Engineered for high-density space conservation in control cabinets, the BECKHOFF KL1889 is a High-Density (HD) Bus Terminal featuring sixteen digital inputs in a compact 12 mm housing width. Operating with negative switching (sink) logic, this module incorporates 1-wire connection technology, allowing direct connection of sensors and signals to the process image without excessive terminal blocks. Designed for seamless integration into K-bus networks, the KL1889 enables efficient signal acquisition in restricted spaces while simplifying wiring and minimizing hardware requirements.

Features

  • Provides 16 digital inputs within a compact 12 mm mechanical footprint.
  • Utilizes negative switching (sink) logic configuration.
  • Employs 1-wire connection technology with direct plug-in connection for solid conductors.
  • Tool-free termination for solid conductors; simple spring actuation by screwdriver for stranded wires and ferrules.
  • Integrated hardware input filter (typ. 3.0 ms) to suppress line bounce and noise.
  • Complete 500 V galvanic isolation between the internal K-bus and the field potential.
  • Address-free configuration for immediate plug-and-play installation within the Bus Coupler process image.

Applications

  • Space-constrained decentralized control systems and distribution cabinets.
  • Automated assembly systems, packaging machinery, and material handling lines.
  • Sensor signal concentration in industrial process automation.
  • General manufacturing and PLC I/O expansion environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model KL1889
Connection Technology 1-wire
Specification Negative switching (sink)
Number of Inputs 16
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage 18 to 30 V
"1" Signal Voltage 0 to 7 V
Input Filter typ. 3.0 ms
Input Current typ. 3 mA
Current Consumption (K-bus) typ. 20 mA
Current Consumption (Power Contacts) typ. 4 mA + load
Electrical Isolation 500 V (K-bus to field potential)
Bit Width in Process Image 16 inputs
Conductor Connection (Solid) Direct plug-in technique (0.08 to 1.5 mm²)
Conductor Connection (Stranded) Spring actuation by screwdriver (0.25 to 1.5 mm²)
Conductor Connection (Ferrule) Spring actuation by screwdriver (0.14 to 0.75 mm²)
Weight approx. 55 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Connections and Interfaces

Connection Type Conductor Type Cross-section Range
Direct Plug-In Solid Wire 0.08 to 1.5 mm²
Screwdriver Spring Actuation Stranded Wire 0.25 to 1.5 mm²
Screwdriver Spring Actuation Ferrule 0.14 to 0.75 mm²

Installation Guidelines

  • Ensure the system power supply is completely disconnected before mounting or removing the terminal.
  • Mount the module onto a standard 35 mm DIN rail (EN 60715) with vertical or horizontal mounting orientation as required.
  • Ensure the side locking mechanism of the bus terminal engages correctly with adjacent terminals to secure reliable K-bus and power contact transmission.
  • Utilize appropriate shielding and grounding procedures for sensor lines to prevent electromagnetic interference from distorting input signals.

Compliance and Certifications

  • CE
  • UL
  • Ex
  • GL
Loading product navigation…

What is the signal logic used by the BECKHOFF KL1889?

The KL1889 uses negative switching (sink) logic with 16 digital inputs.

What type of connection technology does the KL1889 support?

The module utilizes 1-wire connection technology, allowing direct conductor routing for digital signals with minimal wiring overhead.

Does the KL1889 require software addressing during setup?

No, the KL1889 is address-free and does not require software configuration; it integrates automatically into the K-bus process image.

What are the allowed conductor types and sizes for connection?

It supports solid wire (0.08 to 1.5 mm²), stranded wire (0.25 to 1.5 mm²), and ferrules (0.14 to 0.75 mm²).

What is the IP rating of the KL1889 housing?

The KL1889 has an IP20 protection class and must be installed within an appropriate control cabinet or enclosure.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...