1 dari 1

BECKHOFF ER2028-1032 EtherCAT Box Digital Output Module

BECKHOFF ER2028-1032 EtherCAT Box Digital Output Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: ER2028-1032

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT Boxes

  • Pembayaran: T/T, Western Union

  • Berat: 950g

  • Dimensi: 60 mm x 150 mm x 26.5 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Direct field-level control of high-current actuators is executed efficiently using the Beckhoff ER2028-1032 EtherCAT Box. Housed in a highly durable, zinc die-cast enclosure, this distributed I/O module features 8 digital outputs designed to switch electrical loads directly in demanding industrial environments. By mounting directly onto machines or process equipment, the module eliminates the need for protective control cabinets, reducing wiring overhead and simplifying system topology.

The ER2028-1032 provides up to 2.8 A of output current per channel, making it ideal for driving heavier loads such as solenoid valves, contactors, auxiliary relays, small motors, and signaling devices. It interfaces seamlessly with EtherCAT networks using M12 industrial connections, offering high-speed real-time communication, robust diagnostics, and channel-level short-circuit protection to ensure continuous system availability.

Features

  • Provides 8 robust digital outputs (24 V DC) supporting resistive, inductive, and lamp loads.
  • Delivers up to 2.8 A per channel with an aggregate sum current limit of 16 A.
  • Individually short-circuit proof outputs protect system electronics from field faults.
  • Utilizes heavy-duty M12 (A-coded) connectors for secure output cabling.
  • Features high-speed EtherCAT interface via 4-pin, D-coded M12 sockets.
  • Rugged zinc die-cast housing ensures protection under severe physical and environmental stress.
  • Integrated 7/8" power connectors facilitate straightforward supply daisy-chaining.

Applications

  • Automotive assembly lines and robotic weld cells.
  • Conveyor networks, sorting systems, and material handling machinery.
  • Packaging, food processing, and bottling plants requiring washdown protection.
  • Direct machine-mounted actuator control in heavy industrial processing.

Technical Specifications

ManufacturerPart Number / ModelProtocolNumber of OutputsNominal Output VoltageMax. Output CurrentLoad Types SupportedSwitching TimesShort-Circuit CurrentBus InterfaceOutput ConnectionsPower Supply ConnectionCurrent Consumption (US)Auxiliary Power Current (UP)Electrical IsolationDimensions (W x H x D)WeightHousing MaterialProtection RatingOperating TemperatureStorage TemperatureVibration/Shock ResistanceEMC Immunity/Emission
Beckhoff
ER2028-1032
EtherCAT
8 digital outputs
24 V DC (-15% / +20%)
2.8 A per channel (individually short-circuit proof, max. sum 16 A)
Ohmic (resistive), inductive, lamp loads
Typical TON: 200 microseconds, Typical TOFF: 200 microseconds
Typical 15 A
2 x M12 sockets, 4-pin, D-coded
M12 x 1, 5-pin, A-coded (1 output per M12 plug)
Feed: 1 x 7/8" plug (5-pin); Downstream: 1 x 7/8" socket (5-pin)
Typical 130 mA from EtherCAT system voltage
Typical 20 mA + load current
500 V
60 mm x 150 mm x 26.5 mm
Approx. 950 g
Zinc die-cast
IP65, IP66, IP67 (conforms to EN 60529)
-25 degC to +60 degC
-40 degC to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Connection Type Connector Style Pin/Signal Assignment Function
EtherCAT Input / Output 2 x M12, 4-pin, D-coded Transmit and Receive data lines for high-speed communication.
Digital Outputs (1 to 8) M12, 5-pin, A-coded Dedicated channel output pin, ground, and protective earth connection.
Power Infeed 1 x 7/8" Plug, 5-pin 24 V DC system supply (US) and 24 V DC peripheral/actuator supply (UP).
Power Downstream 1 x 7/8" Socket, 5-pin Loop-through supply connection for downstream EtherCAT Box modules.

Installation Guidelines

  • Mounting: Secure the zinc die-cast module directly to a flat machine surface using 2 fixing holes for M3 screws (3.5 mm diameter) or 2 fixing holes for M4 screws (4.5 mm diameter).
  • Grounding: Ensure the metallic housing has a low-impedance connection to the machine ground/PE to maintain EMC immunity.
  • Connector Torque: Tighten all M12 and 7/8" connectors to the manufacturer-specified torque to guarantee IP67 protection against moisture and dust ingress. Put protective caps on any unused ports.
  • Cable Routing: Avoid routing communication cables parallel to high-voltage AC power lines to prevent electromagnetic interference.

Compliance and Certifications

  • CE
Loading product navigation…

What is the maximum output current limit of the Beckhoff ER2028-1032?

Each of the 8 digital output channels can handle up to 2.8 A individually. However, the total combined sum current of all channels must not exceed 16 A.

Does the ER2028-1032 require a separate control cabinet for installation?

No. Thanks to its robust zinc die-cast housing and IP65/66/67 protection ratings, it can be mounted directly on the machine or within the process environment without an enclosure.

What connector types are used for power supply connections?

The module uses standard 7/8" 5-pin connections, featuring one plug for incoming power feed and one socket for downstream daisy-chaining to additional modules.

Are the outputs protected against overcurrent and short circuits?

Yes, each output channel is individually short-circuit proof with a typical short-circuit current limit of 15 A.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...