane Extension Cable

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: AHACABH0-5A

  • Country of origin:Egyesült Államok

  • Product Type: PLC Extension Cables

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered to facilitate stable, high-speed data transmission across extended physical layouts, the Delta Electronics AHACABH0-5A is a specialized heavy-duty backplane extension cable. This high-integrity link is designed to connect main and active expansion backplanes within the Delta AH Series PLC automation architecture, ensuring seamless synchronization across multiple decentralized racks.

Featuring high-noise-immunity shielding and ruggedized connector interfaces, this cable maintains the signal integrity required for complex multi-rack physical configurations.

Features

  • Industrial-Grade Shielding: Built with robust electromagnetic shielding to prevent cross-talk and EMI interference on long-distance runs.
  • Heavy-Duty Connectors (HDC): Integrated heavy-duty multi-pin connectors provide extreme physical stability and vibration resistance.
  • Multi-Rack Synchronization: Enables reliable high-speed expansion bus continuity across extended hardware distances.
  • Secure Latching: Dual-metal latching mechanism prevents accidental disconnects in harsh industrial environments.

Applications

  • Decentralized Delta AH500 series PLC control topologies.
  • Multi-rack industrial control cabinets.
  • Large-scale factory floor automation requiring remote physical I/O racks.
  • Process plants with high electrical noise profiles demanding shielded bus cabling.

Technical Specifications Table

Parameter Specification
Manufacturer Delta Electronics
Model Number AHACABH0-5A
Cable Type Heavy-Duty Backplane Extension Cable (HDC)
Compatible PLC Series Delta AH Series (AH500)
Cable Length 80.0 m
Compatible Backplane Modules AHBP04M1-5A, AHBP06M1-5A, AHBP08M1-5A, AHBP12M1-5A, AHBP06E1-5A, AHBP08E1-5A
Shipping Weight (Calculated) 1.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The AHACABH0-5A extension cable is specifically matched to the Delta AH Series backplanes using the dedicated 5A-suffix expansion ports. It cannot be used with standard D-sub or RJ-45-based expansion setups from older DVP series lines. When upgrading existing legacy racks, verify that the bus termination settings on your main and active extension backplanes are configured to support long-distance extension.

Application Pitfalls & Engineering Notes

Running an 80m backplane expansion bus requires careful routing strategy. Do not run this cable parallel to high-current AC motor supply lines or variable frequency drive (VFD) output cables. Although the cable is heavily shielded, high-frequency common-mode noise on the factory floor can cause communication dropouts, resulting in intermittent backplane sync faults on the CPU.

Commissioning & Wiring Tips

Ensure the minimum bending radius of the cable is respected throughout the conduit paths. Severe bends can degrade high-frequency impedance, causing data transmission errors on the expansion bus. Ensure both connector shells are cleanly grounded through the chassis bracket grounding lugs.

Installation Guidelines

CRITICAL WARNING

De-energize all system power (main CPU rack and remote expansion rack power supplies) before connecting or disconnecting the AHACABH0-5A cable. Connecting this cable while the backplanes are live can result in transceiver damage, hardware errors, or erratic CPU behavior.

1

Route the cable along dedicated low-voltage instrument cable trays, avoiding close physical proximity to high-voltage power paths.

2

Align the pin guide keys of the heavy-duty connector with the mating port on the main CPU backplane extension interface.

3

Push the connector firmly into place until it is fully seated, then engage the metal security latches to lock the assembly physically.

4

Repeat the process for the active expansion backplane side, then power up the remote rack prior to initializing the main CPU rack.

Can the AHACABH0-5A cable be connected while the system is powered?

No. The extension backplane cable must never be connected or disconnected while the system is energized. Doing so can cause communication bus faults, CPU halts, or physical damage to the transceivers.

Which Delta backplanes are compatible with this cable?

This cable is compatible with Delta AH Series backplane models including AHBP04M1-5A, AHBP06M1-5A, AHBP08M1-5A, AHBP12M1-5A, AHBP06E1-5A, and AHBP08E1-5A.

What is the primary benefit of the heavy-duty connector (HDC) on this cable?

The heavy-duty connector design provides secure mechanical dual-latch locking and environmental protection, preventing signal degradation caused by intense industrial vibrations and moisture.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...